2015-11-24 11:37:35 +00:00
|
|
|
/*
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
* Copyright (C) 2014-2017 Linaro Ltd. <ard.biesheuvel@linaro.org>
|
2015-11-24 11:37:35 +00:00
|
|
|
*
|
|
|
|
* This program is free software; you can redistribute it and/or modify
|
|
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
|
|
* published by the Free Software Foundation.
|
|
|
|
*/
|
|
|
|
|
|
|
|
#include <linux/elf.h>
|
|
|
|
#include <linux/kernel.h>
|
|
|
|
#include <linux/module.h>
|
|
|
|
#include <linux/sort.h>
|
|
|
|
|
2018-11-22 08:46:46 +00:00
|
|
|
static struct plt_entry __get_adrp_add_pair(u64 dst, u64 pc,
|
|
|
|
enum aarch64_insn_register reg)
|
|
|
|
{
|
|
|
|
u32 adrp, add;
|
|
|
|
|
|
|
|
adrp = aarch64_insn_gen_adr(pc, dst, reg, AARCH64_INSN_ADR_TYPE_ADRP);
|
|
|
|
add = aarch64_insn_gen_add_sub_imm(reg, reg, dst % SZ_4K,
|
|
|
|
AARCH64_INSN_VARIANT_64BIT,
|
|
|
|
AARCH64_INSN_ADSB_ADD);
|
|
|
|
|
|
|
|
return (struct plt_entry){ cpu_to_le32(adrp), cpu_to_le32(add) };
|
|
|
|
}
|
|
|
|
|
|
|
|
struct plt_entry get_plt_entry(u64 dst, void *pc)
|
|
|
|
{
|
|
|
|
struct plt_entry plt;
|
|
|
|
static u32 br;
|
|
|
|
|
|
|
|
if (!br)
|
|
|
|
br = aarch64_insn_gen_branch_reg(AARCH64_INSN_REG_16,
|
|
|
|
AARCH64_INSN_BRANCH_NOLINK);
|
|
|
|
|
|
|
|
plt = __get_adrp_add_pair(dst, (u64)pc, AARCH64_INSN_REG_16);
|
|
|
|
plt.br = cpu_to_le32(br);
|
|
|
|
|
|
|
|
return plt;
|
|
|
|
}
|
|
|
|
|
|
|
|
bool plt_entries_equal(const struct plt_entry *a, const struct plt_entry *b)
|
|
|
|
{
|
|
|
|
u64 p, q;
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Check whether both entries refer to the same target:
|
|
|
|
* do the cheapest checks first.
|
|
|
|
* If the 'add' or 'br' opcodes are different, then the target
|
|
|
|
* cannot be the same.
|
|
|
|
*/
|
|
|
|
if (a->add != b->add || a->br != b->br)
|
|
|
|
return false;
|
|
|
|
|
|
|
|
p = ALIGN_DOWN((u64)a, SZ_4K);
|
|
|
|
q = ALIGN_DOWN((u64)b, SZ_4K);
|
|
|
|
|
|
|
|
/*
|
|
|
|
* If the 'adrp' opcodes are the same then we just need to check
|
|
|
|
* that they refer to the same 4k region.
|
|
|
|
*/
|
|
|
|
if (a->adrp == b->adrp && p == q)
|
|
|
|
return true;
|
|
|
|
|
|
|
|
return (p + aarch64_insn_adrp_get_offset(le32_to_cpu(a->adrp))) ==
|
|
|
|
(q + aarch64_insn_adrp_get_offset(le32_to_cpu(b->adrp)));
|
|
|
|
}
|
|
|
|
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
static bool in_init(const struct module *mod, void *loc)
|
|
|
|
{
|
|
|
|
return (u64)loc - (u64)mod->init_layout.base < mod->init_layout.size;
|
|
|
|
}
|
|
|
|
|
2018-11-05 18:53:23 +00:00
|
|
|
u64 module_emit_plt_entry(struct module *mod, Elf64_Shdr *sechdrs,
|
|
|
|
void *loc, const Elf64_Rela *rela,
|
2015-11-24 11:37:35 +00:00
|
|
|
Elf64_Sym *sym)
|
|
|
|
{
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
struct mod_plt_sec *pltsec = !in_init(mod, loc) ? &mod->arch.core :
|
|
|
|
&mod->arch.init;
|
2018-11-05 18:53:23 +00:00
|
|
|
struct plt_entry *plt = (struct plt_entry *)sechdrs[pltsec->plt_shndx].sh_addr;
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
int i = pltsec->plt_num_entries;
|
2018-11-22 08:46:46 +00:00
|
|
|
int j = i - 1;
|
2015-11-24 11:37:35 +00:00
|
|
|
u64 val = sym->st_value + rela->r_addend;
|
|
|
|
|
2018-11-22 08:46:46 +00:00
|
|
|
if (is_forbidden_offset_for_adrp(&plt[i].adrp))
|
|
|
|
i++;
|
|
|
|
|
|
|
|
plt[i] = get_plt_entry(val, &plt[i]);
|
2015-11-24 11:37:35 +00:00
|
|
|
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
/*
|
|
|
|
* Check if the entry we just created is a duplicate. Given that the
|
|
|
|
* relocations are sorted, this will be the last entry we allocated.
|
|
|
|
* (if one exists).
|
|
|
|
*/
|
2018-11-22 08:46:46 +00:00
|
|
|
if (j >= 0 && plt_entries_equal(plt + i, plt + j))
|
|
|
|
return (u64)&plt[j];
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
|
2018-11-22 08:46:46 +00:00
|
|
|
pltsec->plt_num_entries += i - j;
|
2018-03-06 17:15:31 +00:00
|
|
|
if (WARN_ON(pltsec->plt_num_entries > pltsec->plt_max_entries))
|
|
|
|
return 0;
|
2015-11-24 11:37:35 +00:00
|
|
|
|
|
|
|
return (u64)&plt[i];
|
|
|
|
}
|
|
|
|
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
#ifdef CONFIG_ARM64_ERRATUM_843419
|
2018-11-05 18:53:23 +00:00
|
|
|
u64 module_emit_veneer_for_adrp(struct module *mod, Elf64_Shdr *sechdrs,
|
|
|
|
void *loc, u64 val)
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
{
|
|
|
|
struct mod_plt_sec *pltsec = !in_init(mod, loc) ? &mod->arch.core :
|
|
|
|
&mod->arch.init;
|
2018-11-05 18:53:23 +00:00
|
|
|
struct plt_entry *plt = (struct plt_entry *)sechdrs[pltsec->plt_shndx].sh_addr;
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
int i = pltsec->plt_num_entries++;
|
2018-11-22 08:46:46 +00:00
|
|
|
u32 br;
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
int rd;
|
|
|
|
|
|
|
|
if (WARN_ON(pltsec->plt_num_entries > pltsec->plt_max_entries))
|
|
|
|
return 0;
|
|
|
|
|
2018-11-22 08:46:46 +00:00
|
|
|
if (is_forbidden_offset_for_adrp(&plt[i].adrp))
|
|
|
|
i = pltsec->plt_num_entries++;
|
|
|
|
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
/* get the destination register of the ADRP instruction */
|
|
|
|
rd = aarch64_insn_decode_register(AARCH64_INSN_REGTYPE_RD,
|
|
|
|
le32_to_cpup((__le32 *)loc));
|
|
|
|
|
|
|
|
br = aarch64_insn_gen_branch_imm((u64)&plt[i].br, (u64)loc + 4,
|
|
|
|
AARCH64_INSN_BRANCH_NOLINK);
|
|
|
|
|
2018-11-22 08:46:46 +00:00
|
|
|
plt[i] = __get_adrp_add_pair(val, (u64)&plt[i], rd);
|
|
|
|
plt[i].br = cpu_to_le32(br);
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
|
|
|
|
return (u64)&plt[i];
|
|
|
|
}
|
|
|
|
#endif
|
|
|
|
|
2015-11-24 11:37:35 +00:00
|
|
|
#define cmp_3way(a,b) ((a) < (b) ? -1 : (a) > (b))
|
|
|
|
|
|
|
|
static int cmp_rela(const void *a, const void *b)
|
|
|
|
{
|
|
|
|
const Elf64_Rela *x = a, *y = b;
|
|
|
|
int i;
|
|
|
|
|
|
|
|
/* sort by type, symbol index and addend */
|
|
|
|
i = cmp_3way(ELF64_R_TYPE(x->r_info), ELF64_R_TYPE(y->r_info));
|
|
|
|
if (i == 0)
|
|
|
|
i = cmp_3way(ELF64_R_SYM(x->r_info), ELF64_R_SYM(y->r_info));
|
|
|
|
if (i == 0)
|
|
|
|
i = cmp_3way(x->r_addend, y->r_addend);
|
|
|
|
return i;
|
|
|
|
}
|
|
|
|
|
|
|
|
static bool duplicate_rel(const Elf64_Rela *rela, int num)
|
|
|
|
{
|
|
|
|
/*
|
|
|
|
* Entries are sorted by type, symbol index and addend. That means
|
|
|
|
* that, if a duplicate entry exists, it must be in the preceding
|
|
|
|
* slot.
|
|
|
|
*/
|
|
|
|
return num > 0 && cmp_rela(rela + num, rela + num - 1) == 0;
|
|
|
|
}
|
|
|
|
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
static unsigned int count_plts(Elf64_Sym *syms, Elf64_Rela *rela, int num,
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
Elf64_Word dstidx, Elf_Shdr *dstsec)
|
2015-11-24 11:37:35 +00:00
|
|
|
{
|
|
|
|
unsigned int ret = 0;
|
|
|
|
Elf64_Sym *s;
|
|
|
|
int i;
|
|
|
|
|
|
|
|
for (i = 0; i < num; i++) {
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
u64 min_align;
|
|
|
|
|
2015-11-24 11:37:35 +00:00
|
|
|
switch (ELF64_R_TYPE(rela[i].r_info)) {
|
|
|
|
case R_AARCH64_JUMP26:
|
|
|
|
case R_AARCH64_CALL26:
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
if (!IS_ENABLED(CONFIG_RANDOMIZE_BASE))
|
|
|
|
break;
|
|
|
|
|
2015-11-24 11:37:35 +00:00
|
|
|
/*
|
|
|
|
* We only have to consider branch targets that resolve
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
* to symbols that are defined in a different section.
|
|
|
|
* This is not simply a heuristic, it is a fundamental
|
|
|
|
* limitation, since there is no guaranteed way to emit
|
|
|
|
* PLT entries sufficiently close to the branch if the
|
|
|
|
* section size exceeds the range of a branch
|
|
|
|
* instruction. So ignore relocations against defined
|
|
|
|
* symbols if they live in the same section as the
|
|
|
|
* relocation target.
|
2015-11-24 11:37:35 +00:00
|
|
|
*/
|
|
|
|
s = syms + ELF64_R_SYM(rela[i].r_info);
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
if (s->st_shndx == dstidx)
|
2015-11-24 11:37:35 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Jump relocations with non-zero addends against
|
|
|
|
* undefined symbols are supported by the ELF spec, but
|
|
|
|
* do not occur in practice (e.g., 'jump n bytes past
|
|
|
|
* the entry point of undefined function symbol f').
|
|
|
|
* So we need to support them, but there is no need to
|
|
|
|
* take them into consideration when trying to optimize
|
|
|
|
* this code. So let's only check for duplicates when
|
|
|
|
* the addend is zero: this allows us to record the PLT
|
|
|
|
* entry address in the symbol table itself, rather than
|
|
|
|
* having to search the list for duplicates each time we
|
|
|
|
* emit one.
|
|
|
|
*/
|
|
|
|
if (rela[i].r_addend != 0 || !duplicate_rel(rela, i))
|
|
|
|
ret++;
|
|
|
|
break;
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
case R_AARCH64_ADR_PREL_PG_HI21_NC:
|
|
|
|
case R_AARCH64_ADR_PREL_PG_HI21:
|
2018-03-06 17:15:35 +00:00
|
|
|
if (!IS_ENABLED(CONFIG_ARM64_ERRATUM_843419) ||
|
|
|
|
!cpus_have_const_cap(ARM64_WORKAROUND_843419))
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
break;
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Determine the minimal safe alignment for this ADRP
|
|
|
|
* instruction: the section alignment at which it is
|
|
|
|
* guaranteed not to appear at a vulnerable offset.
|
|
|
|
*
|
|
|
|
* This comes down to finding the least significant zero
|
|
|
|
* bit in bits [11:3] of the section offset, and
|
|
|
|
* increasing the section's alignment so that the
|
|
|
|
* resulting address of this instruction is guaranteed
|
|
|
|
* to equal the offset in that particular bit (as well
|
|
|
|
* as all less signficant bits). This ensures that the
|
|
|
|
* address modulo 4 KB != 0xfff8 or 0xfffc (which would
|
|
|
|
* have all ones in bits [11:3])
|
|
|
|
*/
|
|
|
|
min_align = 2ULL << ffz(rela[i].r_offset | 0x7);
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Allocate veneer space for each ADRP that may appear
|
|
|
|
* at a vulnerable offset nonetheless. At relocation
|
|
|
|
* time, some of these will remain unused since some
|
|
|
|
* ADRP instructions can be patched to ADR instructions
|
|
|
|
* instead.
|
|
|
|
*/
|
|
|
|
if (min_align > SZ_4K)
|
|
|
|
ret++;
|
|
|
|
else
|
|
|
|
dstsec->sh_addralign = max(dstsec->sh_addralign,
|
|
|
|
min_align);
|
|
|
|
break;
|
2015-11-24 11:37:35 +00:00
|
|
|
}
|
|
|
|
}
|
2018-11-22 08:46:46 +00:00
|
|
|
|
|
|
|
if (IS_ENABLED(CONFIG_ARM64_ERRATUM_843419) &&
|
|
|
|
cpus_have_const_cap(ARM64_WORKAROUND_843419))
|
|
|
|
/*
|
|
|
|
* Add some slack so we can skip PLT slots that may trigger
|
|
|
|
* the erratum due to the placement of the ADRP instruction.
|
|
|
|
*/
|
|
|
|
ret += DIV_ROUND_UP(ret, (SZ_4K / sizeof(struct plt_entry)));
|
|
|
|
|
2015-11-24 11:37:35 +00:00
|
|
|
return ret;
|
|
|
|
}
|
|
|
|
|
|
|
|
int module_frob_arch_sections(Elf_Ehdr *ehdr, Elf_Shdr *sechdrs,
|
|
|
|
char *secstrings, struct module *mod)
|
|
|
|
{
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
unsigned long core_plts = 0;
|
|
|
|
unsigned long init_plts = 0;
|
2015-11-24 11:37:35 +00:00
|
|
|
Elf64_Sym *syms = NULL;
|
2018-11-05 18:53:23 +00:00
|
|
|
Elf_Shdr *pltsec, *tramp = NULL;
|
2015-11-24 11:37:35 +00:00
|
|
|
int i;
|
|
|
|
|
|
|
|
/*
|
|
|
|
* Find the empty .plt section so we can expand it to store the PLT
|
|
|
|
* entries. Record the symtab address as well.
|
|
|
|
*/
|
|
|
|
for (i = 0; i < ehdr->e_shnum; i++) {
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
if (!strcmp(secstrings + sechdrs[i].sh_name, ".plt"))
|
2018-11-05 18:53:23 +00:00
|
|
|
mod->arch.core.plt_shndx = i;
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
else if (!strcmp(secstrings + sechdrs[i].sh_name, ".init.plt"))
|
2018-11-05 18:53:23 +00:00
|
|
|
mod->arch.init.plt_shndx = i;
|
2017-11-20 17:41:30 +00:00
|
|
|
else if (IS_ENABLED(CONFIG_DYNAMIC_FTRACE) &&
|
|
|
|
!strcmp(secstrings + sechdrs[i].sh_name,
|
|
|
|
".text.ftrace_trampoline"))
|
|
|
|
tramp = sechdrs + i;
|
2015-11-24 11:37:35 +00:00
|
|
|
else if (sechdrs[i].sh_type == SHT_SYMTAB)
|
|
|
|
syms = (Elf64_Sym *)sechdrs[i].sh_addr;
|
|
|
|
}
|
|
|
|
|
2018-11-05 18:53:23 +00:00
|
|
|
if (!mod->arch.core.plt_shndx || !mod->arch.init.plt_shndx) {
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
pr_err("%s: module PLT section(s) missing\n", mod->name);
|
2015-11-24 11:37:35 +00:00
|
|
|
return -ENOEXEC;
|
|
|
|
}
|
|
|
|
if (!syms) {
|
|
|
|
pr_err("%s: module symtab section missing\n", mod->name);
|
|
|
|
return -ENOEXEC;
|
|
|
|
}
|
|
|
|
|
|
|
|
for (i = 0; i < ehdr->e_shnum; i++) {
|
|
|
|
Elf64_Rela *rels = (void *)ehdr + sechdrs[i].sh_offset;
|
|
|
|
int numrels = sechdrs[i].sh_size / sizeof(Elf64_Rela);
|
|
|
|
Elf64_Shdr *dstsec = sechdrs + sechdrs[i].sh_info;
|
|
|
|
|
|
|
|
if (sechdrs[i].sh_type != SHT_RELA)
|
|
|
|
continue;
|
|
|
|
|
|
|
|
/* ignore relocations that operate on non-exec sections */
|
|
|
|
if (!(dstsec->sh_flags & SHF_EXECINSTR))
|
|
|
|
continue;
|
|
|
|
|
|
|
|
/* sort by type, symbol index and addend */
|
|
|
|
sort(rels, numrels, sizeof(Elf64_Rela), cmp_rela, NULL);
|
|
|
|
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
if (strncmp(secstrings + dstsec->sh_name, ".init", 5) != 0)
|
|
|
|
core_plts += count_plts(syms, rels, numrels,
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
sechdrs[i].sh_info, dstsec);
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
else
|
|
|
|
init_plts += count_plts(syms, rels, numrels,
|
arm64/kernel: don't ban ADRP to work around Cortex-A53 erratum #843419
Working around Cortex-A53 erratum #843419 involves special handling of
ADRP instructions that end up in the last two instruction slots of a
4k page, or whose output register gets overwritten without having been
read. (Note that the latter instruction sequence is never emitted by
a properly functioning compiler, which is why it is disregarded by the
handling of the same erratum in the bfd.ld linker which we rely on for
the core kernel)
Normally, this gets taken care of by the linker, which can spot such
sequences at final link time, and insert a veneer if the ADRP ends up
at a vulnerable offset. However, linux kernel modules are partially
linked ELF objects, and so there is no 'final link time' other than the
runtime loading of the module, at which time all the static relocations
are resolved.
For this reason, we have implemented the #843419 workaround for modules
by avoiding ADRP instructions altogether, by using the large C model,
and by passing -mpc-relative-literal-loads to recent versions of GCC
that may emit adrp/ldr pairs to perform literal loads. However, this
workaround forces us to keep literal data mixed with the instructions
in the executable .text segment, and literal data may inadvertently
turn into an exploitable speculative gadget depending on the relative
offsets of arbitrary symbols.
So let's reimplement this workaround in a way that allows us to switch
back to the small C model, and to drop the -mpc-relative-literal-loads
GCC switch, by patching affected ADRP instructions at runtime:
- ADRP instructions that do not appear at 4k relative offset 0xff8 or
0xffc are ignored
- ADRP instructions that are within 1 MB of their target symbol are
converted into ADR instructions
- remaining ADRP instructions are redirected via a veneer that performs
the load using an unaffected movn/movk sequence.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
[will: tidied up ADRP -> ADR instruction patching.]
[will: use ULL suffix for 64-bit immediate]
Signed-off-by: Will Deacon <will.deacon@arm.com>
2018-03-06 17:15:33 +00:00
|
|
|
sechdrs[i].sh_info, dstsec);
|
2015-11-24 11:37:35 +00:00
|
|
|
}
|
|
|
|
|
2018-11-05 18:53:23 +00:00
|
|
|
pltsec = sechdrs + mod->arch.core.plt_shndx;
|
|
|
|
pltsec->sh_type = SHT_NOBITS;
|
|
|
|
pltsec->sh_flags = SHF_EXECINSTR | SHF_ALLOC;
|
|
|
|
pltsec->sh_addralign = L1_CACHE_BYTES;
|
|
|
|
pltsec->sh_size = (core_plts + 1) * sizeof(struct plt_entry);
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
mod->arch.core.plt_num_entries = 0;
|
|
|
|
mod->arch.core.plt_max_entries = core_plts;
|
|
|
|
|
2018-11-05 18:53:23 +00:00
|
|
|
pltsec = sechdrs + mod->arch.init.plt_shndx;
|
|
|
|
pltsec->sh_type = SHT_NOBITS;
|
|
|
|
pltsec->sh_flags = SHF_EXECINSTR | SHF_ALLOC;
|
|
|
|
pltsec->sh_addralign = L1_CACHE_BYTES;
|
|
|
|
pltsec->sh_size = (init_plts + 1) * sizeof(struct plt_entry);
|
arm64: module: split core and init PLT sections
The arm64 module PLT code allocates all PLT entries in a single core
section, since the overhead of having a separate init PLT section is
not justified by the small number of PLT entries usually required for
init code.
However, the core and init module regions are allocated independently,
and there is a corner case where the core region may be allocated from
the VMALLOC region if the dedicated module region is exhausted, but the
init region, being much smaller, can still be allocated from the module
region. This leads to relocation failures if the distance between those
regions exceeds 128 MB. (In fact, this corner case is highly unlikely to
occur on arm64, but the issue has been observed on ARM, whose module
region is much smaller).
So split the core and init PLT regions, and name the latter ".init.plt"
so it gets allocated along with (and sufficiently close to) the .init
sections that it serves. Also, given that init PLT entries may need to
be emitted for branches that target the core module, modify the logic
that disregards defined symbols to only disregard symbols that are
defined in the same section as the relocated branch instruction.
Since there may now be two PLT entries associated with each entry in
the symbol table, we can no longer hijack the symbol::st_size fields
to record the addresses of PLT entries as we emit them for zero-addend
relocations. So instead, perform an explicit comparison to check for
duplicate entries.
Signed-off-by: Ard Biesheuvel <ard.biesheuvel@linaro.org>
Signed-off-by: Catalin Marinas <catalin.marinas@arm.com>
2017-02-21 22:12:57 +00:00
|
|
|
mod->arch.init.plt_num_entries = 0;
|
|
|
|
mod->arch.init.plt_max_entries = init_plts;
|
|
|
|
|
2017-11-20 17:41:30 +00:00
|
|
|
if (tramp) {
|
|
|
|
tramp->sh_type = SHT_NOBITS;
|
|
|
|
tramp->sh_flags = SHF_EXECINSTR | SHF_ALLOC;
|
|
|
|
tramp->sh_addralign = __alignof__(struct plt_entry);
|
|
|
|
tramp->sh_size = sizeof(struct plt_entry);
|
|
|
|
}
|
|
|
|
|
2015-11-24 11:37:35 +00:00
|
|
|
return 0;
|
|
|
|
}
|