power: supply: sbs-battery: use correct flags field
the type flag is stored in the chip->flags field not in the
client->flags field. This currently leads to never using the ti
specific health function as client->flags doesn't use that bit.
So it's always falling back to the general one.
Fixes: 76b16f4cdf
("power: supply: sbs-battery: don't assume MANUFACTURER_DATA formats")
Cc: <stable@vger.kernel.org>
Signed-off-by: Michael Nosthoff <committed@heine.so>
Reviewed-by: Brian Norris <briannorris@chromium.org>
Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
fa7da7449e
commit
99956a9e08
@ -620,7 +620,7 @@ static int sbs_get_property(struct power_supply *psy,
|
||||
switch (psp) {
|
||||
case POWER_SUPPLY_PROP_PRESENT:
|
||||
case POWER_SUPPLY_PROP_HEALTH:
|
||||
if (client->flags & SBS_FLAGS_TI_BQ20Z75)
|
||||
if (chip->flags & SBS_FLAGS_TI_BQ20Z75)
|
||||
ret = sbs_get_ti_battery_presence_and_health(client,
|
||||
psp, val);
|
||||
else
|
||||
|