forked from Minki/linux
drm/i915/gvt: Fix cmd length check for MI_ATOMIC
Correct valid command length check for MI_ATOMIC, need to check inline
data available field instead of operand data length for whole command.
Fixes: 00a33be406
("drm/i915/gvt: Add valid length check for MI variable commands")
Reported-by: Alex Williamson <alex.williamson@redhat.com>
Acked-by: Gao Fred <fred.gao@intel.com>
Cc: stable@vger.kernel.org
Signed-off-by: Zhenyu Wang <zhenyuw@linux.intel.com>
This commit is contained in:
parent
68421940b0
commit
92b1aa773f
@ -1599,9 +1599,9 @@ static int cmd_handler_mi_op_2f(struct parser_exec_state *s)
|
||||
if (!(cmd_val(s, 0) & (1 << 22)))
|
||||
return ret;
|
||||
|
||||
/* check if QWORD */
|
||||
if (DWORD_FIELD(0, 20, 19) == 1)
|
||||
valid_len += 8;
|
||||
/* check inline data */
|
||||
if (cmd_val(s, 0) & BIT(18))
|
||||
valid_len = CMD_LEN(9);
|
||||
ret = gvt_check_valid_cmd_length(cmd_length(s),
|
||||
valid_len);
|
||||
if (ret)
|
||||
|
Loading…