linux/Documentation/devicetree/bindings/clock/ti-keystone-pllctrl.txt
Mathieu Malaterre 4c9847b737 dt-bindings: Remove leading 0x from bindings notation
Improve the binding example by removing all the leading 0x to fix the
following dtc warnings:

Warning (unit_address_format): Node /XXX unit name should not have leading "0x"

Converted using the following command:

find Documentation/devicetree/bindings -name "*.txt" -exec sed -i -e 's/([^ ])\@0x([0-9a-f])/$1\@$2/g' {} +

This is a follow up to commit 48c926cd34

Signed-off-by: Mathieu Malaterre <malat@debian.org>
Signed-off-by: Rob Herring <robh@kernel.org>
2017-12-06 14:56:33 -06:00

21 lines
605 B
Plaintext

* Device tree bindings for Texas Instruments keystone pll controller
The main pll controller used to drive theC66x CorePacs, the switch fabric,
and a majority of the peripheral clocks (all but the ARM CorePacs, DDR3 and
the NETCP modules) requires a PLL Controller to manage the various clock
divisions, gating, and synchronization.
Required properties:
- compatible: "ti,keystone-pllctrl", "syscon"
- reg: contains offset/length value for pll controller
registers space.
Example:
pllctrl: pll-controller@02310000 {
compatible = "ti,keystone-pllctrl", "syscon";
reg = <0x02310000 0x200>;
};