staging:iio:dac:ad5504: Use strtobool for boolean values
Use strtobool for parsing the powerdown value instead of strict_strtol, since the powerdown attribute is a boolean value. Signed-off-by: Lars-Peter Clausen <lars@metafoo.de> Acked-by: Jonathan Cameron <jic23@kernel.org> Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
parent
159fe695ae
commit
3bbbf150ff
@ -147,20 +147,18 @@ static ssize_t ad5504_write_dac_powerdown(struct iio_dev *indio_dev,
|
|||||||
uintptr_t private, const struct iio_chan_spec *chan, const char *buf,
|
uintptr_t private, const struct iio_chan_spec *chan, const char *buf,
|
||||||
size_t len)
|
size_t len)
|
||||||
{
|
{
|
||||||
long readin;
|
bool pwr_down;
|
||||||
int ret;
|
int ret;
|
||||||
struct ad5504_state *st = iio_priv(indio_dev);
|
struct ad5504_state *st = iio_priv(indio_dev);
|
||||||
|
|
||||||
ret = strict_strtol(buf, 10, &readin);
|
ret = strtobool(buf, &pwr_down);
|
||||||
if (ret)
|
if (ret)
|
||||||
return ret;
|
return ret;
|
||||||
|
|
||||||
if (readin == 0)
|
if (pwr_down)
|
||||||
st->pwr_down_mask |= (1 << chan->channel);
|
st->pwr_down_mask |= (1 << chan->channel);
|
||||||
else if (readin == 1)
|
|
||||||
st->pwr_down_mask &= ~(1 << chan->channel);
|
|
||||||
else
|
else
|
||||||
ret = -EINVAL;
|
st->pwr_down_mask &= ~(1 << chan->channel);
|
||||||
|
|
||||||
ret = ad5504_spi_write(st->spi, AD5504_ADDR_CTRL,
|
ret = ad5504_spi_write(st->spi, AD5504_ADDR_CTRL,
|
||||||
AD5504_DAC_PWRDWN_MODE(st->pwr_down_mode) |
|
AD5504_DAC_PWRDWN_MODE(st->pwr_down_mode) |
|
||||||
|