DMA: fix printk warning in AMBA PL08x DMA driver

In Rob's recent pull request the patch
	ARM: highbank: select ARCH_DMA_ADDR_T_64BIT for LPAE
promotes dma_addr_t to 64bit, so printk generates a warning about
an incorrect type. Fix this by casting it to u64 and using %llx.
Fixing long lines on the way.

Signed-off-by: Andre Przywara <andre.przywara@linaro.org>
Signed-off-by: Rob Herring <rob.herring@calxeda.com>
This commit is contained in:
Andre Przywara 2013-08-14 14:52:09 +02:00 committed by Rob Herring
parent 1c38b28980
commit b90ca0636c

View File

@ -847,10 +847,13 @@ static int pl08x_fill_llis_for_desc(struct pl08x_driver_data *pl08x,
pl08x_choose_master_bus(&bd, &mbus, &sbus, cctl);
dev_vdbg(&pl08x->adev->dev, "src=0x%08x%s/%u dst=0x%08x%s/%u len=%zu\n",
bd.srcbus.addr, cctl & PL080_CONTROL_SRC_INCR ? "+" : "",
dev_vdbg(&pl08x->adev->dev,
"src=0x%08llx%s/%u dst=0x%08llx%s/%u len=%zu\n",
(u64)bd.srcbus.addr,
cctl & PL080_CONTROL_SRC_INCR ? "+" : "",
bd.srcbus.buswidth,
bd.dstbus.addr, cctl & PL080_CONTROL_DST_INCR ? "+" : "",
(u64)bd.dstbus.addr,
cctl & PL080_CONTROL_DST_INCR ? "+" : "",
bd.dstbus.buswidth,
bd.remainder);
dev_vdbg(&pl08x->adev->dev, "mbus=%s sbus=%s\n",