2008-01-17 07:51:08 +00:00
|
|
|
#
|
|
|
|
# Generic thermal sysfs drivers configuration
|
|
|
|
#
|
|
|
|
|
|
|
|
menuconfig THERMAL
|
2008-04-21 08:07:13 +00:00
|
|
|
tristate "Generic Thermal sysfs driver"
|
2008-01-17 07:51:08 +00:00
|
|
|
help
|
|
|
|
Generic Thermal Sysfs driver offers a generic mechanism for
|
|
|
|
thermal management. Usually it's made up of one or more thermal
|
|
|
|
zone and cooling device.
|
2008-02-07 21:55:08 +00:00
|
|
|
Each thermal zone contains its own temperature, trip points,
|
2008-01-17 07:51:08 +00:00
|
|
|
cooling devices.
|
|
|
|
All platforms with ACPI thermal support can use this driver.
|
2008-04-21 08:07:13 +00:00
|
|
|
If you want this support, you should say Y or M here.
|
2008-06-24 17:38:56 +00:00
|
|
|
|
2012-11-15 01:16:20 +00:00
|
|
|
if THERMAL
|
|
|
|
|
2008-06-24 17:38:56 +00:00
|
|
|
config THERMAL_HWMON
|
2011-07-28 20:48:40 +00:00
|
|
|
bool
|
2013-07-03 19:14:28 +00:00
|
|
|
prompt "Expose thermal sensors as hwmon device"
|
2008-06-24 17:38:56 +00:00
|
|
|
depends on HWMON=y || HWMON=THERMAL
|
2011-07-28 20:48:40 +00:00
|
|
|
default y
|
2013-07-03 19:14:28 +00:00
|
|
|
help
|
|
|
|
In case a sensor is registered with the thermal
|
|
|
|
framework, this option will also register it
|
|
|
|
as a hwmon. The sensor will then have the common
|
|
|
|
hwmon sysfs interface.
|
|
|
|
|
|
|
|
Say 'Y' here if you want all thermal sensors to
|
|
|
|
have hwmon sysfs interface too.
|
2012-03-21 19:55:03 +00:00
|
|
|
|
2013-07-03 19:35:39 +00:00
|
|
|
config THERMAL_OF
|
|
|
|
bool
|
|
|
|
prompt "APIs to parse thermal data out of device tree"
|
|
|
|
depends on OF
|
|
|
|
default y
|
|
|
|
help
|
|
|
|
This options provides helpers to add the support to
|
|
|
|
read and parse thermal data definitions out of the
|
|
|
|
device tree blob.
|
|
|
|
|
|
|
|
Say 'Y' here if you need to build thermal infrastructure
|
|
|
|
based on device tree.
|
|
|
|
|
2015-03-03 10:43:03 +00:00
|
|
|
config THERMAL_WRITABLE_TRIPS
|
|
|
|
bool "Enable writable trip points"
|
|
|
|
help
|
|
|
|
This option allows the system integrator to choose whether
|
|
|
|
trip temperatures can be changed from userspace. The
|
|
|
|
writable trips need to be specified when setting up the
|
|
|
|
thermal zone but the choice here takes precedence.
|
|
|
|
|
|
|
|
Say 'Y' here if you would like to allow userspace tools to
|
|
|
|
change trip temperatures.
|
|
|
|
|
2012-11-15 01:16:20 +00:00
|
|
|
choice
|
|
|
|
prompt "Default Thermal governor"
|
|
|
|
default THERMAL_DEFAULT_GOV_STEP_WISE
|
|
|
|
help
|
|
|
|
This option sets which thermal governor shall be loaded at
|
|
|
|
startup. If in doubt, select 'step_wise'.
|
|
|
|
|
|
|
|
config THERMAL_DEFAULT_GOV_STEP_WISE
|
|
|
|
bool "step_wise"
|
2013-02-08 12:33:42 +00:00
|
|
|
select THERMAL_GOV_STEP_WISE
|
2012-11-15 01:16:20 +00:00
|
|
|
help
|
|
|
|
Use the step_wise governor as default. This throttles the
|
|
|
|
devices one step at a time.
|
|
|
|
|
|
|
|
config THERMAL_DEFAULT_GOV_FAIR_SHARE
|
|
|
|
bool "fair_share"
|
2013-02-08 12:33:42 +00:00
|
|
|
select THERMAL_GOV_FAIR_SHARE
|
2012-11-15 01:16:20 +00:00
|
|
|
help
|
|
|
|
Use the fair_share governor as default. This throttles the
|
|
|
|
devices based on their 'contribution' to a zone. The
|
|
|
|
contribution should be provided through platform data.
|
|
|
|
|
|
|
|
config THERMAL_DEFAULT_GOV_USER_SPACE
|
|
|
|
bool "user_space"
|
2013-02-08 12:33:42 +00:00
|
|
|
select THERMAL_GOV_USER_SPACE
|
2012-11-15 01:16:20 +00:00
|
|
|
help
|
|
|
|
Select this if you want to let the user space manage the
|
2013-09-08 21:58:53 +00:00
|
|
|
platform thermals.
|
2012-11-15 01:16:20 +00:00
|
|
|
|
2015-03-02 17:17:19 +00:00
|
|
|
config THERMAL_DEFAULT_GOV_POWER_ALLOCATOR
|
|
|
|
bool "power_allocator"
|
|
|
|
select THERMAL_GOV_POWER_ALLOCATOR
|
|
|
|
help
|
|
|
|
Select this if you want to control temperature based on
|
|
|
|
system and device power allocation. This governor can only
|
|
|
|
operate on cooling devices that implement the power API.
|
|
|
|
|
2012-11-15 01:16:20 +00:00
|
|
|
endchoice
|
|
|
|
|
2013-02-08 12:33:42 +00:00
|
|
|
config THERMAL_GOV_FAIR_SHARE
|
2012-11-15 01:16:20 +00:00
|
|
|
bool "Fair-share thermal governor"
|
|
|
|
help
|
|
|
|
Enable this to manage platform thermals using fair-share governor.
|
|
|
|
|
2013-02-08 12:33:42 +00:00
|
|
|
config THERMAL_GOV_STEP_WISE
|
2012-11-15 01:16:20 +00:00
|
|
|
bool "Step_wise thermal governor"
|
|
|
|
help
|
|
|
|
Enable this to manage platform thermals using a simple linear
|
2013-09-27 18:20:33 +00:00
|
|
|
governor.
|
2012-11-15 01:16:20 +00:00
|
|
|
|
2014-07-22 15:37:13 +00:00
|
|
|
config THERMAL_GOV_BANG_BANG
|
|
|
|
bool "Bang Bang thermal governor"
|
|
|
|
default n
|
|
|
|
help
|
|
|
|
Enable this to manage platform thermals using bang bang governor.
|
|
|
|
|
|
|
|
Say 'Y' here if you want to use two point temperature regulation
|
|
|
|
used for fans without throttling. Some fan drivers depend on this
|
|
|
|
governor to be enabled (e.g. acerhdf).
|
|
|
|
|
2013-02-08 12:33:42 +00:00
|
|
|
config THERMAL_GOV_USER_SPACE
|
2012-11-15 01:16:20 +00:00
|
|
|
bool "User_space thermal governor"
|
|
|
|
help
|
|
|
|
Enable this to let the user space manage the platform thermals.
|
|
|
|
|
2015-03-02 17:17:19 +00:00
|
|
|
config THERMAL_GOV_POWER_ALLOCATOR
|
|
|
|
bool "Power allocator thermal governor"
|
|
|
|
help
|
|
|
|
Enable this to manage platform thermals by dynamically
|
|
|
|
allocating and limiting power to devices.
|
|
|
|
|
2012-08-16 11:41:40 +00:00
|
|
|
config CPU_THERMAL
|
2013-03-26 15:57:01 +00:00
|
|
|
bool "generic cpu cooling support"
|
2012-11-15 01:16:20 +00:00
|
|
|
depends on CPU_FREQ
|
2013-09-12 23:26:45 +00:00
|
|
|
depends on THERMAL_OF
|
2012-08-16 11:41:40 +00:00
|
|
|
help
|
|
|
|
This implements the generic cpu cooling mechanism through frequency
|
2013-04-17 17:12:10 +00:00
|
|
|
reduction. An ACPI version of this already exists
|
|
|
|
(drivers/acpi/processor_thermal.c).
|
2012-08-16 11:41:40 +00:00
|
|
|
This will be useful for platforms using the generic thermal interface
|
|
|
|
and not the ACPI interface.
|
2013-04-17 17:12:10 +00:00
|
|
|
|
2012-08-16 11:41:40 +00:00
|
|
|
If you want this support, you should say Y here.
|
|
|
|
|
2014-01-06 13:04:18 +00:00
|
|
|
config CLOCK_THERMAL
|
|
|
|
bool "Generic clock cooling support"
|
|
|
|
depends on COMMON_CLK
|
|
|
|
depends on PM_OPP
|
|
|
|
help
|
|
|
|
This entry implements the generic clock cooling mechanism through
|
|
|
|
frequency clipping. Typically used to cool off co-processors. The
|
|
|
|
device that is configured to use this cooling mechanism will be
|
|
|
|
controlled to reduce clock frequency whenever temperature is high.
|
|
|
|
|
|
|
|
If you want this support, you should say Y here.
|
|
|
|
|
2013-02-04 00:30:15 +00:00
|
|
|
config THERMAL_EMULATION
|
|
|
|
bool "Thermal emulation mode support"
|
|
|
|
help
|
|
|
|
Enable this option to make a emul_temp sysfs node in thermal zone
|
|
|
|
directory to support temperature emulation. With emulation sysfs node,
|
|
|
|
user can manually input temperature and test the different trip
|
|
|
|
threshold behaviour for simulation purpose.
|
|
|
|
|
2013-03-26 21:38:34 +00:00
|
|
|
WARNING: Be careful while enabling this option on production systems,
|
|
|
|
because userland can easily disable the thermal policy by simply
|
|
|
|
flooding this sysfs node with low temperature values.
|
|
|
|
|
2015-05-20 11:16:37 +00:00
|
|
|
config HISI_THERMAL
|
|
|
|
tristate "Hisilicon thermal driver"
|
|
|
|
depends on ARCH_HISI && CPU_THERMAL && OF
|
|
|
|
help
|
|
|
|
Enable this to plug hisilicon's thermal sensor driver into the Linux
|
|
|
|
thermal framework. cpufreq is used as the cooling device to throttle
|
|
|
|
CPUs when the passive trip is crossed.
|
|
|
|
|
2013-06-24 06:30:44 +00:00
|
|
|
config IMX_THERMAL
|
|
|
|
tristate "Temperature sensor driver for Freescale i.MX SoCs"
|
|
|
|
depends on CPU_THERMAL
|
|
|
|
depends on MFD_SYSCON
|
|
|
|
depends on OF
|
|
|
|
help
|
|
|
|
Support for Temperature Monitor (TEMPMON) found on Freescale i.MX SoCs.
|
|
|
|
It supports one critical trip point and one passive trip point. The
|
|
|
|
cpufreq is used as the cooling device to throttle CPUs when the
|
|
|
|
passive trip is crossed.
|
|
|
|
|
2012-03-21 19:55:03 +00:00
|
|
|
config SPEAR_THERMAL
|
|
|
|
bool "SPEAr thermal sensor driver"
|
|
|
|
depends on PLAT_SPEAR
|
2012-05-29 18:18:51 +00:00
|
|
|
depends on OF
|
2012-03-21 19:55:03 +00:00
|
|
|
help
|
|
|
|
Enable this to plug the SPEAr thermal sensor driver into the Linux
|
2013-09-27 18:20:33 +00:00
|
|
|
thermal framework.
|
2012-07-21 00:53:48 +00:00
|
|
|
|
2014-11-24 04:58:59 +00:00
|
|
|
config ROCKCHIP_THERMAL
|
|
|
|
tristate "Rockchip thermal driver"
|
|
|
|
depends on ARCH_ROCKCHIP
|
|
|
|
depends on RESET_CONTROLLER
|
|
|
|
help
|
|
|
|
Rockchip thermal driver provides support for Temperature sensor
|
|
|
|
ADC (TS-ADC) found on Rockchip SoCs. It supports one critical
|
|
|
|
trip point. Cpufreq is used as the cooling device and will throttle
|
|
|
|
CPUs when the Temperature crosses the passive trip point.
|
|
|
|
|
2012-07-21 00:53:48 +00:00
|
|
|
config RCAR_THERMAL
|
|
|
|
tristate "Renesas R-Car thermal driver"
|
2013-11-27 01:18:34 +00:00
|
|
|
depends on ARCH_SHMOBILE || COMPILE_TEST
|
2014-01-27 08:40:58 +00:00
|
|
|
depends on HAS_IOMEM
|
2012-07-21 00:53:48 +00:00
|
|
|
help
|
|
|
|
Enable this to plug the R-Car thermal sensor driver into the Linux
|
2013-09-27 18:20:33 +00:00
|
|
|
thermal framework.
|
2012-08-16 11:41:41 +00:00
|
|
|
|
2013-02-06 06:35:24 +00:00
|
|
|
config KIRKWOOD_THERMAL
|
|
|
|
tristate "Temperature sensor on Marvell Kirkwood SoCs"
|
2014-08-30 16:46:08 +00:00
|
|
|
depends on MACH_KIRKWOOD
|
2013-02-06 06:35:24 +00:00
|
|
|
depends on OF
|
|
|
|
help
|
|
|
|
Support for the Kirkwood thermal sensor driver into the Linux thermal
|
|
|
|
framework. Only kirkwood 88F6282 and 88F6283 have this sensor.
|
|
|
|
|
2013-02-06 06:35:26 +00:00
|
|
|
config DOVE_THERMAL
|
|
|
|
tristate "Temperature sensor on Marvell Dove SoCs"
|
2014-05-31 11:50:26 +00:00
|
|
|
depends on ARCH_DOVE || MACH_DOVE
|
2013-02-06 06:35:26 +00:00
|
|
|
depends on OF
|
|
|
|
help
|
|
|
|
Support for the Dove thermal sensor driver in the Linux thermal
|
|
|
|
framework.
|
|
|
|
|
2012-11-15 10:56:42 +00:00
|
|
|
config DB8500_THERMAL
|
|
|
|
bool "DB8500 thermal management"
|
|
|
|
depends on ARCH_U8500
|
|
|
|
default y
|
|
|
|
help
|
|
|
|
Adds DB8500 thermal management implementation according to the thermal
|
|
|
|
management framework. A thermal zone with several trip points will be
|
|
|
|
created. Cooling devices can be bound to the trip points to cool this
|
|
|
|
thermal zone if trip points reached.
|
|
|
|
|
2013-04-02 01:37:41 +00:00
|
|
|
config ARMADA_THERMAL
|
|
|
|
tristate "Armada 370/XP thermal management"
|
|
|
|
depends on ARCH_MVEBU
|
|
|
|
depends on OF
|
|
|
|
help
|
|
|
|
Enable this option if you want to have support for thermal management
|
|
|
|
controller present in Armada 370 and Armada XP SoC.
|
|
|
|
|
2014-09-29 14:17:31 +00:00
|
|
|
config TEGRA_SOCTHERM
|
|
|
|
tristate "Tegra SOCTHERM thermal management"
|
|
|
|
depends on ARCH_TEGRA
|
|
|
|
help
|
|
|
|
Enable this option for integrated thermal management support on NVIDIA
|
|
|
|
Tegra124 systems-on-chip. The driver supports four thermal zones
|
|
|
|
(CPU, GPU, MEM, PLLX). Cooling devices can be bound to the thermal
|
|
|
|
zones to manage temperatures. This option is also required for the
|
|
|
|
emergency thermal reset (thermtrip) feature to function.
|
|
|
|
|
2012-11-15 10:56:42 +00:00
|
|
|
config DB8500_CPUFREQ_COOLING
|
|
|
|
tristate "DB8500 cpufreq cooling"
|
|
|
|
depends on ARCH_U8500
|
|
|
|
depends on CPU_THERMAL
|
|
|
|
default y
|
|
|
|
help
|
|
|
|
Adds DB8500 cpufreq cooling devices, and these cooling devices can be
|
|
|
|
bound to thermal zone trip points. When a trip point reached, the
|
|
|
|
bound cpufreq cooling device turns active to set CPU frequency low to
|
|
|
|
cool down the CPU.
|
2012-09-21 09:02:24 +00:00
|
|
|
|
2013-01-21 12:37:57 +00:00
|
|
|
config INTEL_POWERCLAMP
|
|
|
|
tristate "Intel PowerClamp idle injection driver"
|
|
|
|
depends on THERMAL
|
|
|
|
depends on X86
|
|
|
|
depends on CPU_SUP_INTEL
|
|
|
|
help
|
|
|
|
Enable this to enable Intel PowerClamp idle injection driver. This
|
|
|
|
enforce idle time which results in more package C-state residency. The
|
|
|
|
user interface is exposed via generic thermal framework.
|
|
|
|
|
2013-05-17 23:42:02 +00:00
|
|
|
config X86_PKG_TEMP_THERMAL
|
|
|
|
tristate "X86 package temperature thermal driver"
|
2013-06-17 19:27:17 +00:00
|
|
|
depends on X86_THERMAL_VECTOR
|
2013-05-17 23:42:02 +00:00
|
|
|
select THERMAL_GOV_USER_SPACE
|
|
|
|
default m
|
|
|
|
help
|
|
|
|
Enable this to register CPU digital sensor for package temperature as
|
|
|
|
thermal zone. Each package will have its own thermal zone. There are
|
|
|
|
two trip points which can be set by user to get notifications via thermal
|
|
|
|
notification methods.
|
|
|
|
|
2015-03-02 21:12:58 +00:00
|
|
|
config INTEL_SOC_DTS_IOSF_CORE
|
|
|
|
tristate
|
|
|
|
depends on X86
|
|
|
|
select IOSF_MBI
|
|
|
|
help
|
|
|
|
This is becoming a common feature for Intel SoCs to expose the additional
|
|
|
|
digital temperature sensors (DTSs) using side band interface (IOSF). This
|
|
|
|
implements the common set of helper functions to register, get temperature
|
|
|
|
and get/set thresholds on DTSs.
|
|
|
|
|
2014-04-07 20:57:15 +00:00
|
|
|
config INTEL_SOC_DTS_THERMAL
|
|
|
|
tristate "Intel SoCs DTS thermal driver"
|
2015-03-02 21:12:59 +00:00
|
|
|
depends on X86
|
|
|
|
select INTEL_SOC_DTS_IOSF_CORE
|
2014-04-07 20:57:15 +00:00
|
|
|
help
|
|
|
|
Enable this to register Intel SoCs (e.g. Bay Trail) platform digital
|
|
|
|
temperature sensor (DTS). These SoCs have two additional DTSs in
|
|
|
|
addition to DTSs on CPU cores. Each DTS will be registered as a
|
|
|
|
thermal zone. There are two trip points. One of the trip point can
|
|
|
|
be set by user mode programs to get notifications via Linux thermal
|
|
|
|
notification methods.The other trip is a critical trip point, which
|
|
|
|
was set by the driver based on the TJ MAX temperature.
|
|
|
|
|
2015-04-15 02:08:15 +00:00
|
|
|
config INTEL_QUARK_DTS_THERMAL
|
|
|
|
tristate "Intel Quark DTS thermal driver"
|
|
|
|
depends on X86_INTEL_QUARK
|
|
|
|
help
|
|
|
|
Enable this to register Intel Quark SoC (e.g. X1000) platform digital
|
|
|
|
temperature sensor (DTS). For X1000 SoC, it has one on-die DTS.
|
|
|
|
The DTS will be registered as a thermal zone. There are two trip points:
|
|
|
|
hot & critical. The critical trip point default value is set by
|
|
|
|
underlying BIOS/Firmware.
|
|
|
|
|
2014-03-13 16:34:05 +00:00
|
|
|
config INT340X_THERMAL
|
2014-03-14 04:45:05 +00:00
|
|
|
tristate "ACPI INT340X thermal drivers"
|
2014-03-13 16:34:05 +00:00
|
|
|
depends on X86 && ACPI
|
2014-03-23 15:37:32 +00:00
|
|
|
select THERMAL_GOV_USER_SPACE
|
2014-09-03 07:14:23 +00:00
|
|
|
select ACPI_THERMAL_REL
|
2014-06-19 07:43:29 +00:00
|
|
|
select ACPI_FAN
|
2015-03-02 21:13:00 +00:00
|
|
|
select INTEL_SOC_DTS_IOSF_CORE
|
2014-03-13 16:34:05 +00:00
|
|
|
help
|
|
|
|
Newer laptops and tablets that use ACPI may have thermal sensors and
|
|
|
|
other devices with thermal control capabilities outside the core
|
|
|
|
CPU/SOC, for thermal safety reasons.
|
|
|
|
They are exposed for the OS to use via the INT3400 ACPI device object
|
|
|
|
as the master, and INT3401~INT340B ACPI device objects as the slaves.
|
|
|
|
Enable this to expose the temperature information and cooling ability
|
|
|
|
from these objects to userspace via the normal thermal framework.
|
|
|
|
This means that a wide range of applications and GUI widgets can show
|
|
|
|
the information to the user or use this information for making
|
|
|
|
decisions. For example, the Intel Thermal Daemon can use this
|
|
|
|
information to allow the user to select his laptop to run without
|
|
|
|
turning on the fans.
|
|
|
|
|
2014-09-03 07:14:23 +00:00
|
|
|
config ACPI_THERMAL_REL
|
|
|
|
tristate
|
|
|
|
depends on ACPI
|
|
|
|
|
2015-06-10 20:34:24 +00:00
|
|
|
config INTEL_PCH_THERMAL
|
|
|
|
tristate "Intel PCH Thermal Reporting Driver"
|
|
|
|
depends on X86 && PCI
|
|
|
|
help
|
|
|
|
Enable this to support thermal reporting on certain intel PCHs.
|
|
|
|
Thermal reporting device will provide temperature reading,
|
|
|
|
programmable trip points and other information.
|
|
|
|
|
2013-05-15 15:46:00 +00:00
|
|
|
menu "Texas Instruments thermal drivers"
|
|
|
|
source "drivers/thermal/ti-soc-thermal/Kconfig"
|
|
|
|
endmenu
|
2013-06-17 22:31:26 +00:00
|
|
|
|
2013-06-24 10:50:22 +00:00
|
|
|
menu "Samsung thermal drivers"
|
2013-10-04 12:36:42 +00:00
|
|
|
depends on ARCH_EXYNOS
|
2013-06-24 10:50:22 +00:00
|
|
|
source "drivers/thermal/samsung/Kconfig"
|
|
|
|
endmenu
|
|
|
|
|
2014-06-05 15:06:55 +00:00
|
|
|
menu "STMicroelectronics thermal drivers"
|
|
|
|
depends on ARCH_STI && OF
|
|
|
|
source "drivers/thermal/st/Kconfig"
|
|
|
|
endmenu
|
|
|
|
|
2015-02-05 17:12:56 +00:00
|
|
|
config QCOM_SPMI_TEMP_ALARM
|
|
|
|
tristate "Qualcomm SPMI PMIC Temperature Alarm"
|
|
|
|
depends on OF && SPMI && IIO
|
|
|
|
select REGMAP_SPMI
|
|
|
|
help
|
|
|
|
This enables a thermal sysfs driver for Qualcomm plug-and-play (QPNP)
|
|
|
|
PMIC devices. It shows up in sysfs as a thermal sensor with multiple
|
|
|
|
trip points. The temperature reported by the thermal sensor reflects the
|
|
|
|
real time die temperature if an ADC is present or an estimate of the
|
|
|
|
temperature based upon the over temperature stage value.
|
|
|
|
|
2012-11-15 01:16:20 +00:00
|
|
|
endif
|