Commit Graph

2225 Commits

Author SHA1 Message Date
Chaitanya Kulkarni
20c2c3bb83 nvmet: add nvmet_req_subsys() helper
Just like what we have to get the passthru ctrl from the req, add an
helper to get the subsystem associated with the nvmet_req() instead
of open coding the chain of structures.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:05 +01:00
Chaitanya Kulkarni
d86481e924 nvmet: use min of device_path and disk len
In function __assign_req_name() instead of using the DEVICE_NAME_LEN in
strncpy() use min of DISK_NAME_LEN and strlen(req->ns->device_path).

This is needed to turn off the following warnings:-

In file included from drivers/nvme/target/core.c:14:
In function ‘__assign_req_name’,
    inlined from ‘trace_event_raw_event_nvmet_req_init’ at drivers/nvme/target/./trace.h:58:1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
   strncpy(name, req->ns->device_path, DISK_NAME_LEN);
   ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
    inlined from ‘perf_trace_nvmet_req_complete’ at drivers/nvme/target/./trace.h💯1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
   strncpy(name, req->ns->device_path, DISK_NAME_LEN);
   ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
    inlined from ‘perf_trace_nvmet_req_init’ at drivers/nvme/target/./trace.h:58:1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
   strncpy(name, req->ns->device_path, DISK_NAME_LEN);
   ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
In function ‘__assign_req_name’,
    inlined from ‘trace_event_raw_event_nvmet_req_complete’ at drivers/nvme/target/./trace.h💯1:
drivers/nvme/target/trace.h:52:3: warning: ‘strncpy’ specified bound 32 equals destination size [-Wstringop-truncation]
   strncpy(name, req->ns->device_path, DISK_NAME_LEN);
   ^~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:05 +01:00
Chaitanya Kulkarni
07116ea50f nvmet: use invalid cmd opcode helper
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.

Use the previously introduced helper in the passthru backend to make the
error message uniform.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:05 +01:00
Chaitanya Kulkarni
1c2c761368 nvmet: use invalid cmd opcode helper
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.

Use the previously introduced helper in file backend to reduce the
duplicate code and make the error message uniform.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:05 +01:00
Chaitanya Kulkarni
d81d57cf1b nvmet: add helper to report invalid opcode
In the NVMeOF block device backend, file backend, and passthru backend
we reject and report the commands if opcode is not handled.

Add an helper and use it in block device backend to keep the code
and error message uniform.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:05 +01:00
Chaitanya Kulkarni
3999434b6c nvmet: remove extra variable in id-ns handler
In nvmet_execute_identify_ns() local variable ctrl is accessed only in
one place, remove that and directly use it from nvmet_req->sq->ctrl.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:04 +01:00
Chaitanya Kulkarni
3a1f7c79ae nvmet: make nvmet_find_namespace() req based
The six callers of nvmet_find_namespace() duplicate the error log page
update and status setting code for each call on failure.

All callers are nvmet requests based functions, so we can pass req
to the nvmet_find_namesapce() & derive ctrl from req, that'll allow us
to update the error log page in nvmet_find_namespace(). Now that we
pass the request we can also get rid of the local variable in
nvmet_find_namespace() and use the req->ns and return the error code.

Replace the ctrl parameter with nvmet_req for nvmet_find_namespace(),
centralize the error log page update for non allocated namesapces, and
return uniform error for non-allocated namespace.

The nvmet_find_namespace() takes nsid parameter which is from NVMe
commands structures such as get_log_page, identify, rw and common. All
these commands have same offset for the nsid field.

Derive nsid from req->cmd->common.nsid) & remove the extra parameter
from the nvmet_find_namespace().

Lastly now we associate the ns to the req parameter that we pass to the
nvmet_find_namespace(), rename nvmet_find_namespace() to
nvmet_req_find_ns().

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:04 +01:00
Chaitanya Kulkarni
aa0aff604a nvmet: return uniform error for invalid ns
For nvmet_find_namespace() error case we have inconsistent error code
mapping in the function nvmet_get_smart_log_nsid() and
nvmet_set_feat_write_protect().

There is no point in retrying for the invalid namesapce from the host
side. Set the error code to the NVME_SC_INVALID_NS | NVME_SC_DNR which
matches what we have in nvmet_execute_identify_desclist().

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:04 +01:00
Chaitanya Kulkarni
40244ad36b nvmet: set status to 0 in case for invalid nsid
For unallocated namespace in nvmet_execute_identify_ns() don't set the
status to NVME_SC_INVALID_NS, set it to zero.

Fixes: bffcd50778 ("nvmet: set right status on error in id-ns handler")
Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:04 +01:00
Christoph Hellwig
b5df8e79a2 nvmet-fc: add a missing __rcu annotation to nvmet_fc_tgt_assoc.queues
Make sparse happy after the recent conversion to RCU lookups.

Fixes: 4e2f02bf77 ("nvmet-fc: use RCU proctection for assoc_list")
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
2021-02-10 16:38:04 +01:00
Keith Busch
73a1a2298f nvme-multipath: set nr_zones for zoned namespaces
The bio based drivers only require the request_queue's nr_zones is set,
so set this field in the head if the namespace path is zoned.

Fixes: 240e6ee272 ("nvme: support for zoned namespaces")
Reported-by: Minwoo Im <minwoo.im.dev@gmail.com>
Cc: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Keith Busch <kbusch@kernel.org>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:04 +01:00
Sagi Grimberg
0fbcfb089a nvmet-tcp: fix potential race of tcp socket closing accept_work
When we accept a TCP connection and allocate an nvmet-tcp queue we should
make sure not to fully establish it or reference it as the connection may
be already closing, which triggers queue release work, which does not
fence against queue establishment.

In order to address such a race, we make sure to check the sk_state and
contain the queue reference to be done underneath the sk_callback_lock
such that the queue release work correctly fences against it.

Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Elad Grupi <elad.grupi@dell.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:03 +01:00
Sagi Grimberg
fda871c0ba nvmet-tcp: fix receive data digest calculation for multiple h2cdata PDUs
When a host sends multiple h2cdata PDUs for a single command, we
should verify the data digest calculation per PDU and not
per command.

Fixes: 872d26a391 ("nvmet-tcp: add NVMe over TCP target driver")
Reported-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Tested-by: Narayan Ayalasomayajula <Narayan.Ayalasomayajula@wdc.com>
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:03 +01:00
Chao Leng
62eca39722 nvme-rdma: handle nvme_rdma_post_send failures better
nvme_rdma_post_send failing is a path related error and should bounce
to another path when using nvme-multipath.  Call nvme_host_path_error
when nvme_rdma_post_send returns -EIO to ensure nvme_complete_rq gets
invoked to fail over to another path if there is one.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:03 +01:00
Chao Leng
ea5e5f42cd nvme-fabrics: avoid double completions in nvmf_fail_nonready_command
When reconnecting, the request may be completed with
NVME_SC_HOST_PATH_ERROR in nvmf_fail_nonready_command, which currently
set the state of the request to MQ_RQ_IN_FLIGHT before calling
nvme_complete_rq.  When this happens for a request that is freed by
the caller, such as nvme_submit_user_cmd, in the worst case the request
could be completed again in tear down process.

Instead of calling blk_mq_start_request from nvmf_fail_nonready_command,
just use the new nvme_host_path_error helper to complete the command
without starting it.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:03 +01:00
Chao Leng
dda3248e7f nvme: introduce a nvme_host_path_error helper
When using nvme native multipathing, if a path related error occurs
during ->queue_rq, the request needs to be completed with
NVME_SC_HOST_PATH_ERROR so that the request can be failed over.

Introduce a helper to complete the command from ->queue_rq in a wait
that invokes nvme_complete_rq.

Signed-off-by: Chao Leng <lengchao@huawei.com>
[hch: renamed, added a return value to clean up the callers a bit]
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:03 +01:00
Jiapeng Chong
f720a8edbc nvme: convert sysfs sprintf/snprintf family to sysfs_emit
Fix the following coccicheck warning:

./drivers/nvme/host/core.c:3580:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3570:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3560:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:3526:8-16: WARNING: use scnprintf or sprintf.
./drivers/nvme/host/core.c:2833:8-16: WARNING: use scnprintf or sprintf.

Reported-by: Abaci Robot<abaci@linux.alibaba.com>
Signed-off-by: Jiapeng Chong <jiapeng.chong@linux.alibaba.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Reviewed-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-10 16:38:02 +01:00
Chao Leng
563c81586d nvme-tcp: use cancel tagset helper for tear down
Use nvme_cancel_tagset and nvme_cancel_admin_tagset to clean code for
tear down process.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:13 +01:00
Chao Leng
c4189d680e nvme-rdma: use cancel tagset helper for tear down
Use nvme_cancel_tagset and nvme_cancel_admin_tagset to clean code for
tear down process.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:12 +01:00
Chao Leng
70a99574a7 nvme-tcp: add clean action for failed reconnection
If reconnect failed after start io queues, the queues will be unquiesced
and new requests continue to be delivered. Reconnection error handling
process directly free queues without cancel suspend requests. The
suppend request will time out, and then crash due to use the queue
after free.

Add sync queues and cancel suppend requests for reconnection error
handling.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:12 +01:00
Chao Leng
958dc1d32c nvme-rdma: add clean action for failed reconnection
A crash happens when inject failed reconnection.
If reconnect failed after start io queues, the queues will be unquiesced
and new requests continue to be delivered. Reconnection error handling
process directly free queues without cancel suspend requests. The
suppend request will time out, and then crash due to use the queue
after free.

Add sync queues and cancel suppend requests for reconnection error
handling.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:12 +01:00
Chao Leng
2547906982 nvme-core: add cancel tagset helpers
Add nvme_cancel_tagset and nvme_cancel_admin_tagset for tear down and
reconnection error handling.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:12 +01:00
Chaitanya Kulkarni
8f8ea928fd nvme-core: get rid of the extra space
Remove the extra space in the nvme_free_cels() when calling
xa_for_each loop which is not a common practice
(except drivers/infiniband/core/ not sure why).

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:12 +01:00
Johannes Thumshirn
4a407d5ebc nvme: add tracing of zns commands
When support for the NVMe ZNS commands was merged, tracing of these has
been omitted.

Add nvme_cmd_zone_mgmt_send, nvme_cmd_zone_mgmt_recv as well as
nvme_cmd_zone_append to the nvme driver's tracing facility.

Signed-off-by: Johannes Thumshirn <johannes.thumshirn@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:12 +01:00
Michal Krakowiak
3a98c51a24 nvme: parse format nvm command details when tracing
Add detailed parsing of format nvm admin command to make the
trace log more consistent and human-readable.

Signed-off-by: Michal Krakowiak <michal.krakowiak@intel.com>
Acked-by: Dan Williams <dan.j.williams@intel.com>
Reviewed-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:12 +01:00
Chaitanya Kulkarni
193fcf371f nvmet: add lba to sect conversion helpers
In this preparation patch, we add helpers to convert lbas to sectors &
sectors to lba. This is needed to eliminate code duplication in the ZBD
backend.

Use these helpers in the block device backend.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Damien Le Moal <damien.lemoal@wdc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Chaitanya Kulkarni
3c7b224f19 nvmet: remove extra variable in identify ns
We remove the extra local variable struct nvmet_ns in
nvmet_execute_identify_ns() since req already has ns member that can be
reused, this also eliminates the explicit call to nvmet_put_namespace()
which is already present in the request completion path.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Chaitanya Kulkarni
3631c7f4a2 nvmet: remove extra variable in id-desclist
We remove the extra local variable struct nvmet_ns in
nvmet_execute_identify_desclist() since req already has ns member that
can be reused, this also eliminates the explicit call to
nvmet_put_namespace() which is already present in the request
completion path.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Chaitanya Kulkarni
624e67fdf9 nvmet: remove extra variable in smart log nsid
We remove the extra local variable struct nvmet_ns in
nvmet_get_smart_log_nsid() since req already has ns member that can be
reused, this also eliminates the explicit call to nvmet_put_namespace()
which is already present in the request completion path.

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Minwoo Im
fc97e942d9 nvme: refactor ns->ctrl by request
Just for current code in nvme_cleanup_cmd(), we don't have to get
namespace instance, but we need controller instance.

Controller instance can be retrieved by namespace instance, but it can
be directly accessed by nvme_request instance from request.

	ctrl = nvme_req(req)->ctrl;

We don't have to go around namespace instance from request instance
through gendisk.

Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Sagi Grimberg
0dc9edaf80 nvme-tcp: pass multipage bvec to request iov_iter
iov_iter uses the right helpers so we should be able
to pass in a multipage bvec. Right now the iov_iter is
initialized with more segments that it needs which doesn't
fail because the iov_iter is capped by byte count, but it
is better to use a full multipage bvec iter.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Sagi Grimberg
60141aa08c nvme-tcp: get rid of unused helper function
Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Sagi Grimberg
cb9b870fba nvme-tcp: fix wrong setting of request iov_iter
We might set the iov_iter direction wrong, which is harmless for this
use-case, but get it right. Also this makes the code slightly cleaner.

Signed-off-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:11 +01:00
Minwoo Im
f9063a5327 nvme: support command retry delay for admin command
The controller can request a delay retrying a failed command by setting
the Command Retry Delay (CRD) field in the Completion Queue Entry.

Currentlty this features is only applied to commands on the I/O queue, but
not to commands on the admin queue.  Retreive the nvme_ctrl from the
request so that no namespace is required and apply the feature to all
commands.

Signed-off-by: Minwoo Im <minwoo.im.dev@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:10 +01:00
Rikard Falkeborn
60b152a508 nvme: constify static attribute_group structs
The only usage of these is to put their addresses in arrays of pointers
to const attribute_groups. Make them const to allow the compiler to put
them in read-only memory.

Signed-off-by: Rikard Falkeborn <rikard.falkeborn@gmail.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:10 +01:00
Leonid Ravich
4e2f02bf77 nvmet-fc: use RCU proctection for assoc_list
searching assoc_list protected by rcu_read_lock if list not changed inline.
and according to the rcu list rules.

queue array embedded into nvmet_fc_tgt_assoc protected by rcu_read_lock
according to rcu dereference/assign rules.

queue and assoc object freed after grace period by call_rcu.

tgtport lock taken for changing assoc_list.

Reviewed-by: Eldad Zinger <Eldad.Zinger@dell.com>
Reviewed-by: Elad Grupi <Elad.Grupi@dell.com>
Reviewed-by: James Smart <james.smart@broadcom.com>
Signed-off-by: Leonid Ravich <Leonid.Ravich@emc.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:10 +01:00
Israel Rukshin
36ca03c830 nvmet: Fix nvmet_is_port_enabled indentation
Remove extra tab.

Signed-off-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:10 +01:00
Israel Rukshin
cc34562261 nvmet: Use nvmet_is_port_enabled helper for pi_enable
Remove code duplication.

Signed-off-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Max Gurtovoy <mgurtovoy@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-02-02 10:26:10 +01:00
Christoph Hellwig
a7c7f7b2b6 nvme: use bio_set_dev to assign ->bi_bdev
Always use the bio_set_dev helper to assign ->bi_bdev to make sure
other state related to the device is uptodate.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2021-01-26 08:50:01 -07:00
Guoqing Jiang
684da7628d block: remove unnecessary argument from blk_execute_rq
We can remove 'q' from blk_execute_rq as well after the previous change
in blk_execute_rq_nowait.

And more importantly it never really was needed to start with given
that we can trivial derive it from struct request.

Cc: linux-scsi@vger.kernel.org
Cc: virtualization@lists.linux-foundation.org
Cc: linux-ide@vger.kernel.org
Cc: linux-mmc@vger.kernel.org
Cc: linux-nvme@lists.infradead.org
Cc: linux-nfs@vger.kernel.org
Acked-by: Ulf Hansson <ulf.hansson@linaro.org> # for mmc
Signed-off-by: Guoqing Jiang <guoqing.jiang@cloud.ionos.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2021-01-24 21:52:39 -07:00
Guoqing Jiang
8eeed0b554 block: remove unnecessary argument from blk_execute_rq_nowait
The 'q' is not used since commit a1ce35fa49 ("block: remove dead
elevator code"), also update the comment of the function.

And more importantly it never really was needed to start with given
that we can trivial derive it from struct request.

Cc: target-devel@vger.kernel.org
Cc: linux-scsi@vger.kernel.org
Cc: virtualization@lists.linux-foundation.org
Cc: linux-ide@vger.kernel.org
Cc: linux-mmc@vger.kernel.org
Cc: linux-nvme@lists.infradead.org
Cc: linux-nfs@vger.kernel.org
Signed-off-by: Guoqing Jiang <guoqing.jiang@cloud.ionos.com>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2021-01-24 21:52:39 -07:00
Christoph Hellwig
309dca309f block: store a block_device pointer in struct bio
Replace the gendisk pointer in struct bio with a pointer to the newly
improved struct block device.  From that the gendisk can be trivially
accessed with an extra indirection, but it also allows to directly
look up all information related to partition remapping.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Acked-by: Tejun Heo <tj@kernel.org>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2021-01-24 18:17:20 -07:00
Christoph Hellwig
d11cd28998 nvme: allow revalidate to set a namespace read-only
Unconditionally call set_disk_ro now that it only updates the hardware
state.  This allows to properly set up the Linux devices read-only when
the controller turns a previously writable namespace read-only.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Martin K. Petersen <martin.petersen@oracle.com>
Reviewed-by: Hannes Reinecke <hare@suse.de>
Signed-off-by: Jens Axboe <axboe@kernel.dk>
2021-01-24 18:15:57 -07:00
Christoph Hellwig
fa0732168f nvme-pci: fix error unwind in nvme_map_data
Properly unwind step by step using refactored helpers from nvme_unmap_data
to avoid a potential double dma_unmap on a mapping failure.

Fixes: 7fe07d14f7 ("nvme-pci: merge nvme_free_iod into nvme_unmap_data")
Reported-by: Marc Orr <marcorr@google.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Marc Orr <marcorr@google.com>
2021-01-20 18:56:33 +01:00
Christoph Hellwig
9275c206f8 nvme-pci: refactor nvme_unmap_data
Split out three helpers from nvme_unmap_data that will allow finer grained
unwinding from nvme_map_data.

Signed-off-by: Christoph Hellwig <hch@lst.de>
Reviewed-by: Keith Busch <kbusch@kernel.org>
Reviewed-by: Marc Orr <marcorr@google.com>
2021-01-20 18:56:26 +01:00
Chaitanya Kulkarni
bffcd50778 nvmet: set right status on error in id-ns handler
The function nvmet_execute_identify_ns() doesn't set the status if call
to nvmet_find_namespace() fails. In that case we set the status of the
request to the value return by the nvmet_copy_sgl().

Set the status to NVME_SC_INVALID_NS and adjust the code such that
request will have the right status on nvmet_find_namespace() failure.

Without this patch :-
NVME Identify Namespace 3:
nsze    : 0
ncap    : 0
nuse    : 0
nsfeat  : 0
nlbaf   : 0
flbas   : 0
mc      : 0
dpc     : 0
dps     : 0
nmic    : 0
rescap  : 0
fpi     : 0
dlfeat  : 0
nawun   : 0
nawupf  : 0
nacwu   : 0
nabsn   : 0
nabo    : 0
nabspf  : 0
noiob   : 0
nvmcap  : 0
mssrl   : 0
mcl     : 0
msrc    : 0
nsattr	: 0
nvmsetid: 0
anagrpid: 0
endgid  : 0
nguid   : 00000000000000000000000000000000
eui64   : 0000000000000000
lbaf  0 : ms:0   lbads:0  rp:0 (in use)

With this patch-series :-
feb3b88b501e (HEAD -> nvme-5.11) nvmet: remove extra variable in identify ns
6302aa67210a nvmet: remove extra variable in id-desclist
ed57951da453 nvmet: remove extra variable in smart log nsid
be384b8c24dc nvmet: set right status on error in id-ns handler

NVMe status: INVALID_NS: The namespace or the format of that namespace is invalid(0xb)

Signed-off-by: Chaitanya Kulkarni <chaitanya.kulkarni@wdc.com>
Reviewed-by: Sagi Grimberg <sagi@grimberg.me>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-01-18 18:58:19 +01:00
Klaus Jensen
20d3bb92e8 nvme-pci: allow use of cmb on v1.4 controllers
Since NVMe v1.4 the Controller Memory Buffer must be explicitly enabled
by the host.

Signed-off-by: Klaus Jensen <k.jensen@samsung.com>
[hch: avoid a local variable and add a comment]
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-01-18 18:58:18 +01:00
Chao Leng
9ebbfe495e nvme-tcp: avoid request double completion for concurrent nvme_tcp_timeout
Each name space has a request queue, if complete request long time,
multi request queues may have time out requests at the same time,
nvme_tcp_timeout will execute concurrently. Multi requests in different
request queues may be queued in the same tcp queue, multi
nvme_tcp_timeout may call nvme_tcp_stop_queue at the same time.
The first nvme_tcp_stop_queue will clear NVME_TCP_Q_LIVE and continue
stopping the tcp queue(cancel io_work), but the others check
NVME_TCP_Q_LIVE is already cleared, and then directly complete the
requests, complete request before the io work is completely canceled may
lead to a use-after-free condition.
Add a multex lock to serialize nvme_tcp_stop_queue.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-01-18 18:58:18 +01:00
Chao Leng
7674073b2e nvme-rdma: avoid request double completion for concurrent nvme_rdma_timeout
A crash happens when inject completing request long time(nearly 30s).
Each name space has a request queue, when inject completing request long
time, multi request queues may have time out requests at the same time,
nvme_rdma_timeout will execute concurrently. Multi requests in different
request queues may be queued in the same rdma queue, multi
nvme_rdma_timeout may call nvme_rdma_stop_queue at the same time.
The first nvme_rdma_timeout will clear NVME_RDMA_Q_LIVE and continue
stopping the rdma queue(drain qp), but the others check NVME_RDMA_Q_LIVE
is already cleared, and then directly complete the requests, complete
request before the qp is fully drained may lead to a use-after-free
condition.

Add a multex lock to serialize nvme_rdma_stop_queue.

Signed-off-by: Chao Leng <lengchao@huawei.com>
Tested-by: Israel Rukshin <israelr@nvidia.com>
Reviewed-by: Israel Rukshin <israelr@nvidia.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-01-18 18:58:18 +01:00
Revanth Rajashekar
4d6b1c95b9 nvme: check the PRINFO bit before deciding the host buffer length
According to NVMe spec v1.4, section 8.3.1, the PRINFO bit and
the metadata size play a vital role in deteriming the host buffer size.

If PRIFNO bit is set and MS==8, the host doesn't add the metadata buffer,
instead the controller adds it.

Signed-off-by: Revanth Rajashekar <revanth.rajashekar@intel.com>
Signed-off-by: Christoph Hellwig <hch@lst.de>
2021-01-18 18:58:16 +01:00