forked from Minki/linux
power: supply: bq27xxx: support missing supplier device
power_supply_am_i_supplied() can return negative error codes. In this case we should assume, that no charger is connected and the battery should be marked as DISCHARGING instead of NOT_CHARGING. Reported-by: Merlijn Wajer <merlijn@wizzup.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.co.uk>
This commit is contained in:
parent
66ec32fc7c
commit
f72c14ad8c
@ -1670,7 +1670,7 @@ static int bq27xxx_battery_status(struct bq27xxx_device_info *di,
|
||||
status = POWER_SUPPLY_STATUS_FULL;
|
||||
else if (di->cache.flags & BQ27000_FLAG_CHGS)
|
||||
status = POWER_SUPPLY_STATUS_CHARGING;
|
||||
else if (power_supply_am_i_supplied(di->bat))
|
||||
else if (power_supply_am_i_supplied(di->bat) > 0)
|
||||
status = POWER_SUPPLY_STATUS_NOT_CHARGING;
|
||||
else
|
||||
status = POWER_SUPPLY_STATUS_DISCHARGING;
|
||||
|
Loading…
Reference in New Issue
Block a user