iwlwifi: make sure runtime calibration is enabled after association
Clear the "start calib" flag only for new association, The flag will be set in post_associate function to trigger the runtime calibration. Set this flag to "0" will stop the runtime sensitivity calibration Signed-off-by: Wey-Yi Guy <wey-yi.w.guy@intel.com>
This commit is contained in:
parent
ea196fdbb9
commit
8f1d968721
@ -226,9 +226,8 @@ int iwl_commit_rxon(struct iwl_priv *priv, struct iwl_rxon_context *ctx)
|
|||||||
return ret;
|
return ret;
|
||||||
}
|
}
|
||||||
}
|
}
|
||||||
|
|
||||||
priv->start_calib = 0;
|
|
||||||
if (new_assoc) {
|
if (new_assoc) {
|
||||||
|
priv->start_calib = 0;
|
||||||
/* Apply the new configuration
|
/* Apply the new configuration
|
||||||
* RXON assoc doesn't clear the station table in uCode,
|
* RXON assoc doesn't clear the station table in uCode,
|
||||||
*/
|
*/
|
||||||
|