staging: r8188eu: update status before wps success blinking
Always update the status variables in rtw_led_control when we start blinking to show that wps was successful. The if statements are not necessary. Tested-by: Philipp Hortmann <philipp.g.hortmann@gmail.com> # Edimax N150 Signed-off-by: Martin Kaiser <martin@kaiser.cx> Link: https://lore.kernel.org/r/20220918175700.215170-3-martin@kaiser.cx Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
cb2b346013
commit
b08d89994d
@ -324,20 +324,11 @@ void rtw_led_control(struct adapter *padapter, enum LED_CTL_MODE LedAction)
|
||||
case LED_CTL_STOP_WPS:
|
||||
cancel_delayed_work(&pLed->blink_work);
|
||||
|
||||
if (pLed->bLedNoLinkBlinkInProgress)
|
||||
pLed->bLedNoLinkBlinkInProgress = false;
|
||||
|
||||
if (pLed->bLedLinkBlinkInProgress)
|
||||
pLed->bLedLinkBlinkInProgress = false;
|
||||
|
||||
if (pLed->bLedBlinkInProgress)
|
||||
pLed->bLedBlinkInProgress = false;
|
||||
|
||||
if (pLed->bLedScanBlinkInProgress)
|
||||
pLed->bLedScanBlinkInProgress = false;
|
||||
|
||||
if (!pLed->bLedWPSBlinkInProgress)
|
||||
pLed->bLedWPSBlinkInProgress = true;
|
||||
pLed->bLedNoLinkBlinkInProgress = false;
|
||||
pLed->bLedLinkBlinkInProgress = false;
|
||||
pLed->bLedBlinkInProgress = false;
|
||||
pLed->bLedScanBlinkInProgress = false;
|
||||
pLed->bLedWPSBlinkInProgress = true;
|
||||
|
||||
pLed->CurrLedState = LED_BLINK_WPS_STOP;
|
||||
if (pLed->bLedOn) {
|
||||
|