forked from Minki/linux
mwifiex: shorten per channel scan time
Currently the scan time per channel for active scanning is set to 200ms. It takes quite a while to finsh scanning on all channels, especially with a dual band configuration. Change the per channel scan time settings to the following values: passive scan: 110ms active scan: 30ms specific scan: 30ms Above settings have been tested on x86 and arm platforms. Signed-off-by: Bing Zhao <bzhao@marvell.com> Signed-off-by: Amitkumar Karwar <akarwar@marvell.com> Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
parent
b6038961df
commit
38e8b7d977
@ -79,9 +79,9 @@ enum {
|
||||
|
||||
#define SCAN_BEACON_ENTRY_PAD 6
|
||||
|
||||
#define MWIFIEX_PASSIVE_SCAN_CHAN_TIME 200
|
||||
#define MWIFIEX_ACTIVE_SCAN_CHAN_TIME 200
|
||||
#define MWIFIEX_SPECIFIC_SCAN_CHAN_TIME 110
|
||||
#define MWIFIEX_PASSIVE_SCAN_CHAN_TIME 110
|
||||
#define MWIFIEX_ACTIVE_SCAN_CHAN_TIME 30
|
||||
#define MWIFIEX_SPECIFIC_SCAN_CHAN_TIME 30
|
||||
|
||||
#define SCAN_RSSI(RSSI) (0x100 - ((u8)(RSSI)))
|
||||
|
||||
|