powerpc/windfarm: Improve display of fan speeds in sysfs

Controls registered as RPM and PWM fans are now displayed
with the "RPM" or "%" suffix respectively to make it
clearer to the user what the value actually means since
the fan type isn't otherwise obvious.

Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
This commit is contained in:
Benjamin Herrenschmidt 2012-04-18 22:16:50 +00:00
parent a94d72b136
commit ea5c64b067

View File

@ -164,13 +164,24 @@ static ssize_t wf_show_control(struct device *dev,
struct device_attribute *attr, char *buf)
{
struct wf_control *ctrl = container_of(attr, struct wf_control, attr);
const char *typestr;
s32 val = 0;
int err;
err = ctrl->ops->get_value(ctrl, &val);
if (err < 0)
return err;
return sprintf(buf, "%d\n", val);
switch(ctrl->type) {
case WF_CONTROL_RPM_FAN:
typestr = " RPM";
break;
case WF_CONTROL_PWM_FAN:
typestr = " %";
break;
default:
typestr = "";
}
return sprintf(buf, "%d%s\n", val, typestr);
}
/* This is really only for debugging... */