The previous implementation registered a pointer towards hid-core
to the value of contact count. This is not safe and may be difficult
to debug if hid-core ever changes its implementation.
The use of regular indexes is a better choice.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
By running a test on all the traces of the devices I have,
I noticed that the class MT_CLS_ALWAYS_TRUE could handle all
the devices I've seen so far without any other quirks.
I guess this is the behavior Win 7 requires in its driver.
We can change the default class then and keep the existing classes
for backward compatibility and performances for some of them.
Two operations have been done:
* replaced MT_CLS_DEFAULT by MT_CLS_NSMU
* then replaced MT_CLS_ALWAYS_TRUE by MT_CLS_DEFAULT
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The previous protocol was nearly working, but when several fingers were
present on the sensor, those that were not moving were not updated
in the next report, introducing a lot of releases.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Conflicts:
drivers/hid/hid-multitouch.c
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Cando 2087:0a02 was broken, this fixes it.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Since the inclusion of this device in hid-multitouch, the device
did not forward any events. Using the serial class makes it working
again.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The serial protocol makes contact count a redondant information, and
sometimes it is not reliable (TRS-Star are in this case).
Disabling the use of contact count for these devices is thus safer.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The Sharp LC-20FE1-W screen (04dd:9681) behaves like the Nexio 42".
It may report out of ranges values that are filtered out by relying
on the Contact Count HID field.
Adding the quirk MT_QUIRK_CONTACT_CNT_ACCURATE makes hid-multitouch
strongest against this kind of device, without breaking the current
devices.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This device is the worst device I saw. It keeps TipSwitch and InRange
at 1 for fingers that are not touching the panel.
The solution is to rely on the field ContactCount, which is accurate
as the correct information are packed at the begining of the frame.
Unfortunately, CountactCount is most of the time at the end of the report.
The solution is to pick it when we have the whole report in raw_event.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Nexio 42" devices requires to rely on the HID field Contact
Count to compute the valid values. However, this field is
most of the time at the end of the report, meaning that we
need to get the all report parsed before processing it.
This patch does not introduce functional changes.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Use the new module_hid_driver macro in all HID drivers that have
a simple register/unregister init/exit.
This also converts the hid drivers that test for a failure of
hid_register_driver() and report the failure. Using module_hid_driver
in those drivers removes the failure message.
Signed-off-by: H Hartley Sweeten <hsweeten@visionengravers.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The Win 8 protocol specify the fact that each valid touch must be reported
within a frame until it is released.
We can therefore use the always_valid quirk and dismiss reports when we see
duplicate contacts ID.
We recognize Win8 certified devices from their vendor feature 0xff0000c5
where Microsoft put a signed blob in the report to check if the device
passed the certification.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 devices supporting hovering must provides InRange HID field.
The information that the finger is here but is not touching the surface
is sent to the user space through ABS_MT_DISTANCE as required by the
multitouch protocol.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This quirk allows a device to reuse a contact id when sending garbage
inactive contacts at the end of a report.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win 8 device specification changed the requirements for the hid usages
of the multitouch devices. Now InRange is optional and must be only
used when the device supports hovering.
This ensures that the quirk ALWAYS_VALID is taken into account and
also ensures its precedence over the other VALID* quirks.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 input specification clarifies the X and Y sent by devices.
It distincts the position where the user wants to Touch (T) from
the center of the ellipsoide (C). This patch enable supports for this
distinction in hid-multitouch.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 devices are required to present the feature "Maximum Contact Number".
Fortunately all win7 devices I've seen presents this feature.
If the current value is 0, then, the driver can get the actual supported
contact count by refering to the logical_max.
This win8 specification ensures that logical_max may not be above 250.
This also allows us to detect when devices like irtouch or stantum reports
an obviously wrong value of 255.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Acked-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Win8 certification introduced the ability to transmit two X and two Y per
touch. The specification precises that it must be used in an array.
This test guarantees that we split the touches on the last element
in this array.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Reviewed-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Exporting the function allows us to calculate the resolution in third
party drivers like hid-multitouch.
This patch also complete the function with additional valid axes.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Fix maxcontacts problem for PWT GeneralTouch multi-touchscreen.
Our device didn't contain HID_DG_CONTACTMAX usage. This usage use to describe
touchscreen's maxcontacts for hid-multitouch.c to get maxcontacts automatic. We
fix the device that driver can get maxcontact from our device, hence it doesn't
need .maxcontact=10. Now there is just one device class can fix all our PWT
touchscreen.
Signed-off-by: Xianhan Yu <aroundight77@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Fix the touch-up no response problem on GeneralTouch twofingers touchscreen and
modify the driver for new GeneralTouch PWT touchscreen.
Signed-off-by: Xianhan Yu <aroundight77@gmail.com>
Reviewed-by Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Add support for the Flatfrog Multitouch 3200 panel. This panel
advertises some fields that it does not use, hence the new quirk.
Cc: Pablo Cases <pablo.cases@flatfrog.com>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Some devices report the number of contacts via the unreliable
CONTACTCOUNT usage, rather than using the CONTACTMAX feature.
Without this patch, the 3M devices are constrained to the default
maximum of ten fingers.
Cc: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
With the input_mt_sync_frame() function in place, there is no longer
any need to keep the full touch state in the driver. This patch
removes the slot state and replaces the lookup code with the input-mt
equivalent.
Reviewed-and-tested-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
With the input_configured() callback in place, the setup and frame
synchronization can be simplified. The input device initialization is
moved to mt_input_configured(), to make sure the full HID report has been
seen.
Reviewed-and-tested-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Jiri Kosina <jkosina@suse.cz>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Preparing to move more repeated code into the mt core, add a flags
argument to the input_mt_slots_init() function.
Reviewed-and-tested-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Tested-by: Ping Cheng <pingc@wacom.com>
Acked-by: Dmitry Torokhov <dmitry.torokhov@gmail.com>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Add ELAN production request when resume.
Some Elan legacy devices require SET_IDLE to be set on resume.
It should be safe to send it to other devices too.
Tested on 3M, Stantum, Cypress, Zytronic, eGalax, and Elan panels.
Suggested by Benjamin Tissoires <benjamin.tissoires@enac.fr>
Signed-off-by: Scott Liu <scott.liu@emc.com.tw>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
A null test was left behind during the autoloading work;
the test was introduced by 8d179a9e, but was never completely
reverted.
Reported-by: Dan Carpenter <dan.carpenter@oracle.com>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Zytronic panels shows a new way of setting the Input Mode feature.
This feature is put in the second usage in the HID feature, instead
of the first, as the majority of the multitouch devices.
This patch adds a detection step when the feature is presented to know
where the feature is located in the report. We can then trigger the right
command to the device. This removes the magic number "0" in the function
mt_set_input_mode.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Since Henrik's autoloading changes, the proper macro for device
entry is MT_USB_DEVICE().
Reported-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Add support for a Novatek touchscreen panel as a generic HID multitouch
panel.
Signed-off-by: Austin Hendrix <ahendrix@willowgarage.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
The previous implementation introduced a randomness in the splitting
of the different touches reported by the device. This version is more
robust as we don't rely on hi->input->absbit, but on our own structure.
This also prepares hid-multitouch to better support Win8 devices.
[Jiri Kosina <jkosina@suse.cz>: fix build]
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Baanto device entry needs to be altered in the same way other device
entries have been changed in 2c2110e90b ("HID: hid-multitouch: Only match
MT interfaces").
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
I am merging multitouch branch into device-groups so that support
for Baanto device can be adjusted accordingly to the new autoloading
patches.
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
All known hid-multitouch devices currently match any device group.
However, some devices present interfaces belonging to different groups,
resulting in a race between the hid-generic and hid-multitouch modules.
This patch narrows the MT device list to match only HID_GROUP_MULTITOUCH,
which solves the problem.
As an exception, the USB_DEVICE_ID_CYPRESS_TRUETOUCH panel is not
modified, in order to suppress the unwanted extra interfaces of the
device.
Reported-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Reviewed-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Switch the driver over to device group handling. By adding the
HID_GROUP_MULTITOUCH group to hid-core, hid-generic will no longer
match multitouch devices. By adding the HID_GROUP_MULTITOUCH entry to
the device list, hid-multitouch will match all unknown multitouch
devices, and udev will automatically load the module.
Since HID_QUIRK_MULTITOUCH never gets set, the special quirks handling
can be removed. Since all HID MT devices have HID_DG_CONTACTID, they
can be removed from the hid_have_special_driver list.
With this patch, the unknown device ids are no longer NULL, so the code
is modified to check for the generic entry instead.
Signed-off-by: Henrik Rydberg <rydberg@euromail.se>
Acked-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Adds multitouch support for the Gametel Android game controller.
The multitouch events are emulated by the Gametel device. Each physical button
is configured to generate a MT event on a specific coordinate. This seems to be
the only way for us to support Android games that doesn't support HID gamepads.
It is possible to inject MT events at Android level, but this requires root on
the phone.
Signed-off-by: Andreas Nielsen <eas@svep.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
Microsoft's documentation about multitouch protocols tells that
if a device presents one touch per report, then it should be treated
as a serial protocol.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
When the quirk HID_QUIRK_MULTITOUCH is present and when hid-multitouch
is loaded, let's pass the device to hid-multitouch even if it has
not been registered in hid-multitouch.
If any other driver wants to take precedence over hid-multitouch,
the usual way of adding it to hid_have_special_driver will work as
the quirk HID_QUIRK_MULTITOUCH won't be set by the generic hid layer.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
LG multitouch panels, such as the one found in Dell ST2220T, has buggy
reports descriptors. With the previous implementation, it was impossible
to rely on the reports descriptors to determine how the different
touches are emitted from the device.
This patch changes the splitting of the different touches in the report
in a more robust way.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@gmail.com>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This is a list of devices that should be handled by hid-multitouch. They all
present the HID usage "Contact ID" and won't be handled by hid-input. Some of
them have _not_ been tested (though I have their report descriptors), but I've
been guaranted by eeti that they follow the same protocol. The tested ones are
also blacklisted in hid-core.c.
Signed-off-by: Benjamin Tissoires <benjamin.tissoires@enac.fr>
Acked-by: Henrik Rydberg <rydberg@euromail.se>
Signed-off-by: Jiri Kosina <jkosina@suse.cz>