[S390] cio: Allow 0 and 1 as input for channel path status attribute.
Channel path status can now be modified by writing '0' and '1' to the sysfs status attribute in addition to 'offline' and 'online' respectively. Signed-off-by: Peter Oberparleiter <peter.oberparleiter@de.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com> Signed-off-by: Heiko Carstens <heiko.carstens@de.ibm.com>
This commit is contained in:
parent
f86635fad1
commit
d120b2a4e6
@ -1169,9 +1169,9 @@ chp_status_write(struct device *dev, struct device_attribute *attr, const char *
|
||||
if (!num_args)
|
||||
return count;
|
||||
|
||||
if (!strnicmp(cmd, "on", 2))
|
||||
if (!strnicmp(cmd, "on", 2) || !strcmp(cmd, "1"))
|
||||
error = s390_vary_chpid(cp->chpid, 1);
|
||||
else if (!strnicmp(cmd, "off", 3))
|
||||
else if (!strnicmp(cmd, "off", 3) || !strcmp(cmd, "0"))
|
||||
error = s390_vary_chpid(cp->chpid, 0);
|
||||
else
|
||||
error = -EINVAL;
|
||||
|
Loading…