Bluetooth: mgmt: Fix update_eir/class with HCI_AUTO_OFF flag set
If we're powered but still have the HCI_AUTO_OFF flag set the update_eir and update_class functions should not do anything. Additionally these functions need to be called when the flag is finally cleared through set_powered or when powering on for real. Signed-off-by: Johan Hedberg <johan.hedberg@intel.com> Acked-by: Gustavo F. Padovan <padovan@profusion.mobi> Acked-by: Marcel Holtmann <marcel@holtmann.org>
This commit is contained in:
parent
69775ff6d1
commit
504c8dcd6b
@ -532,7 +532,7 @@ static int update_eir(struct hci_dev *hdev)
|
||||
{
|
||||
struct hci_cp_write_eir cp;
|
||||
|
||||
if (!test_bit(HCI_UP, &hdev->flags))
|
||||
if (!hdev_is_powered(hdev))
|
||||
return 0;
|
||||
|
||||
if (!(hdev->features[6] & LMP_EXT_INQ))
|
||||
@ -573,7 +573,7 @@ static int update_class(struct hci_dev *hdev)
|
||||
|
||||
BT_DBG("%s", hdev->name);
|
||||
|
||||
if (!test_bit(HCI_UP, &hdev->flags))
|
||||
if (!hdev_is_powered(hdev))
|
||||
return 0;
|
||||
|
||||
if (test_bit(HCI_SERVICE_CACHE, &hdev->dev_flags))
|
||||
@ -3121,6 +3121,9 @@ int mgmt_powered(struct hci_dev *hdev, u8 powered)
|
||||
|
||||
if (scan)
|
||||
hci_send_cmd(hdev, HCI_OP_WRITE_SCAN_ENABLE, 1, &scan);
|
||||
|
||||
update_class(hdev);
|
||||
update_eir(hdev);
|
||||
} else {
|
||||
u8 status = ENETDOWN;
|
||||
mgmt_pending_foreach(0, hdev, cmd_status_rsp, &status);
|
||||
|