dt-bindings: devfreq: tegra30-actmon: Add cooling-cells
The ACTMON watches activity of memory clients. Decisions about a minimum required frequency are made based on the info from ACTMON. We can use ACTMON as a thermal cooling device by limiting the required frequency. Document new cooling-cells property of NVIDIA Tegra ACTMON hardware unit. Reviewed-by: Rob Herring <robh@kernel.org> Acked-by: Chanwoo Choi <cw00.choi@samsung.com> Acked-by: Thierry Reding <treding@nvidia.com> Signed-off-by: Dmitry Osipenko <digetx@gmail.com> Signed-off-by: Chanwoo Choi <cw00.choi@samsung.com>
This commit is contained in:
parent
271ca53cb0
commit
6b61f55ecb
@ -63,6 +63,9 @@ properties:
|
||||
Should contain freqs and voltages and opp-supported-hw property, which
|
||||
is a bitfield indicating SoC speedo ID mask.
|
||||
|
||||
"#cooling-cells":
|
||||
const: 2
|
||||
|
||||
required:
|
||||
- compatible
|
||||
- reg
|
||||
@ -74,6 +77,7 @@ required:
|
||||
- interconnects
|
||||
- interconnect-names
|
||||
- operating-points-v2
|
||||
- "#cooling-cells"
|
||||
|
||||
additionalProperties: false
|
||||
|
||||
@ -118,4 +122,5 @@ examples:
|
||||
operating-points-v2 = <&dvfs_opp_table>;
|
||||
interconnects = <&mc TEGRA30_MC_MPCORER &emc>;
|
||||
interconnect-names = "cpu-read";
|
||||
#cooling-cells = <2>;
|
||||
};
|
||||
|
Loading…