ARM: shmobile: Enable PM and PM_GENERIC_DOMAINS for SoCs with PM Domains

All supported Renesas ARM SoCs (except for Emma Mobile EV2) have clock
domains. Some SoCs also have power domains. To ensure proper operation
of on-SoC modules, module clocks must be ungated, and power domains must
be powered up when needed.

Currently the user can choose to build a kernel with power management
enabled or disabled:
  - If CONFIG_PM=y, power domains and/or module clocks are handled
    dynamically by Runtime PM and the generic power domain.
  - If CONFIG_PM=n, power domains are assumed to be powered up by reset
    state or by the boot loader, and module clocks are handled by the
    legacy clock domain on driver (un)bind.
    The latter is implemented using a platform bus notifier, which
    applies not only to all on-SoC devices, but to all platform devices
    present in the system.

To remove the dependency on implicit assumptions, and to get rid of the
peculiarities of the legacy clock domain, enable CONFIG_PM and
CONFIG_PM_GENERIC_DOMAINS unconditionally, for all Renesas ARM SoCs with
clock and/or power domains.

This does cause an increase in kernel size.  Given bloat-o-meter reports
a modest increase of 26 KiB for an RZ/A1H kernel, this should not be a
problem, even when used on RZ/A1H with XIP and internal RAM only.

Signed-off-by: Geert Uytterhoeven <geert+renesas@glider.be>
Signed-off-by: Simon Horman <horms+renesas@verge.net.au>
This commit is contained in:
Geert Uytterhoeven 2016-02-16 16:31:49 +01:00 committed by Simon Horman
parent c58b31aa46
commit 71d076ceb2

View File

@ -6,28 +6,30 @@ config ARCH_SHMOBILE_MULTI
config PM_RCAR config PM_RCAR
bool bool
select PM_GENERIC_DOMAINS if PM select PM
select PM_GENERIC_DOMAINS
config PM_RMOBILE config PM_RMOBILE
bool bool
select PM
select PM_GENERIC_DOMAINS select PM_GENERIC_DOMAINS
config ARCH_RCAR_GEN1 config ARCH_RCAR_GEN1
bool bool
select PM_RCAR if PM || SMP select PM_RCAR
select RENESAS_INTC_IRQPIN select RENESAS_INTC_IRQPIN
select SYS_SUPPORTS_SH_TMU select SYS_SUPPORTS_SH_TMU
config ARCH_RCAR_GEN2 config ARCH_RCAR_GEN2
bool bool
select PM_RCAR if PM || SMP select PM_RCAR
select RENESAS_IRQC select RENESAS_IRQC
select SYS_SUPPORTS_SH_CMT select SYS_SUPPORTS_SH_CMT
select PCI_DOMAINS if PCI select PCI_DOMAINS if PCI
config ARCH_RMOBILE config ARCH_RMOBILE
bool bool
select PM_RMOBILE if PM select PM_RMOBILE
select SYS_SUPPORTS_SH_CMT select SYS_SUPPORTS_SH_CMT
select SYS_SUPPORTS_SH_TMU select SYS_SUPPORTS_SH_TMU
@ -55,7 +57,8 @@ config ARCH_EMEV2
config ARCH_R7S72100 config ARCH_R7S72100
bool "RZ/A1H (R7S72100)" bool "RZ/A1H (R7S72100)"
select PM_GENERIC_DOMAINS if PM select PM
select PM_GENERIC_DOMAINS
select SYS_SUPPORTS_SH_MTU2 select SYS_SUPPORTS_SH_MTU2
config ARCH_R8A73A4 config ARCH_R8A73A4