mwifiex: shorten per channel scan time

Currently the scan time per channel for active scanning is set to
200ms. It takes quite a while to finsh scanning on all channels,
especially with a dual band configuration.

Change the per channel scan time settings to the following values:

passive scan: 110ms
active scan: 30ms
specific scan: 30ms

Above settings have been tested on x86 and arm platforms.

Signed-off-by: Bing Zhao <bzhao@marvell.com>
Signed-off-by: Amitkumar Karwar <akarwar@marvell.com>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Bing Zhao 2012-06-06 21:12:40 -07:00 committed by John W. Linville
parent b6038961df
commit 38e8b7d977

View File

@ -79,9 +79,9 @@ enum {
#define SCAN_BEACON_ENTRY_PAD 6
#define MWIFIEX_PASSIVE_SCAN_CHAN_TIME 200
#define MWIFIEX_ACTIVE_SCAN_CHAN_TIME 200
#define MWIFIEX_SPECIFIC_SCAN_CHAN_TIME 110
#define MWIFIEX_PASSIVE_SCAN_CHAN_TIME 110
#define MWIFIEX_ACTIVE_SCAN_CHAN_TIME 30
#define MWIFIEX_SPECIFIC_SCAN_CHAN_TIME 30
#define SCAN_RSSI(RSSI) (0x100 - ((u8)(RSSI)))