iio: adc: ti_am335x_adc: Add the scale information
Without the scale, the values returned to the user are just a picture of the input voltage against the full scale range of the ADC. We need to provide the actual conversion factor to get milli-Volts values. Signed-off-by: Miquel Raynal <miquel.raynal@bootlin.com> Acked-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> Signed-off-by: Lee Jones <lee.jones@linaro.org> Link: https://lore.kernel.org/r/20211015081506.933180-45-miquel.raynal@bootlin.com
This commit is contained in:
parent
789e5ebcc6
commit
3af9935499
@ -417,6 +417,7 @@ static int tiadc_channel_init(struct device *dev, struct iio_dev *indio_dev,
|
||||
chan->indexed = 1;
|
||||
chan->channel = adc_dev->channel_line[i];
|
||||
chan->info_mask_separate = BIT(IIO_CHAN_INFO_RAW);
|
||||
chan->info_mask_shared_by_type = BIT(IIO_CHAN_INFO_SCALE);
|
||||
chan->datasheet_name = chan_name_ain[chan->channel];
|
||||
chan->scan_index = i;
|
||||
chan->scan_type.sign = 'u';
|
||||
@ -441,6 +442,23 @@ static int tiadc_read_raw(struct iio_dev *indio_dev,
|
||||
unsigned long timeout;
|
||||
int ret;
|
||||
|
||||
switch (mask) {
|
||||
case IIO_CHAN_INFO_RAW:
|
||||
break;
|
||||
case IIO_CHAN_INFO_SCALE:
|
||||
switch (chan->type) {
|
||||
case IIO_VOLTAGE:
|
||||
*val = 1800;
|
||||
*val2 = chan->scan_type.realbits;
|
||||
return IIO_VAL_FRACTIONAL_LOG2;
|
||||
default:
|
||||
return -EINVAL;
|
||||
}
|
||||
break;
|
||||
default:
|
||||
return -EINVAL;
|
||||
}
|
||||
|
||||
if (iio_buffer_enabled(indio_dev))
|
||||
return -EBUSY;
|
||||
|
||||
|