power: supply: sc27xx: Add CURRENT_NOW/VOLTAGE_NOW properties support
Add new properties to get present current and voltage of the fuel gauge. Signed-off-by: Yuanjiang Yu <yuanjiang.yu@unisoc.com> Signed-off-by: Baolin Wang <baolin.wang7@gmail.com> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
8720b255f5
commit
e5431c3408
@ -42,6 +42,8 @@
|
||||
#define SC27XX_FGU_USER_AREA_SET 0xa0
|
||||
#define SC27XX_FGU_USER_AREA_CLEAR 0xa4
|
||||
#define SC27XX_FGU_USER_AREA_STATUS 0xa8
|
||||
#define SC27XX_FGU_VOLTAGE_BUF 0xd0
|
||||
#define SC27XX_FGU_CURRENT_BUF 0xf0
|
||||
|
||||
#define SC27XX_WRITE_SELCLB_EN BIT(0)
|
||||
#define SC27XX_FGU_CLBCNT_MASK GENMASK(15, 0)
|
||||
@ -376,6 +378,44 @@ static int sc27xx_fgu_get_clbcnt(struct sc27xx_fgu_data *data, int *clb_cnt)
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int sc27xx_fgu_get_vol_now(struct sc27xx_fgu_data *data, int *val)
|
||||
{
|
||||
int ret;
|
||||
u32 vol;
|
||||
|
||||
ret = regmap_read(data->regmap, data->base + SC27XX_FGU_VOLTAGE_BUF,
|
||||
&vol);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
/*
|
||||
* It is ADC values reading from registers which need to convert to
|
||||
* corresponding voltage values.
|
||||
*/
|
||||
*val = sc27xx_fgu_adc_to_voltage(data, vol);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int sc27xx_fgu_get_cur_now(struct sc27xx_fgu_data *data, int *val)
|
||||
{
|
||||
int ret;
|
||||
u32 cur;
|
||||
|
||||
ret = regmap_read(data->regmap, data->base + SC27XX_FGU_CURRENT_BUF,
|
||||
&cur);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
||||
/*
|
||||
* It is ADC values reading from registers which need to convert to
|
||||
* corresponding current values.
|
||||
*/
|
||||
*val = sc27xx_fgu_adc_to_current(data, cur - SC27XX_FGU_CUR_BASIC_ADC);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int sc27xx_fgu_get_capacity(struct sc27xx_fgu_data *data, int *cap)
|
||||
{
|
||||
int ret, cur_clbcnt, delta_clbcnt, delta_cap, temp;
|
||||
@ -577,7 +617,7 @@ static int sc27xx_fgu_get_property(struct power_supply *psy,
|
||||
val->intval = value;
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_AVG:
|
||||
ret = sc27xx_fgu_get_vbat_vol(data, &value);
|
||||
if (ret)
|
||||
goto error;
|
||||
@ -601,7 +641,6 @@ static int sc27xx_fgu_get_property(struct power_supply *psy,
|
||||
val->intval = value;
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_CURRENT_NOW:
|
||||
case POWER_SUPPLY_PROP_CURRENT_AVG:
|
||||
ret = sc27xx_fgu_get_current(data, &value);
|
||||
if (ret)
|
||||
@ -625,6 +664,22 @@ static int sc27xx_fgu_get_property(struct power_supply *psy,
|
||||
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_VOLTAGE_NOW:
|
||||
ret = sc27xx_fgu_get_vol_now(data, &value);
|
||||
if (ret)
|
||||
goto error;
|
||||
|
||||
val->intval = value * 1000;
|
||||
break;
|
||||
|
||||
case POWER_SUPPLY_PROP_CURRENT_NOW:
|
||||
ret = sc27xx_fgu_get_cur_now(data, &value);
|
||||
if (ret)
|
||||
goto error;
|
||||
|
||||
val->intval = value * 1000;
|
||||
break;
|
||||
|
||||
default:
|
||||
ret = -EINVAL;
|
||||
break;
|
||||
@ -694,6 +749,7 @@ static enum power_supply_property sc27xx_fgu_props[] = {
|
||||
POWER_SUPPLY_PROP_CAPACITY,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_NOW,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_OCV,
|
||||
POWER_SUPPLY_PROP_VOLTAGE_AVG,
|
||||
POWER_SUPPLY_PROP_CURRENT_NOW,
|
||||
POWER_SUPPLY_PROP_CURRENT_AVG,
|
||||
POWER_SUPPLY_PROP_CONSTANT_CHARGE_VOLTAGE,
|
||||
|