iio/gyro/bmg160: Use millidegrees for temperature scale
Standard unit for temperature is millidegrees Celcius, whereas this driver was reporting in degrees. Fix the scale factor in the driver. Signed-off-by: Mike Looijmans <mike.looijmans@topic.nl> Cc: <Stable@vger.kernel.org> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
0a8a29be49
commit
40a7198a4a
@ -582,11 +582,10 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
|
||||
case IIO_CHAN_INFO_LOW_PASS_FILTER_3DB_FREQUENCY:
|
||||
return bmg160_get_filter(data, val);
|
||||
case IIO_CHAN_INFO_SCALE:
|
||||
*val = 0;
|
||||
switch (chan->type) {
|
||||
case IIO_TEMP:
|
||||
*val2 = 500000;
|
||||
return IIO_VAL_INT_PLUS_MICRO;
|
||||
*val = 500;
|
||||
return IIO_VAL_INT;
|
||||
case IIO_ANGL_VEL:
|
||||
{
|
||||
int i;
|
||||
@ -594,6 +593,7 @@ static int bmg160_read_raw(struct iio_dev *indio_dev,
|
||||
for (i = 0; i < ARRAY_SIZE(bmg160_scale_table); ++i) {
|
||||
if (bmg160_scale_table[i].dps_range ==
|
||||
data->dps_range) {
|
||||
*val = 0;
|
||||
*val2 = bmg160_scale_table[i].scale;
|
||||
return IIO_VAL_INT_PLUS_MICRO;
|
||||
}
|
||||
|
Loading…
Reference in New Issue