ARM: dts: rockchip: Fix vcc5/6-supply representation on rv1108-elgin
On rv1108-elgin-r1 board the RK805 VCC5 and VCC6 supplies come from the BUCK2 regulator at 2.2V, so fix the representation in the device tree. While at it, rename it from vdd_cam to vdd_buck2, which is a better name for the regulator label. Signed-off-by: Otavio Salvador <otavio@ossystems.com.br> Signed-off-by: Heiko Stuebner <heiko@sntech.de>
This commit is contained in:
parent
e6b97a47b5
commit
b86e2f2441
@ -74,8 +74,8 @@
|
||||
vcc2-supply = <&vcc_sys>;
|
||||
vcc3-supply = <&vcc_sys>;
|
||||
vcc4-supply = <&vcc_sys>;
|
||||
vcc5-supply = <&vcc_sys>;
|
||||
vcc6-supply = <&vcc_sys>;
|
||||
vcc5-supply = <&vdd_buck2>;
|
||||
vcc6-supply = <&vdd_buck2>;
|
||||
|
||||
regulators {
|
||||
vdd_core: DCDC_REG1 {
|
||||
@ -90,10 +90,12 @@
|
||||
};
|
||||
};
|
||||
|
||||
vdd_cam: DCDC_REG2 {
|
||||
regulator-name= "vdd_cam";
|
||||
regulator-min-microvolt = <700000>;
|
||||
regulator-max-microvolt = <2000000>;
|
||||
vdd_buck2: DCDC_REG2 {
|
||||
regulator-name= "vdd_buck2";
|
||||
regulator-min-microvolt = <2200000>;
|
||||
regulator-max-microvolt = <2200000>;
|
||||
regulator-always-on;
|
||||
regulator-boot-on;
|
||||
regulator-state-mem {
|
||||
regulator-state-disabled;
|
||||
};
|
||||
|
Loading…