brcmfmac: change rx_seq check log from error print to debug print

The bus rx sequence is not in order because that control and event
frames always cause immediate send, but data frames may be held
for glomming in firmware side. It is not actually an error as the
packets are still processed even if the RX sequence is not in order.
Therefor the error message is rephrased and changed to a debug
message.

Reviewed-by: Arend Van Spriel <arend@broadcom.com>
Signed-off-by: Wright Feng <wright.feng@broadcom.com>
Signed-off-by: Arend van Spriel <arend.vanspriel@broadcom.com>
Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
This commit is contained in:
Wright Feng 2016-06-03 23:31:11 +02:00 committed by Kalle Valo
parent 43819926ed
commit 98aff6c005

View File

@ -1384,8 +1384,7 @@ static int brcmf_sdio_hdparse(struct brcmf_sdio *bus, u8 *header,
return -ENXIO;
}
if (rd->seq_num != rx_seq) {
brcmf_err("seq %d: sequence number error, expect %d\n",
rx_seq, rd->seq_num);
brcmf_dbg(SDIO, "seq %d, expected %d\n", rx_seq, rd->seq_num);
bus->sdcnt.rx_badseq++;
rd->seq_num = rx_seq;
}