iio: chemical: bme680: Remove field value defines
Remove BME680_RUN_GAS_EN_BIT and BME680_NB_CONV_0_VAL field value definitions because the fields are simply boolean and integer respectively. Signed-off-by: David Frey <dpfrey@gmail.com> Reviewed-by: Himanshu Jha <himanshujha199640@gmail.com> Tested-by: Himanshu Jha <himanshujha199640@gmail.com> Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
8109b2c94f
commit
1691d4ca70
@ -54,8 +54,6 @@
|
||||
#define BME680_REG_CTRL_GAS_1 0x71
|
||||
#define BME680_RUN_GAS_MASK BIT(4)
|
||||
#define BME680_NB_CONV_MASK GENMASK(3, 0)
|
||||
#define BME680_RUN_GAS_EN_BIT BIT(4)
|
||||
#define BME680_NB_CONV_0_VAL 0
|
||||
|
||||
#define BME680_REG_MEAS_STAT_0 0x1D
|
||||
#define BME680_GAS_MEAS_BIT BIT(6)
|
||||
|
@ -572,10 +572,11 @@ static int bme680_gas_config(struct bme680_data *data)
|
||||
return ret;
|
||||
}
|
||||
|
||||
/* Selecting the runGas and NB conversion settings for the sensor */
|
||||
/* Enable the gas sensor and select heater profile set-point 0 */
|
||||
ret = regmap_update_bits(data->regmap, BME680_REG_CTRL_GAS_1,
|
||||
BME680_RUN_GAS_MASK | BME680_NB_CONV_MASK,
|
||||
BME680_RUN_GAS_EN_BIT | BME680_NB_CONV_0_VAL);
|
||||
FIELD_PREP(BME680_RUN_GAS_MASK, 1) |
|
||||
FIELD_PREP(BME680_NB_CONV_MASK, 0));
|
||||
if (ret < 0)
|
||||
dev_err(dev, "failed to write ctrl_gas_1 register\n");
|
||||
|
||||
|