ath9k: Initialize MCI state correctly

The MCI configuration values are assigned
in ath9k_hw_btcoex_init_mci() which are used
by the MCI reset routine. When initializing
BTCOEX/MCI, ath_mci_setup() ends up using
uninitialized data. Fix this by setting up
the configuration parameters before issuing
a MCI reset.

Signed-off-by: Sujith Manoharan <c_manoha@qca.qualcomm.com>
Signed-off-by: Kalle Valo <kvalo@codeaurora.org>
This commit is contained in:
Sujith Manoharan 2015-03-01 11:53:45 +05:30 committed by Kalle Valo
parent 44b9b56e50
commit 510baea1e4

View File

@ -415,12 +415,11 @@ int ath9k_init_btcoex(struct ath_softc *sc)
if (ath9k_hw_mci_is_enabled(ah)) { if (ath9k_hw_mci_is_enabled(ah)) {
sc->btcoex.duty_cycle = ATH_BTCOEX_DEF_DUTY_CYCLE; sc->btcoex.duty_cycle = ATH_BTCOEX_DEF_DUTY_CYCLE;
INIT_LIST_HEAD(&sc->btcoex.mci.info); INIT_LIST_HEAD(&sc->btcoex.mci.info);
ath9k_hw_btcoex_init_mci(ah);
r = ath_mci_setup(sc); r = ath_mci_setup(sc);
if (r) if (r)
return r; return r;
ath9k_hw_btcoex_init_mci(ah);
} }
break; break;