net: phy: marvell: fix m88e1011_set_downshift
Changing downshift params without software reset has no effect,
so call genphy_soft_reset() after change downshift params.
As the datasheet says:
Changes to these bits are disruptive to the normal operation therefore,
any changes to these registers must be followed by software reset
to take effect.
Fixes: 911af5e149
("net: phy: marvell: fix downshift function naming")
Signed-off-by: Maxim Kochetkov <fido_max@inbox.ru>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
parent
eefb45eef5
commit
990875b299
@ -1025,22 +1025,28 @@ static int m88e1011_get_downshift(struct phy_device *phydev, u8 *data)
|
||||
|
||||
static int m88e1011_set_downshift(struct phy_device *phydev, u8 cnt)
|
||||
{
|
||||
int val;
|
||||
int val, err;
|
||||
|
||||
if (cnt > MII_M1011_PHY_SCR_DOWNSHIFT_MAX)
|
||||
return -E2BIG;
|
||||
|
||||
if (!cnt)
|
||||
return phy_clear_bits(phydev, MII_M1011_PHY_SCR,
|
||||
MII_M1011_PHY_SCR_DOWNSHIFT_EN);
|
||||
if (!cnt) {
|
||||
err = phy_clear_bits(phydev, MII_M1011_PHY_SCR,
|
||||
MII_M1011_PHY_SCR_DOWNSHIFT_EN);
|
||||
} else {
|
||||
val = MII_M1011_PHY_SCR_DOWNSHIFT_EN;
|
||||
val |= FIELD_PREP(MII_M1011_PHY_SCR_DOWNSHIFT_MASK, cnt - 1);
|
||||
|
||||
val = MII_M1011_PHY_SCR_DOWNSHIFT_EN;
|
||||
val |= FIELD_PREP(MII_M1011_PHY_SCR_DOWNSHIFT_MASK, cnt - 1);
|
||||
err = phy_modify(phydev, MII_M1011_PHY_SCR,
|
||||
MII_M1011_PHY_SCR_DOWNSHIFT_EN |
|
||||
MII_M1011_PHY_SCR_DOWNSHIFT_MASK,
|
||||
val);
|
||||
}
|
||||
|
||||
return phy_modify(phydev, MII_M1011_PHY_SCR,
|
||||
MII_M1011_PHY_SCR_DOWNSHIFT_EN |
|
||||
MII_M1011_PHY_SCR_DOWNSHIFT_MASK,
|
||||
val);
|
||||
if (err < 0)
|
||||
return err;
|
||||
|
||||
return genphy_soft_reset(phydev);
|
||||
}
|
||||
|
||||
static int m88e1011_get_tunable(struct phy_device *phydev,
|
||||
|