net: Fix routing tables with id > 255 for legacy software

Most legacy software do not like tables > 255 as rtm_table is u8
so tb_id is sent &0xff and it is possible to mismatch for example
table 510 with table 254 (main).

This patch introduces RT_TABLE_COMPAT=252 so the code uses it if
tb_id > 255. It makes such old applications happy, new
ones are still able to use RTA_TABLE to get a proper table id.

Signed-off-by: Krzysztof Piotr Oledzki <ole@ans.pl>
Acked-by: Patrick McHardy <kaber@trash.net>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Krzysztof Piotr Oledzki 2008-06-10 15:44:49 -07:00 committed by David S. Miller
parent 99c6f60e72
commit 709772e6e0
2 changed files with 5 additions and 1 deletions

View File

@ -246,6 +246,7 @@ enum rt_class_t
{
RT_TABLE_UNSPEC=0,
/* User defined values */
RT_TABLE_COMPAT=252,
RT_TABLE_DEFAULT=253,
RT_TABLE_MAIN=254,
RT_TABLE_LOCAL=255,

View File

@ -960,7 +960,10 @@ int fib_dump_info(struct sk_buff *skb, u32 pid, u32 seq, int event,
rtm->rtm_dst_len = dst_len;
rtm->rtm_src_len = 0;
rtm->rtm_tos = tos;
rtm->rtm_table = tb_id;
if (tb_id < 256)
rtm->rtm_table = tb_id;
else
rtm->rtm_table = RT_TABLE_COMPAT;
NLA_PUT_U32(skb, RTA_TABLE, tb_id);
rtm->rtm_type = type;
rtm->rtm_flags = fi->fib_flags;