This patch adds support for the Kvaser Leaf v2 and Leaf usb mini
PCIe card.
Signed-off-by: Olivier Sobrie <olivier@sobrie.be>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
On some Kvaser hardware, the firmware returns extra messages after the
request for card info. For instance on a Leaf Light v2:
--> CMD_GET_CARD_INFO
<-- CMD_USB_THROTTLE
<-- CMD_GET_CARD_INFO2
<-- CMD_GET_CARD_INFO_REQ
When it happens, the probing function fails because we only read
the first usb message.
To overcome this issue, we add a mechanism of retries to the
kvaser_usb_wait_msg() function.
I tested this patch with the following hardware:
- Kvaser Leaf Light
- Kvaser Leaf Light v2
- Kvaser USBCan R
This patch is necessary for the Leaf Light v2 hardware.
Signed-off-by: Olivier Sobrie <olivier@sobrie.be>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
My objective is to be able to totally discriminate CAN ports on multi-port
cards via udev so as to rename them to semantically interesting/unique names
for my system (e.g., "ecuCAN" and "auxCAN" instead of "can0" and "can1").
The following patch assigns the dev_id field to match the channel number on all
multi-channel devices. I can only test my two-port Peak PCI card, but it works
as expected: ATTRS{dev_id} now expresses the port number and my udev rules now
unambiguously pick out and rename my individual CAN ports.
Signed-off-by: Christopher R. Baker <cbaker@rec.ri.cmu.edu>
Tested-by: Oliver Hartkopp <socketcan@hartkopp.net> [PEAK PCAN-USB pro and EMS PCMCIA]
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
CAN interfaces only support MTU values of 16 (CAN 2.0) and 72 (CAN FD).
Setting the MTU to other values is pointless but it does not really hurt.
With the introduction of the CAN FD support in drivers/net/can a new
function to switch the MTU for CAN FD has been introduced.
This patch makes use of this can_change_mtu() function to check for correct
MTU settings also in legacy CAN (2.0) devices.
Signed-off-by: Oliver Hartkopp <socketcan@hartkopp.net>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
It is needed to check the number of channels returned by the HW because it
cannot be greater than MAX_NET_DEVICES otherwise it will crash.
Signed-off-by: Olivier Sobrie <olivier@sobrie.be>
Cc: linux-stable <stable@vger.kernel.org>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
None of these files are actually using any __init type directives
and hence don't need to include <linux/init.h>. Most are just a
left over from __devinit and __cpuinit removal, or simply due to
code getting copied from one driver to the next.
This covers everything under drivers/net except for wireless, which
has been submitted separately.
Signed-off-by: Paul Gortmaker <paul.gortmaker@windriver.com>
Signed-off-by: David S. Miller <davem@davemloft.net>
Some devices, like the Kvaser Memorator Professional, have several bulk in
endpoints. Only the first one found must be used by the driver. The same holds
for the bulk out endpoint. The official Kvaser driver (leaf) was used as
reference for this patch.
Cc: linux-stable <stable@vger.kernel.org>
Signed-off-by: Olivier Sobrie <olivier@sobrie.be>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
Unlike Kvaser Leaf light devices, some other Kvaser devices (like USBcan
Pro, USBcan R) receive CAN messages in CMD_LOG_MESSAGE frames. This
patch adds support for it.
Cc: linux-stable <stable@vger.kernel.org> # >= v3.8
Signed-off-by: Jonas Peterson <jonas.peterson@gmail.com>
Signed-off-by: Olivier Sobrie <olivier@sobrie.be>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>
alloc failures already get standardized OOM
messages and a dump_stack.
Signed-off-by: Joe Perches <joe@perches.com>
Acked-by: Marc Kleine-Budde <mkl@pengutronix.de>
Signed-off-by: David S. Miller <davem@davemloft.net>
This driver provides support for several Kvaser CAN/USB devices.
Such kind of devices supports up to three CAN network interfaces.
It has been tested with a Kvaser USB Leaf Light (one network interface)
connected to a pch_can interface.
The firmware version of the Kvaser device was 2.5.205.
List of Kvaser devices supported by the driver:
- Kvaser Leaf Light
- Kvaser Leaf Professional HS
- Kvaser Leaf SemiPro HS
- Kvaser Leaf Professional LS
- Kvaser Leaf Professional SWC
- Kvaser Leaf Professional LIN
- Kvaser Leaf SemiPro LS
- Kvaser Leaf SemiPro SWC
- Kvaser Memorator II HS/HS
- Kvaser USBcan Professional HS/HS
- Kvaser Leaf Light GI
- Kvaser Leaf Professional HS (OBD-II connector)
- Kvaser Memorator Professional HS/LS
- Kvaser Leaf Light "China"
- Kvaser BlackBird SemiPro
- Kvaser USBcan R
Signed-off-by: Daniel Berglund <db@kvaser.com>
Signed-off-by: Olivier Sobrie <olivier@sobrie.be>
Signed-off-by: Marc Kleine-Budde <mkl@pengutronix.de>