rx51_battery: Fix reporting temperature

This patch fixing units (1/10 °C) in which is temperature reported.

Signed-off-by: Pali Rohár <pali.rohar@gmail.com>
Signed-off-by: Anton Vorontsov <anton@enomsg.org>
This commit is contained in:
Pali Rohár 2013-03-28 17:42:23 +01:00 committed by Anton Vorontsov
parent 0bbb06ed56
commit 59584857be

View File

@ -119,7 +119,7 @@ static int rx51_battery_read_temperature(struct rx51_device_info *di)
/* First check for temperature in first direct table */
if (raw < ARRAY_SIZE(rx51_temp_table1))
return rx51_temp_table1[raw] * 100;
return rx51_temp_table1[raw] * 10;
/* Binary search RAW value in second inverse table */
while (max - min > 1) {
@ -132,7 +132,7 @@ static int rx51_battery_read_temperature(struct rx51_device_info *di)
break;
}
return (rx51_temp_table2_first - min) * 100;
return (rx51_temp_table2_first - min) * 10;
}
/*