drm/bridge: anx7625: Fix overflow issue on reading EDID
The length of EDID block can be longer than 256 bytes, so we should use
`int` instead of `u8` for the `edid_pos` variable.
Fixes: 8bdfc5dae4
("drm/bridge: anx7625: Add anx7625 MIPI DSI/DPI to DP")
Signed-off-by: Pin-Yen Lin <treapking@chromium.org>
Reviewed-by: Jernej Skrabec <jernej.skrabec@gmail.com>
Signed-off-by: Robert Foss <robert.foss@linaro.org>
Link: https://patchwork.freedesktop.org/patch/msgid/20220210103827.402436-1-treapking@chromium.org
This commit is contained in:
parent
7db47b8388
commit
d5c6f647ae
@ -1109,7 +1109,8 @@ static int segments_edid_read(struct anx7625_data *ctx,
|
||||
static int sp_tx_edid_read(struct anx7625_data *ctx,
|
||||
u8 *pedid_blocks_buf)
|
||||
{
|
||||
u8 offset, edid_pos;
|
||||
u8 offset;
|
||||
int edid_pos;
|
||||
int count, blocks_num;
|
||||
u8 pblock_buf[MAX_DPCD_BUFFER_SIZE];
|
||||