From fca83058753456528bef62579ae2b50799d7a473 Mon Sep 17 00:00:00 2001 From: Niklas Cassel Date: Wed, 28 Mar 2018 13:50:13 +0200 Subject: [PATCH] PCI: endpoint: Handle 64-bit BARs properly If a 64-bit BAR was set-up, we need to skip a BAR, since a 64-bit BAR consists of a BAR pair. We need to check what BAR width the epc->ops->set_bar() specific implementation actually did set-up, since some drivers, like the Cadence EP controller, sometimes sets up a 64-bit BAR, even though a 32-bit BAR was requested. Signed-off-by: Niklas Cassel Signed-off-by: Lorenzo Pieralisi Acked-by: Kishon Vijay Abraham I --- drivers/pci/endpoint/functions/pci-epf-test.c | 7 +++++++ 1 file changed, 7 insertions(+) diff --git a/drivers/pci/endpoint/functions/pci-epf-test.c b/drivers/pci/endpoint/functions/pci-epf-test.c index 91274779e59f..d46e3ebabb8e 100644 --- a/drivers/pci/endpoint/functions/pci-epf-test.c +++ b/drivers/pci/endpoint/functions/pci-epf-test.c @@ -380,6 +380,13 @@ static int pci_epf_test_set_bar(struct pci_epf *epf) if (bar == test_reg_bar) return ret; } + /* + * pci_epc_set_bar() sets PCI_BASE_ADDRESS_MEM_TYPE_64 + * if the specific implementation required a 64-bit BAR, + * even if we only requested a 32-bit BAR. + */ + if (epf_bar->flags & PCI_BASE_ADDRESS_MEM_TYPE_64) + bar++; } return 0;