"skb" is alway non-null here, but even if it were null the check isn't
needed because dev_kfree_skb() can handle it.
This eliminates a smatch warning about dereferencing a variable before
checking that it is non-null.
Signed-off-by: Dan Carpenter <error27@gmail.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds error checking of ctrlmode values for CAN devices. As
an example all availabe bits are implemented in the mcp251x driver.
Signed-off-by: Christian Pellegrin <chripell@fsfe.org>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
To prevent the CAN drivers to operate on invalid socketbuffers the skbs are
now checked and silently dropped at the xmit-function consistently.
Also the netdev stats are consistently using the CAN data length code (dlc)
for [rx|tx]_bytes now.
Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Acked-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
A valid CAN dataframe can have a data length code (DLC) of 0 .. 8 data bytes.
When reading the CAN controllers register the 4-bit value may contain values
from 0 .. 15 which may exceed the reserved space in the socket buffer!
The ISO 11898-1 Chapter 8.4.2.3 (DLC field) says that register values > 8
should be reduced to 8 without any error reporting or frame drop.
This patch introduces a new helper macro to cast a given 4-bit data length
code (dlc) to __u8 and ensure the DLC value to be max. 8 bytes.
The different handlings in the rx path of the CAN netdevice drivers are fixed.
Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Only files where David Miller is the primary git-signer.
wireless, wimax, ixgbe, etc are not modified.
Compile tested x86 allyesconfig only
Not all files compiled (not x86 compatible)
Added a few > 80 column lines, which I ignored.
Existing checkpatch complaints ignored.
Signed-off-by: Joe Perches <joe@perches.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
In 2.6.32-rc the new EMS USB CAN driver was contributed and added the Kconfig
entry right behind an entry of the same *vendor*. This teared the SJA1000
based driver selection into pieces.
This fix cleans up the 2.6.32-rc Kconfig files for the CAN drivers and moves
the SJA1000 and USB Kconfig portions into the belonging directories.
As there are many new CAN drivers in the queue getting this cleanup into
2.6.32-rc would massively reduce the problems for the upcoming drivers.
Thanks,
Oliver
Signed-off-by: Oliver Hartkopp <oliver@hartkopp.net>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
CPC-USB is using a ARM7 core with little endian byte order. The "id" field
in can_msg needs byte order conversion from/to CPU byte order.
Signed-off-by: Sebastian Haas <haas@ems-wuensche.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch makes the private functions alloc_can_skb() and
alloc_can_err_skb() of the at91_can driver public and adapts all
drivers to use these. While making the patch I realized, that
the skb's are *not* setup consistently. It's now done as shown
below:
skb->protocol = htons(ETH_P_CAN);
skb->pkt_type = PACKET_BROADCAST;
skb->ip_summed = CHECKSUM_UNNECESSARY;
*cf = (struct can_frame *)skb_put(skb, sizeof(struct can_frame));
memset(*cf, 0, sizeof(struct can_frame));
The frame is zeroed out to avoid uninitialized data to be passed to
user space. Some drivers or library code did not set "pkt_type" or
"ip_summed". Also, "__constant_htons()" should not be used for
runtime invocations, as pointed out by David Miller.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch allows the CAN controller driver to define the number of echo
skb's used for the local loopback (echo), as suggested by Kurt Van
Dijck, with the function:
struct net_device *alloc_candev(int sizeof_priv,
unsigned int echo_skb_max);
The CAN drivers have been adapted accordingly. For the ems_usb driver,
as suggested by Sebastian Haas, the number of echo skb's has been
increased to 10, which improves the transmission performance a lot.
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: Kurt Van Dijck <kurt.van.dijck@eia.be>
Signed-off-by: David S. Miller <davem@davemloft.net>
This patch adds support for one channel CAN/USB interace CPC-USB/ARM7 from
EMS Dr. Thomas Wuensche (http://www.ems-wuensche.com).
Signed-off-by: Sebastian Haas <haas@ems-wuensche.com>
Signed-off-by: Wolfgang Grandegger <wg@grandegger.com>
Signed-off-by: David S. Miller <davem@davemloft.net>