forked from Minki/linux
docs: iio: add documentation for BNO055 driver
The bno055 driver is rather complex and have some oddities and not-obvious things that worth to document (e.g. calibration files). This patch also contains this [0] fix squashed in. [0] https://lore.kernel.org/lkml/20220704034041.15448-1-bagasdotme@gmail.com/ Signed-off-by: Andrea Merello <andrea.merello@iit.it> Reviewed-by: Andy Shevchenko <andy.shevchenko@gmail.com> Link: https://lore.kernel.org/r/20220907132205.28021-15-andrea.merello@iit.it Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
parent
50fe984f37
commit
130476acfd
51
Documentation/iio/bno055.rst
Normal file
51
Documentation/iio/bno055.rst
Normal file
@ -0,0 +1,51 @@
|
||||
.. SPDX-License-Identifier: GPL-2.0
|
||||
|
||||
==============================
|
||||
BNO055 driver
|
||||
==============================
|
||||
|
||||
1. Overview
|
||||
===========
|
||||
|
||||
This driver supports Bosch BNO055 IMUs (on both serial and I2C busses).
|
||||
|
||||
Accelerometer, magnetometer and gyroscope measures are always provided.
|
||||
When "fusion_enable" sysfs attribute is set to 1, orientation (both Euler
|
||||
angles and quaternion), linear velocity and gravity vector are also
|
||||
provided, but some sensor settings (e.g. low pass filtering and range)
|
||||
became locked (the IMU firmware controls them).
|
||||
|
||||
This driver supports also IIO buffers.
|
||||
|
||||
2. Calibration
|
||||
==============
|
||||
|
||||
The IMU continuously performs an autocalibration procedure if (and only if)
|
||||
operating in fusion mode. The magnetometer autocalibration can however be
|
||||
disabled writing 0 in the sysfs in_magn_calibration_fast_enable attribute.
|
||||
|
||||
The driver provides access to autocalibration flags (i.e. you can known if
|
||||
the IMU has successfully autocalibrated) and to the calibration data blob.
|
||||
|
||||
The user can save this blob in a firmware file (i.e. in /lib/firmware) that
|
||||
the driver looks for at probe time. If found, then the IMU is initialized
|
||||
with this calibration data. This saves the user from performing the
|
||||
calibration procedure every time (which consist of moving the IMU in
|
||||
various way).
|
||||
|
||||
The driver looks for calibration data file using two different names: first
|
||||
a file whose name is suffixed with the IMU unique ID (exposed in sysfs as
|
||||
serial_number) is searched for; this is useful when there is more than one
|
||||
IMU instance. If this file is not found, then a "generic" calibration file
|
||||
is searched for (which can be used when only one IMU is present, without
|
||||
struggling with fancy names, that change on each device).
|
||||
|
||||
Valid calibration file names would be e.g.
|
||||
bno055-caldata-0e7c26a33541515120204a35342b04ff.dat
|
||||
bno055-caldata.dat
|
||||
|
||||
In non-fusion mode the IIO 'offset' attributes provide access to the
|
||||
offsets from calibration data (if any), so that the user can apply them to
|
||||
the accel, angvel and magn IIO attributes. In fusion mode they are not
|
||||
needed (the IMU firmware internally applies those corrections) and they
|
||||
read as zero.
|
@ -10,3 +10,5 @@ Industrial I/O
|
||||