powerpc/numa: Avoid possible reference beyond prop. length in find_min_common_depth()
find_min_common_depth() was checking the property length incorrectly. The value is in bytes not cells, and it is using the second entry. Signed-off-By: Milton Miller <miltonm@bga.com> Signed-off-by: Benjamin Herrenschmidt <benh@kernel.crashing.org>
This commit is contained in:
		
							parent
							
								
									6a4d7a90fc
								
							
						
					
					
						commit
						20fcefe5a0
					
				| @ -289,7 +289,7 @@ static int __init find_min_common_depth(void) | ||||
| 	ref_points = of_get_property(rtas_root, | ||||
| 			"ibm,associativity-reference-points", &len); | ||||
| 
 | ||||
| 	if ((len >= 1) && ref_points) { | ||||
| 	if ((len >= 2 * sizeof(unsigned int)) && ref_points) { | ||||
| 		depth = ref_points[1]; | ||||
| 	} else { | ||||
| 		dbg("NUMA: ibm,associativity-reference-points not found.\n"); | ||||
|  | ||||
		Loading…
	