forked from Minki/linux
platform/chrome: cros_ec_proto: Rename cros_ec_command function
cros_ec_command() is the name of a function as well as a struct, as such it can confuse indexing tools (like ctags). Avoid this by renaming it to cros_ec_cmd(). Update all the callsites to use the new name. This patch is a find-and-replace, so should not introduce any functional changes. Suggested-by: Stephen Boyd <swboyd@chromium.org> Signed-off-by: Prashant Malani <pmalani@chromium.org> Acked-by: Lee Jones <lee.jones@linaro.org> Reviewed-by: Stephen Boyd <swboyd@chromium.org> Reviewed-by: Guenter Roeck <groeck@chromium.org> Signed-off-by: Tzung-Bi Shih <tzungbi@kernel.org> Link: https://lore.kernel.org/r/20220606201825.763788-3-pmalani@chromium.org
This commit is contained in:
parent
015cd00435
commit
b1d288d9c3
@ -250,7 +250,7 @@ static int ec_device_probe(struct platform_device *pdev)
|
||||
* The PCHG device cannot be detected by sending EC_FEATURE_GET_CMD, but
|
||||
* it can be detected by querying the number of peripheral chargers.
|
||||
*/
|
||||
retval = cros_ec_command(ec->ec_dev, 0, EC_CMD_PCHG_COUNT, NULL, 0,
|
||||
retval = cros_ec_cmd(ec->ec_dev, 0, EC_CMD_PCHG_COUNT, NULL, 0,
|
||||
&pchg_count, sizeof(pchg_count));
|
||||
if (retval >= 0 && pchg_count.port_count) {
|
||||
retval = mfd_add_hotplug_devices(ec->dev,
|
||||
|
@ -860,7 +860,7 @@ bool cros_ec_check_features(struct cros_ec_dev *ec, int feature)
|
||||
|
||||
if (features->flags[0] == -1U && features->flags[1] == -1U) {
|
||||
/* features bitmap not read yet */
|
||||
ret = cros_ec_command(ec->ec_dev, 0, EC_CMD_GET_FEATURES + ec->cmd_offset,
|
||||
ret = cros_ec_cmd(ec->ec_dev, 0, EC_CMD_GET_FEATURES + ec->cmd_offset,
|
||||
NULL, 0, features, sizeof(*features));
|
||||
if (ret < 0) {
|
||||
dev_warn(ec->dev, "cannot get EC features: %d\n", ret);
|
||||
@ -942,7 +942,7 @@ int cros_ec_get_sensor_count(struct cros_ec_dev *ec)
|
||||
EXPORT_SYMBOL_GPL(cros_ec_get_sensor_count);
|
||||
|
||||
/**
|
||||
* cros_ec_command - Send a command to the EC.
|
||||
* cros_ec_cmd - Send a command to the EC.
|
||||
*
|
||||
* @ec_dev: EC device
|
||||
* @version: EC command version
|
||||
@ -954,7 +954,7 @@ EXPORT_SYMBOL_GPL(cros_ec_get_sensor_count);
|
||||
*
|
||||
* Return: >= 0 on success, negative error number on failure.
|
||||
*/
|
||||
int cros_ec_command(struct cros_ec_device *ec_dev,
|
||||
int cros_ec_cmd(struct cros_ec_device *ec_dev,
|
||||
unsigned int version,
|
||||
int command,
|
||||
void *outdata,
|
||||
@ -987,4 +987,4 @@ error:
|
||||
kfree(msg);
|
||||
return ret;
|
||||
}
|
||||
EXPORT_SYMBOL_GPL(cros_ec_command);
|
||||
EXPORT_SYMBOL_GPL(cros_ec_cmd);
|
||||
|
@ -525,7 +525,7 @@ static int cros_typec_configure_mux(struct cros_typec_data *typec, int port_num,
|
||||
enum typec_orientation orientation;
|
||||
int ret;
|
||||
|
||||
ret = cros_ec_command(typec->ec, 0, EC_CMD_USB_PD_MUX_INFO,
|
||||
ret = cros_ec_cmd(typec->ec, 0, EC_CMD_USB_PD_MUX_INFO,
|
||||
&req, sizeof(req), &resp, sizeof(resp));
|
||||
if (ret < 0) {
|
||||
dev_warn(typec->dev, "Failed to get mux info for port: %d, err = %d\n",
|
||||
@ -585,7 +585,7 @@ mux_ack:
|
||||
/* Sending Acknowledgment to EC */
|
||||
mux_ack.port = port_num;
|
||||
|
||||
if (cros_ec_command(typec->ec, 0, EC_CMD_USB_PD_MUX_ACK, &mux_ack,
|
||||
if (cros_ec_cmd(typec->ec, 0, EC_CMD_USB_PD_MUX_ACK, &mux_ack,
|
||||
sizeof(mux_ack), NULL, 0) < 0)
|
||||
dev_warn(typec->dev,
|
||||
"Failed to send Mux ACK to EC for port: %d\n",
|
||||
@ -754,7 +754,7 @@ static int cros_typec_handle_sop_prime_disc(struct cros_typec_data *typec, int p
|
||||
int ret = 0;
|
||||
|
||||
memset(disc, 0, EC_PROTO2_MAX_RESPONSE_SIZE);
|
||||
ret = cros_ec_command(typec->ec, 0, EC_CMD_TYPEC_DISCOVERY, &req, sizeof(req),
|
||||
ret = cros_ec_cmd(typec->ec, 0, EC_CMD_TYPEC_DISCOVERY, &req, sizeof(req),
|
||||
disc, EC_PROTO2_MAX_RESPONSE_SIZE);
|
||||
if (ret < 0) {
|
||||
dev_err(typec->dev, "Failed to get SOP' discovery data for port: %d\n", port_num);
|
||||
@ -837,7 +837,7 @@ static int cros_typec_handle_sop_disc(struct cros_typec_data *typec, int port_nu
|
||||
typec_partner_set_pd_revision(port->partner, pd_revision);
|
||||
|
||||
memset(sop_disc, 0, EC_PROTO2_MAX_RESPONSE_SIZE);
|
||||
ret = cros_ec_command(typec->ec, 0, EC_CMD_TYPEC_DISCOVERY, &req, sizeof(req),
|
||||
ret = cros_ec_cmd(typec->ec, 0, EC_CMD_TYPEC_DISCOVERY, &req, sizeof(req),
|
||||
sop_disc, EC_PROTO2_MAX_RESPONSE_SIZE);
|
||||
if (ret < 0) {
|
||||
dev_err(typec->dev, "Failed to get SOP discovery data for port: %d\n", port_num);
|
||||
@ -870,7 +870,7 @@ static int cros_typec_send_clear_event(struct cros_typec_data *typec, int port_n
|
||||
.clear_events_mask = events_mask,
|
||||
};
|
||||
|
||||
return cros_ec_command(typec->ec, 0, EC_CMD_TYPEC_CONTROL, &req,
|
||||
return cros_ec_cmd(typec->ec, 0, EC_CMD_TYPEC_CONTROL, &req,
|
||||
sizeof(req), NULL, 0);
|
||||
}
|
||||
|
||||
@ -882,7 +882,7 @@ static void cros_typec_handle_status(struct cros_typec_data *typec, int port_num
|
||||
};
|
||||
int ret;
|
||||
|
||||
ret = cros_ec_command(typec->ec, 0, EC_CMD_TYPEC_STATUS, &req, sizeof(req),
|
||||
ret = cros_ec_cmd(typec->ec, 0, EC_CMD_TYPEC_STATUS, &req, sizeof(req),
|
||||
&resp, sizeof(resp));
|
||||
if (ret < 0) {
|
||||
dev_warn(typec->dev, "EC_CMD_TYPEC_STATUS failed for port: %d\n", port_num);
|
||||
@ -960,7 +960,7 @@ static int cros_typec_port_update(struct cros_typec_data *typec, int port_num)
|
||||
req.mux = USB_PD_CTRL_MUX_NO_CHANGE;
|
||||
req.swap = USB_PD_CTRL_SWAP_NONE;
|
||||
|
||||
ret = cros_ec_command(typec->ec, typec->pd_ctrl_ver,
|
||||
ret = cros_ec_cmd(typec->ec, typec->pd_ctrl_ver,
|
||||
EC_CMD_USB_PD_CONTROL, &req, sizeof(req),
|
||||
&resp, sizeof(resp));
|
||||
if (ret < 0)
|
||||
@ -997,9 +997,8 @@ static int cros_typec_get_cmd_version(struct cros_typec_data *typec)
|
||||
|
||||
/* We're interested in the PD control command version. */
|
||||
req_v1.cmd = EC_CMD_USB_PD_CONTROL;
|
||||
ret = cros_ec_command(typec->ec, 1, EC_CMD_GET_CMD_VERSIONS,
|
||||
&req_v1, sizeof(req_v1), &resp,
|
||||
sizeof(resp));
|
||||
ret = cros_ec_cmd(typec->ec, 1, EC_CMD_GET_CMD_VERSIONS,
|
||||
&req_v1, sizeof(req_v1), &resp, sizeof(resp));
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
||||
@ -1090,7 +1089,7 @@ static int cros_typec_probe(struct platform_device *pdev)
|
||||
typec->typec_cmd_supported = cros_ec_check_features(ec_dev, EC_FEATURE_TYPEC_CMD);
|
||||
typec->needs_mux_ack = cros_ec_check_features(ec_dev, EC_FEATURE_TYPEC_MUX_REQUIRE_AP_ACK);
|
||||
|
||||
ret = cros_ec_command(typec->ec, 0, EC_CMD_USB_PD_PORTS, NULL, 0,
|
||||
ret = cros_ec_cmd(typec->ec, 0, EC_CMD_USB_PD_PORTS, NULL, 0,
|
||||
&resp, sizeof(resp));
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
@ -71,7 +71,7 @@ static void cros_usbpd_get_event_and_notify(struct device *dev,
|
||||
}
|
||||
|
||||
/* Check for PD host events on EC. */
|
||||
ret = cros_ec_command(ec_dev, 0, EC_CMD_PD_HOST_EVENT_STATUS,
|
||||
ret = cros_ec_cmd(ec_dev, 0, EC_CMD_PD_HOST_EVENT_STATUS,
|
||||
NULL, 0, &host_event_status, sizeof(host_event_status));
|
||||
if (ret < 0) {
|
||||
dev_warn(dev, "Can't get host event status (err: %d)\n", ret);
|
||||
|
@ -30,7 +30,7 @@ static int cros_ec_regulator_enable(struct regulator_dev *dev)
|
||||
.enable = 1,
|
||||
};
|
||||
|
||||
return cros_ec_command(data->ec_dev, 0, EC_CMD_REGULATOR_ENABLE, &cmd,
|
||||
return cros_ec_cmd(data->ec_dev, 0, EC_CMD_REGULATOR_ENABLE, &cmd,
|
||||
sizeof(cmd), NULL, 0);
|
||||
}
|
||||
|
||||
@ -42,7 +42,7 @@ static int cros_ec_regulator_disable(struct regulator_dev *dev)
|
||||
.enable = 0,
|
||||
};
|
||||
|
||||
return cros_ec_command(data->ec_dev, 0, EC_CMD_REGULATOR_ENABLE, &cmd,
|
||||
return cros_ec_cmd(data->ec_dev, 0, EC_CMD_REGULATOR_ENABLE, &cmd,
|
||||
sizeof(cmd), NULL, 0);
|
||||
}
|
||||
|
||||
@ -55,7 +55,7 @@ static int cros_ec_regulator_is_enabled(struct regulator_dev *dev)
|
||||
struct ec_response_regulator_is_enabled resp;
|
||||
int ret;
|
||||
|
||||
ret = cros_ec_command(data->ec_dev, 0, EC_CMD_REGULATOR_IS_ENABLED, &cmd,
|
||||
ret = cros_ec_cmd(data->ec_dev, 0, EC_CMD_REGULATOR_IS_ENABLED, &cmd,
|
||||
sizeof(cmd), &resp, sizeof(resp));
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
@ -82,7 +82,7 @@ static int cros_ec_regulator_get_voltage(struct regulator_dev *dev)
|
||||
struct ec_response_regulator_get_voltage resp;
|
||||
int ret;
|
||||
|
||||
ret = cros_ec_command(data->ec_dev, 0, EC_CMD_REGULATOR_GET_VOLTAGE, &cmd,
|
||||
ret = cros_ec_cmd(data->ec_dev, 0, EC_CMD_REGULATOR_GET_VOLTAGE, &cmd,
|
||||
sizeof(cmd), &resp, sizeof(resp));
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
@ -108,7 +108,7 @@ static int cros_ec_regulator_set_voltage(struct regulator_dev *dev, int min_uV,
|
||||
if (min_mV > max_mV)
|
||||
return -EINVAL;
|
||||
|
||||
return cros_ec_command(data->ec_dev, 0, EC_CMD_REGULATOR_SET_VOLTAGE, &cmd,
|
||||
return cros_ec_cmd(data->ec_dev, 0, EC_CMD_REGULATOR_SET_VOLTAGE, &cmd,
|
||||
sizeof(cmd), NULL, 0);
|
||||
}
|
||||
|
||||
@ -130,7 +130,7 @@ static int cros_ec_regulator_init_info(struct device *dev,
|
||||
struct ec_response_regulator_get_info resp;
|
||||
int ret;
|
||||
|
||||
ret = cros_ec_command(data->ec_dev, 0, EC_CMD_REGULATOR_GET_INFO, &cmd,
|
||||
ret = cros_ec_cmd(data->ec_dev, 0, EC_CMD_REGULATOR_GET_INFO, &cmd,
|
||||
sizeof(cmd), &resp, sizeof(resp));
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
@ -231,7 +231,7 @@ bool cros_ec_check_features(struct cros_ec_dev *ec, int feature);
|
||||
|
||||
int cros_ec_get_sensor_count(struct cros_ec_dev *ec);
|
||||
|
||||
int cros_ec_command(struct cros_ec_device *ec_dev, unsigned int version, int command, void *outdata,
|
||||
int cros_ec_cmd(struct cros_ec_device *ec_dev, unsigned int version, int command, void *outdata,
|
||||
int outsize, void *indata, int insize);
|
||||
|
||||
/**
|
||||
|
Loading…
Reference in New Issue