iio: magnetometer: rm3100: Use get_unaligned_be24()
This makes the driver code slightly easier to read. Cc: Song Qiang <songqiang1304521@gmail.com> Signed-off-by: Andy Shevchenko <andriy.shevchenko@linux.intel.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
d2fa63d2d1
commit
dfe3da0b28
@ -22,6 +22,8 @@
|
||||
#include <linux/iio/triggered_buffer.h>
|
||||
#include <linux/iio/trigger_consumer.h>
|
||||
|
||||
#include <asm/unaligned.h>
|
||||
|
||||
#include "rm3100.h"
|
||||
|
||||
/* Cycle Count Registers. */
|
||||
@ -223,8 +225,7 @@ static int rm3100_read_mag(struct rm3100_data *data, int idx, int *val)
|
||||
goto unlock_return;
|
||||
mutex_unlock(&data->lock);
|
||||
|
||||
*val = sign_extend32((buffer[0] << 16) | (buffer[1] << 8) | buffer[2],
|
||||
23);
|
||||
*val = sign_extend32(get_unaligned_be24(&buffer[0]), 23);
|
||||
|
||||
return IIO_VAL_INT;
|
||||
|
||||
|