forked from Minki/linux
ds2760_battery: handle full_active_uAh == 0 case correctly
In systems where the battery monitor is not part of the battery pack and is hence not bootstrapped with sane values, the full_active_uAh is likely to be zero. Handle that case by defaulting to the rated_capacity information which can be passed to the driver using the new module parameter. Signed-off-by: Daniel Mack <daniel@caiaq.de> Cc: Szabolcs Gyurko <szabolcs.gyurko@tlt.hu> Acked-by: Matt Reimer <mreimer@vpop.net> Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This commit is contained in:
parent
c1e72193ea
commit
25f2bfa62a
@ -172,8 +172,13 @@ static int ds2760_battery_read_status(struct ds2760_device_info *di)
|
||||
di->full_active_uAh = di->raw[DS2760_ACTIVE_FULL] << 8 |
|
||||
di->raw[DS2760_ACTIVE_FULL + 1];
|
||||
|
||||
scale[0] = di->raw[DS2760_ACTIVE_FULL] << 8 |
|
||||
di->raw[DS2760_ACTIVE_FULL + 1];
|
||||
/* If the full_active_uAh value is not given, fall back to the rated
|
||||
* capacity. This is likely to happen when chips are not part of the
|
||||
* battery pack and is therefore not bootstrapped. */
|
||||
if (di->full_active_uAh == 0)
|
||||
di->full_active_uAh = di->rated_capacity / 1000L;
|
||||
|
||||
scale[0] = di->full_active_uAh;
|
||||
for (i = 1; i < 5; i++)
|
||||
scale[i] = scale[i - 1] + di->raw[DS2760_ACTIVE_FULL + 2 + i];
|
||||
|
||||
|