power: supply: sbs-battery: combine get_presence_and_health
This patch enables calling sbs_get_battery_presence_and_health() without checking its chip type. No functional changes. Signed-off-by: Ikjoon Jang <ikjn@chromium.org> Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
parent
52bef41f60
commit
2c4bf69834
@ -473,37 +473,6 @@ static bool sbs_bat_needs_calibration(struct i2c_client *client)
|
||||
return !!(ret & BIT(7));
|
||||
}
|
||||
|
||||
static int sbs_get_battery_presence_and_health(
|
||||
struct i2c_client *client, enum power_supply_property psp,
|
||||
union power_supply_propval *val)
|
||||
{
|
||||
int ret;
|
||||
|
||||
/* Dummy command; if it succeeds, battery is present. */
|
||||
ret = sbs_read_word_data(client, sbs_data[REG_STATUS].addr);
|
||||
|
||||
if (ret < 0) { /* battery not present*/
|
||||
if (psp == POWER_SUPPLY_PROP_PRESENT) {
|
||||
val->intval = 0;
|
||||
return 0;
|
||||
}
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (psp == POWER_SUPPLY_PROP_PRESENT)
|
||||
val->intval = 1; /* battery present */
|
||||
else { /* POWER_SUPPLY_PROP_HEALTH */
|
||||
if (sbs_bat_needs_calibration(client)) {
|
||||
val->intval = POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED;
|
||||
} else {
|
||||
/* SBS spec doesn't have a general health command. */
|
||||
val->intval = POWER_SUPPLY_HEALTH_UNKNOWN;
|
||||
}
|
||||
}
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int sbs_get_ti_battery_presence_and_health(
|
||||
struct i2c_client *client, enum power_supply_property psp,
|
||||
union power_supply_propval *val)
|
||||
@ -562,6 +531,41 @@ static int sbs_get_ti_battery_presence_and_health(
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int sbs_get_battery_presence_and_health(
|
||||
struct i2c_client *client, enum power_supply_property psp,
|
||||
union power_supply_propval *val)
|
||||
{
|
||||
struct sbs_info *chip = i2c_get_clientdata(client);
|
||||
int ret;
|
||||
|
||||
if (chip->flags & SBS_FLAGS_TI_BQ20ZX5)
|
||||
return sbs_get_ti_battery_presence_and_health(client, psp, val);
|
||||
|
||||
/* Dummy command; if it succeeds, battery is present. */
|
||||
ret = sbs_read_word_data(client, sbs_data[REG_STATUS].addr);
|
||||
|
||||
if (ret < 0) { /* battery not present*/
|
||||
if (psp == POWER_SUPPLY_PROP_PRESENT) {
|
||||
val->intval = 0;
|
||||
return 0;
|
||||
}
|
||||
return ret;
|
||||
}
|
||||
|
||||
if (psp == POWER_SUPPLY_PROP_PRESENT)
|
||||
val->intval = 1; /* battery present */
|
||||
else { /* POWER_SUPPLY_PROP_HEALTH */
|
||||
if (sbs_bat_needs_calibration(client)) {
|
||||
val->intval = POWER_SUPPLY_HEALTH_CALIBRATION_REQUIRED;
|
||||
} else {
|
||||
/* SBS spec doesn't have a general health command. */
|
||||
val->intval = POWER_SUPPLY_HEALTH_UNKNOWN;
|
||||
}
|
||||
}
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
static int sbs_get_battery_property(struct i2c_client *client,
|
||||
int reg_offset, enum power_supply_property psp,
|
||||
union power_supply_propval *val)
|
||||
@ -864,12 +868,7 @@ static int sbs_get_property(struct power_supply *psy,
|
||||
switch (psp) {
|
||||
case POWER_SUPPLY_PROP_PRESENT:
|
||||
case POWER_SUPPLY_PROP_HEALTH:
|
||||
if (chip->flags & SBS_FLAGS_TI_BQ20ZX5)
|
||||
ret = sbs_get_ti_battery_presence_and_health(client,
|
||||
psp, val);
|
||||
else
|
||||
ret = sbs_get_battery_presence_and_health(client, psp,
|
||||
val);
|
||||
ret = sbs_get_battery_presence_and_health(client, psp, val);
|
||||
|
||||