ds2760_battery: handle full_active_uAh == 0 case correctly

In systems where the battery monitor is not part of the battery pack and
is hence not bootstrapped with sane values, the full_active_uAh is
likely to be zero.

Handle that case by defaulting to the rated_capacity information which
can be passed to the driver using the new module parameter.

Signed-off-by: Daniel Mack <daniel@caiaq.de>
Cc: Szabolcs Gyurko <szabolcs.gyurko@tlt.hu>
Acked-by: Matt Reimer <mreimer@vpop.net>
Signed-off-by: Anton Vorontsov <cbouatmailru@gmail.com>
This commit is contained in:
Daniel Mack 2009-07-15 18:20:41 +02:00 committed by Anton Vorontsov
parent c1e72193ea
commit 25f2bfa62a

View File

@ -172,8 +172,13 @@ static int ds2760_battery_read_status(struct ds2760_device_info *di)
di->full_active_uAh = di->raw[DS2760_ACTIVE_FULL] << 8 |
di->raw[DS2760_ACTIVE_FULL + 1];
scale[0] = di->raw[DS2760_ACTIVE_FULL] << 8 |
di->raw[DS2760_ACTIVE_FULL + 1];
/* If the full_active_uAh value is not given, fall back to the rated
* capacity. This is likely to happen when chips are not part of the
* battery pack and is therefore not bootstrapped. */
if (di->full_active_uAh == 0)
di->full_active_uAh = di->rated_capacity / 1000L;
scale[0] = di->full_active_uAh;
for (i = 1; i < 5; i++)
scale[i] = scale[i - 1] + di->raw[DS2760_ACTIVE_FULL + 2 + i];