staging/xgifb: Consolidate if branches with similar conditions
1) The same condition (pVBInfo->IF_DEF_LVDS == 0) was checked in the if clause directly in front of this one. 2) The same condition pVBInfo->VBType & (VB_SIS301B | VB_SIS302B | VB_SIS301LV | VB_SIS302LV | VB_XGI301C) was checked in the if clause directly in front of this one. Signed-off-by: Peter Huewe <peterhuewe@gmx.de> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
826215d98f
commit
f951dd05f9
@ -2299,9 +2299,7 @@ static unsigned char XGI_GetLCDInfo(unsigned short ModeNo,
|
||||
& VB_XGI301C)) && (tempax & XGI_LCDDualLink)) {
|
||||
tempbx |= SetLCDDualLink;
|
||||
}
|
||||
}
|
||||
|
||||
if (pVBInfo->IF_DEF_LVDS == 0) {
|
||||
if ((pVBInfo->LCDResInfo == Panel_1400x1050) && (pVBInfo->VBInfo
|
||||
& SetCRT2ToLCD) && (resinfo == 9) &&
|
||||
(!(tempbx & EnableScalingLCD)))
|
||||
@ -5024,12 +5022,8 @@ static void XGI_SetLCDCap(struct vb_device_info *pVBInfo)
|
||||
|
||||
tempcx = pVBInfo->LCDCapList[XGI_GetLCDCapPtr(pVBInfo)].LCD_Capability;
|
||||
|
||||
if (pVBInfo->VBType &
|
||||
(VB_SIS301B |
|
||||
VB_SIS302B |
|
||||
VB_SIS301LV |
|
||||
VB_SIS302LV |
|
||||
VB_XGI301C)) { /* 301LV/302LV only */
|
||||
if (pVBInfo->VBType & (VB_SIS301B | VB_SIS302B | VB_SIS301LV |
|
||||
VB_SIS302LV | VB_XGI301C)) {
|
||||
if (pVBInfo->VBType &
|
||||
(VB_SIS301LV | VB_SIS302LV | VB_XGI301C)) {
|
||||
/* Set 301LV Capability */
|
||||
@ -5041,10 +5035,7 @@ static void XGI_SetLCDCap(struct vb_device_info *pVBInfo)
|
||||
~((EnableVBCLKDRVLOW | EnablePLLSPLOW) >> 8),
|
||||
(unsigned short) ((tempcx & (EnableVBCLKDRVLOW
|
||||
| EnablePLLSPLOW)) >> 8));
|
||||
}
|
||||
|
||||
if (pVBInfo->VBType & (VB_SIS301B | VB_SIS302B | VB_SIS301LV
|
||||
| VB_SIS302LV | VB_XGI301C)) {
|
||||
if (pVBInfo->VBInfo & SetCRT2ToLCD)
|
||||
XGI_SetLCDCap_B(tempcx, pVBInfo);
|
||||
else if (pVBInfo->VBInfo & XGI_SetCRT2ToLCDA)
|
||||
|
Loading…