mirror of
https://github.com/torvalds/linux.git
synced 2024-12-22 10:56:40 +00:00
4c9847b737
Improve the binding example by removing all the leading 0x to fix the
following dtc warnings:
Warning (unit_address_format): Node /XXX unit name should not have leading "0x"
Converted using the following command:
find Documentation/devicetree/bindings -name "*.txt" -exec sed -i -e 's/([^ ])\@0x([0-9a-f])/$1\@$2/g' {} +
This is a follow up to commit 48c926cd34
Signed-off-by: Mathieu Malaterre <malat@debian.org>
Signed-off-by: Rob Herring <robh@kernel.org>
21 lines
605 B
Plaintext
21 lines
605 B
Plaintext
* Device tree bindings for Texas Instruments keystone pll controller
|
|
|
|
The main pll controller used to drive theC66x CorePacs, the switch fabric,
|
|
and a majority of the peripheral clocks (all but the ARM CorePacs, DDR3 and
|
|
the NETCP modules) requires a PLL Controller to manage the various clock
|
|
divisions, gating, and synchronization.
|
|
|
|
Required properties:
|
|
|
|
- compatible: "ti,keystone-pllctrl", "syscon"
|
|
|
|
- reg: contains offset/length value for pll controller
|
|
registers space.
|
|
|
|
Example:
|
|
|
|
pllctrl: pll-controller@02310000 {
|
|
compatible = "ti,keystone-pllctrl", "syscon";
|
|
reg = <0x02310000 0x200>;
|
|
};
|