forked from Minki/linux
usb: pl2303: also use the divisor based baud rate encoding method for baud rates < 115200 with HX chips
Now that the divisor based baud rate encoding method has been fixed and extended, it can also be used for baud rates < 115200 baud with HX chips. This makes it possible to adjust the baud rate almost continuously instead of just beeing able to select between 16 fixed standard values. Tested with a PL2303HX 04463A (week 46, 2004, rev 3A). Signed-off-by: Frank Schäfer <fschaefer.oss@googlemail.com> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
b5c16c6a03
commit
61fa8d694b
@ -395,7 +395,7 @@ static void pl2303_encode_baudrate(struct tty_struct *tty,
|
||||
* 2) Divisor based method: encodes a divisor to a base value (12MHz*32)
|
||||
* => supported by HX chips (and likely not by type_0/1 chips)
|
||||
*/
|
||||
if (type != HX || baud <= 115200)
|
||||
if (type != HX)
|
||||
baud = pl2303_baudrate_encode_direct(baud, type, buf);
|
||||
else
|
||||
baud = pl2303_baudrate_encode_divisor(baud, type, buf);
|
||||
|