Add Clock Domain support to the R-Car H1 Clock Pulse Generator (CPG)
driver using the generic PM Domain. This allows to power-manage the
module clocks of SoC devices that are part of the CPG/MSTP Clock Domain
using Runtime PM, or for system suspend/resume.
SoC devices that are part of the CPG/MSTP Clock Domain and can be
power-managed through an MSTP clock should be tagged in DT with a proper
"power-domains" property.
Also update the reg property in the DT binding doc example to match the
actual dtsi, which uses #address-cells and #size-cells == 1, not 2.
Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Acked-by: Stephen Boyd <sboyd@codeaurora.org>
Reviewed-by: Ulf Hansson <ulf.hansson@linaro.org>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
The R8A7779 SoC has several clocks that are too custom to be supported in a
generic driver. Those clocks are all fixed rate clocks with multiplier and
divisor set according to boot mode configuration.
Based on work for R-Car Gen2 SoCs by Laurent Pinchart.
Cc: devicetree@vger.kernel.org
Acked-by: Laurent Pinchart <laurent.pinchart@ideasonboard.com>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
Signed-off-by: Mike Turquette <mturquette@linaro.org>