forked from Minki/linux
thermal: cpu_cooling: alignment improvements
Improve code readiness by changing alignments so that they match open parenthesis, like checkpatch.pl --strict suggests. Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This commit is contained in:
parent
ef5e2124ec
commit
5fda7f680a
@ -270,7 +270,7 @@ static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
|
||||
* cooling state).
|
||||
*/
|
||||
static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
|
||||
unsigned long cooling_state)
|
||||
unsigned long cooling_state)
|
||||
{
|
||||
unsigned int cpuid, clip_freq;
|
||||
struct cpumask *mask = &cpufreq_device->allowed_cpus;
|
||||
@ -312,7 +312,7 @@ static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
|
||||
* Return: 0 (success)
|
||||
*/
|
||||
static int cpufreq_thermal_notifier(struct notifier_block *nb,
|
||||
unsigned long event, void *data)
|
||||
unsigned long event, void *data)
|
||||
{
|
||||
struct cpufreq_policy *policy = data;
|
||||
unsigned long max_freq = 0;
|
||||
@ -425,8 +425,8 @@ static struct notifier_block thermal_cpufreq_notifier_block = {
|
||||
* Return: a valid struct thermal_cooling_device pointer on success,
|
||||
* on failure, it returns a corresponding ERR_PTR().
|
||||
*/
|
||||
struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
const struct cpumask *clip_cpus)
|
||||
struct thermal_cooling_device *
|
||||
cpufreq_cooling_register(const struct cpumask *clip_cpus)
|
||||
{
|
||||
struct thermal_cooling_device *cool_dev;
|
||||
struct cpufreq_cooling_device *cpufreq_dev = NULL;
|
||||
@ -445,12 +445,12 @@ struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
max = policy.cpuinfo.max_freq;
|
||||
} else {
|
||||
if (min != policy.cpuinfo.min_freq ||
|
||||
max != policy.cpuinfo.max_freq)
|
||||
max != policy.cpuinfo.max_freq)
|
||||
return ERR_PTR(-EINVAL);
|
||||
}
|
||||
}
|
||||
cpufreq_dev = kzalloc(sizeof(struct cpufreq_cooling_device),
|
||||
GFP_KERNEL);
|
||||
GFP_KERNEL);
|
||||
if (!cpufreq_dev)
|
||||
return ERR_PTR(-ENOMEM);
|
||||
|
||||
@ -466,7 +466,7 @@ struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
cpufreq_dev->id);
|
||||
|
||||
cool_dev = thermal_cooling_device_register(dev_name, cpufreq_dev,
|
||||
&cpufreq_cooling_ops);
|
||||
&cpufreq_cooling_ops);
|
||||
if (!cool_dev) {
|
||||
release_idr(&cpufreq_idr, cpufreq_dev->id);
|
||||
kfree(cpufreq_dev);
|
||||
@ -479,7 +479,7 @@ struct thermal_cooling_device *cpufreq_cooling_register(
|
||||
/* Register the notifier for first cpufreq cooling device */
|
||||
if (cpufreq_dev_count == 0)
|
||||
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
cpufreq_dev_count++;
|
||||
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
@ -504,8 +504,7 @@ void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
||||
/* Unregister the notifier for the last cpufreq cooling device */
|
||||
if (cpufreq_dev_count == 0)
|
||||
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
|
||||
CPUFREQ_POLICY_NOTIFIER);
|
||||
mutex_unlock(&cooling_cpufreq_lock);
|
||||
|
||||
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
|
||||
|
Loading…
Reference in New Issue