ixgbe: fix bit toggled for 82599 reset fix.
The current code doesn't toggle the correct bit to reset the data pipeline on Restart_AN assertion. This patch corrects that. Signed-off-by: Don Skidmore <donald.c.skidmore@intel.com> Tested-by: Phil Schmitt <phillip.j.schmitt@intel.com> Signed-off-by: Aaron Brown <aaron.f.brown@intel.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
429d6a3be9
commit
9f4d278ffb
@ -2395,7 +2395,8 @@ static s32 ixgbe_reset_pipeline_82599(struct ixgbe_hw *hw)
|
||||
autoc_reg |= IXGBE_AUTOC_AN_RESTART;
|
||||
|
||||
/* Write AUTOC register with toggled LMS[2] bit and Restart_AN */
|
||||
IXGBE_WRITE_REG(hw, IXGBE_AUTOC, autoc_reg ^ IXGBE_AUTOC_LMS_1G_AN);
|
||||
IXGBE_WRITE_REG(hw, IXGBE_AUTOC,
|
||||
autoc_reg ^ (0x4 << IXGBE_AUTOC_LMS_SHIFT));
|
||||
|
||||
/* Wait for AN to leave state 0 */
|
||||
for (i = 0; i < 10; i++) {
|
||||
|