mirror of
https://github.com/torvalds/linux.git
synced 2024-12-23 19:31:53 +00:00
9746b6e726
Cc: Eduardo Valentin <eduardo.valentin@ti.com> Cc: Zhang Rui <rui.zhang@intel.com> Signed-off-by: Javi Merino <javi.merino@arm.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
565 lines
16 KiB
C
565 lines
16 KiB
C
/*
|
|
* linux/drivers/thermal/cpu_cooling.c
|
|
*
|
|
* Copyright (C) 2012 Samsung Electronics Co., Ltd(http://www.samsung.com)
|
|
* Copyright (C) 2012 Amit Daniel <amit.kachhap@linaro.org>
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License as published by
|
|
* the Free Software Foundation; version 2 of the License.
|
|
*
|
|
* This program is distributed in the hope that it will be useful, but
|
|
* WITHOUT ANY WARRANTY; without even the implied warranty of
|
|
* MERCHANTABILITY or FITNESS FOR A PARTICULAR PURPOSE. See the GNU
|
|
* General Public License for more details.
|
|
*
|
|
* You should have received a copy of the GNU General Public License along
|
|
* with this program; if not, write to the Free Software Foundation, Inc.,
|
|
* 59 Temple Place, Suite 330, Boston, MA 02111-1307 USA.
|
|
*
|
|
* ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
|
|
*/
|
|
#include <linux/module.h>
|
|
#include <linux/thermal.h>
|
|
#include <linux/cpufreq.h>
|
|
#include <linux/err.h>
|
|
#include <linux/slab.h>
|
|
#include <linux/cpu.h>
|
|
#include <linux/cpu_cooling.h>
|
|
|
|
/**
|
|
* struct cpufreq_cooling_device - data for cooling device with cpufreq
|
|
* @id: unique integer value corresponding to each cpufreq_cooling_device
|
|
* registered.
|
|
* @cool_dev: thermal_cooling_device pointer to keep track of the
|
|
* registered cooling device.
|
|
* @cpufreq_state: integer value representing the current state of cpufreq
|
|
* cooling devices.
|
|
* @cpufreq_val: integer value representing the absolute value of the clipped
|
|
* frequency.
|
|
* @allowed_cpus: all the cpus involved for this cpufreq_cooling_device.
|
|
*
|
|
* This structure is required for keeping information of each
|
|
* cpufreq_cooling_device registered. In order to prevent corruption of this a
|
|
* mutex lock cooling_cpufreq_lock is used.
|
|
*/
|
|
struct cpufreq_cooling_device {
|
|
int id;
|
|
struct thermal_cooling_device *cool_dev;
|
|
unsigned int cpufreq_state;
|
|
unsigned int cpufreq_val;
|
|
struct cpumask allowed_cpus;
|
|
};
|
|
static DEFINE_IDR(cpufreq_idr);
|
|
static DEFINE_MUTEX(cooling_cpufreq_lock);
|
|
|
|
static unsigned int cpufreq_dev_count;
|
|
|
|
/* notify_table passes value to the CPUFREQ_ADJUST callback function. */
|
|
#define NOTIFY_INVALID NULL
|
|
static struct cpufreq_cooling_device *notify_device;
|
|
|
|
/**
|
|
* get_idr - function to get a unique id.
|
|
* @idr: struct idr * handle used to create a id.
|
|
* @id: int * value generated by this function.
|
|
*
|
|
* This function will populate @id with an unique
|
|
* id, using the idr API.
|
|
*
|
|
* Return: 0 on success, an error code on failure.
|
|
*/
|
|
static int get_idr(struct idr *idr, int *id)
|
|
{
|
|
int ret;
|
|
|
|
mutex_lock(&cooling_cpufreq_lock);
|
|
ret = idr_alloc(idr, NULL, 0, 0, GFP_KERNEL);
|
|
mutex_unlock(&cooling_cpufreq_lock);
|
|
if (unlikely(ret < 0))
|
|
return ret;
|
|
*id = ret;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* release_idr - function to free the unique id.
|
|
* @idr: struct idr * handle used for creating the id.
|
|
* @id: int value representing the unique id.
|
|
*/
|
|
static void release_idr(struct idr *idr, int id)
|
|
{
|
|
mutex_lock(&cooling_cpufreq_lock);
|
|
idr_remove(idr, id);
|
|
mutex_unlock(&cooling_cpufreq_lock);
|
|
}
|
|
|
|
/* Below code defines functions to be used for cpufreq as cooling device */
|
|
|
|
/**
|
|
* is_cpufreq_valid - function to check frequency transitioning capability.
|
|
* @cpu: cpu for which check is needed.
|
|
*
|
|
* This function will check the current state of the system if
|
|
* it is capable of changing the frequency for a given @cpu.
|
|
*
|
|
* Return: 0 if the system is not currently capable of changing
|
|
* the frequency of given cpu. !0 in case the frequency is changeable.
|
|
*/
|
|
static int is_cpufreq_valid(int cpu)
|
|
{
|
|
struct cpufreq_policy policy;
|
|
|
|
return !cpufreq_get_policy(&policy, cpu);
|
|
}
|
|
|
|
enum cpufreq_cooling_property {
|
|
GET_LEVEL,
|
|
GET_FREQ,
|
|
GET_MAXL,
|
|
};
|
|
|
|
/**
|
|
* get_property - fetch a property of interest for a give cpu.
|
|
* @cpu: cpu for which the property is required
|
|
* @input: query parameter
|
|
* @output: query return
|
|
* @property: type of query (frequency, level, max level)
|
|
*
|
|
* This is the common function to
|
|
* 1. get maximum cpu cooling states
|
|
* 2. translate frequency to cooling state
|
|
* 3. translate cooling state to frequency
|
|
* Note that the code may be not in good shape
|
|
* but it is written in this way in order to:
|
|
* a) reduce duplicate code as most of the code can be shared.
|
|
* b) make sure the logic is consistent when translating between
|
|
* cooling states and frequencies.
|
|
*
|
|
* Return: 0 on success, -EINVAL when invalid parameters are passed.
|
|
*/
|
|
static int get_property(unsigned int cpu, unsigned long input,
|
|
unsigned int *output,
|
|
enum cpufreq_cooling_property property)
|
|
{
|
|
int i;
|
|
unsigned long max_level = 0, level = 0;
|
|
unsigned int freq = CPUFREQ_ENTRY_INVALID;
|
|
int descend = -1;
|
|
struct cpufreq_frequency_table *pos, *table =
|
|
cpufreq_frequency_get_table(cpu);
|
|
|
|
if (!output)
|
|
return -EINVAL;
|
|
|
|
if (!table)
|
|
return -EINVAL;
|
|
|
|
cpufreq_for_each_valid_entry(pos, table) {
|
|
/* ignore duplicate entry */
|
|
if (freq == pos->frequency)
|
|
continue;
|
|
|
|
/* get the frequency order */
|
|
if (freq != CPUFREQ_ENTRY_INVALID && descend == -1)
|
|
descend = freq > pos->frequency;
|
|
|
|
freq = pos->frequency;
|
|
max_level++;
|
|
}
|
|
|
|
/* No valid cpu frequency entry */
|
|
if (max_level == 0)
|
|
return -EINVAL;
|
|
|
|
/* max_level is an index, not a counter */
|
|
max_level--;
|
|
|
|
/* get max level */
|
|
if (property == GET_MAXL) {
|
|
*output = (unsigned int)max_level;
|
|
return 0;
|
|
}
|
|
|
|
if (property == GET_FREQ)
|
|
level = descend ? input : (max_level - input);
|
|
|
|
i = 0;
|
|
cpufreq_for_each_valid_entry(pos, table) {
|
|
/* ignore duplicate entry */
|
|
if (freq == pos->frequency)
|
|
continue;
|
|
|
|
/* now we have a valid frequency entry */
|
|
freq = pos->frequency;
|
|
|
|
if (property == GET_LEVEL && (unsigned int)input == freq) {
|
|
/* get level by frequency */
|
|
*output = descend ? i : (max_level - i);
|
|
return 0;
|
|
}
|
|
if (property == GET_FREQ && level == i) {
|
|
/* get frequency by level */
|
|
*output = freq;
|
|
return 0;
|
|
}
|
|
i++;
|
|
}
|
|
|
|
return -EINVAL;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_cooling_get_level - for a give cpu, return the cooling level.
|
|
* @cpu: cpu for which the level is required
|
|
* @freq: the frequency of interest
|
|
*
|
|
* This function will match the cooling level corresponding to the
|
|
* requested @freq and return it.
|
|
*
|
|
* Return: The matched cooling level on success or THERMAL_CSTATE_INVALID
|
|
* otherwise.
|
|
*/
|
|
unsigned long cpufreq_cooling_get_level(unsigned int cpu, unsigned int freq)
|
|
{
|
|
unsigned int val;
|
|
|
|
if (get_property(cpu, (unsigned long)freq, &val, GET_LEVEL))
|
|
return THERMAL_CSTATE_INVALID;
|
|
|
|
return (unsigned long)val;
|
|
}
|
|
EXPORT_SYMBOL_GPL(cpufreq_cooling_get_level);
|
|
|
|
/**
|
|
* get_cpu_frequency - get the absolute value of frequency from level.
|
|
* @cpu: cpu for which frequency is fetched.
|
|
* @level: cooling level
|
|
*
|
|
* This function matches cooling level with frequency. Based on a cooling level
|
|
* of frequency, equals cooling state of cpu cooling device, it will return
|
|
* the corresponding frequency.
|
|
* e.g level=0 --> 1st MAX FREQ, level=1 ---> 2nd MAX FREQ, .... etc
|
|
*
|
|
* Return: 0 on error, the corresponding frequency otherwise.
|
|
*/
|
|
static unsigned int get_cpu_frequency(unsigned int cpu, unsigned long level)
|
|
{
|
|
int ret = 0;
|
|
unsigned int freq;
|
|
|
|
ret = get_property(cpu, level, &freq, GET_FREQ);
|
|
if (ret)
|
|
return 0;
|
|
|
|
return freq;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_apply_cooling - function to apply frequency clipping.
|
|
* @cpufreq_device: cpufreq_cooling_device pointer containing frequency
|
|
* clipping data.
|
|
* @cooling_state: value of the cooling state.
|
|
*
|
|
* Function used to make sure the cpufreq layer is aware of current thermal
|
|
* limits. The limits are applied by updating the cpufreq policy.
|
|
*
|
|
* Return: 0 on success, an error code otherwise (-EINVAL in case wrong
|
|
* cooling state).
|
|
*/
|
|
static int cpufreq_apply_cooling(struct cpufreq_cooling_device *cpufreq_device,
|
|
unsigned long cooling_state)
|
|
{
|
|
unsigned int cpuid, clip_freq;
|
|
struct cpumask *mask = &cpufreq_device->allowed_cpus;
|
|
unsigned int cpu = cpumask_any(mask);
|
|
|
|
|
|
/* Check if the old cooling action is same as new cooling action */
|
|
if (cpufreq_device->cpufreq_state == cooling_state)
|
|
return 0;
|
|
|
|
clip_freq = get_cpu_frequency(cpu, cooling_state);
|
|
if (!clip_freq)
|
|
return -EINVAL;
|
|
|
|
cpufreq_device->cpufreq_state = cooling_state;
|
|
cpufreq_device->cpufreq_val = clip_freq;
|
|
notify_device = cpufreq_device;
|
|
|
|
for_each_cpu(cpuid, mask) {
|
|
if (is_cpufreq_valid(cpuid))
|
|
cpufreq_update_policy(cpuid);
|
|
}
|
|
|
|
notify_device = NOTIFY_INVALID;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_thermal_notifier - notifier callback for cpufreq policy change.
|
|
* @nb: struct notifier_block * with callback info.
|
|
* @event: value showing cpufreq event for which this function invoked.
|
|
* @data: callback-specific data
|
|
*
|
|
* Callback to hijack the notification on cpufreq policy transition.
|
|
* Every time there is a change in policy, we will intercept and
|
|
* update the cpufreq policy with thermal constraints.
|
|
*
|
|
* Return: 0 (success)
|
|
*/
|
|
static int cpufreq_thermal_notifier(struct notifier_block *nb,
|
|
unsigned long event, void *data)
|
|
{
|
|
struct cpufreq_policy *policy = data;
|
|
unsigned long max_freq = 0;
|
|
|
|
if (event != CPUFREQ_ADJUST || notify_device == NOTIFY_INVALID)
|
|
return 0;
|
|
|
|
if (cpumask_test_cpu(policy->cpu, ¬ify_device->allowed_cpus))
|
|
max_freq = notify_device->cpufreq_val;
|
|
else
|
|
return 0;
|
|
|
|
/* Never exceed user_policy.max */
|
|
if (max_freq > policy->user_policy.max)
|
|
max_freq = policy->user_policy.max;
|
|
|
|
if (policy->max != max_freq)
|
|
cpufreq_verify_within_limits(policy, 0, max_freq);
|
|
|
|
return 0;
|
|
}
|
|
|
|
/* cpufreq cooling device callback functions are defined below */
|
|
|
|
/**
|
|
* cpufreq_get_max_state - callback function to get the max cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: fill this variable with the max cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to return the cpufreq
|
|
* max cooling state.
|
|
*
|
|
* Return: 0 on success, an error code otherwise.
|
|
*/
|
|
static int cpufreq_get_max_state(struct thermal_cooling_device *cdev,
|
|
unsigned long *state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
|
|
struct cpumask *mask = &cpufreq_device->allowed_cpus;
|
|
unsigned int cpu;
|
|
unsigned int count = 0;
|
|
int ret;
|
|
|
|
cpu = cpumask_any(mask);
|
|
|
|
ret = get_property(cpu, 0, &count, GET_MAXL);
|
|
|
|
if (count > 0)
|
|
*state = count;
|
|
|
|
return ret;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_get_cur_state - callback function to get the current cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: fill this variable with the current cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to return the cpufreq
|
|
* current cooling state.
|
|
*
|
|
* Return: 0 on success, an error code otherwise.
|
|
*/
|
|
static int cpufreq_get_cur_state(struct thermal_cooling_device *cdev,
|
|
unsigned long *state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
|
|
|
|
*state = cpufreq_device->cpufreq_state;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_set_cur_state - callback function to set the current cooling state.
|
|
* @cdev: thermal cooling device pointer.
|
|
* @state: set this variable to the current cooling state.
|
|
*
|
|
* Callback for the thermal cooling device to change the cpufreq
|
|
* current cooling state.
|
|
*
|
|
* Return: 0 on success, an error code otherwise.
|
|
*/
|
|
static int cpufreq_set_cur_state(struct thermal_cooling_device *cdev,
|
|
unsigned long state)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_device = cdev->devdata;
|
|
|
|
return cpufreq_apply_cooling(cpufreq_device, state);
|
|
}
|
|
|
|
/* Bind cpufreq callbacks to thermal cooling device ops */
|
|
static struct thermal_cooling_device_ops const cpufreq_cooling_ops = {
|
|
.get_max_state = cpufreq_get_max_state,
|
|
.get_cur_state = cpufreq_get_cur_state,
|
|
.set_cur_state = cpufreq_set_cur_state,
|
|
};
|
|
|
|
/* Notifier for cpufreq policy change */
|
|
static struct notifier_block thermal_cpufreq_notifier_block = {
|
|
.notifier_call = cpufreq_thermal_notifier,
|
|
};
|
|
|
|
/**
|
|
* __cpufreq_cooling_register - helper function to create cpufreq cooling device
|
|
* @np: a valid struct device_node to the cooling device device tree node
|
|
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
|
|
* cooling devices. It also gives the opportunity to link the cooling device
|
|
* with a device tree node, in order to bind it via the thermal DT code.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* on failure, it returns a corresponding ERR_PTR().
|
|
*/
|
|
static struct thermal_cooling_device *
|
|
__cpufreq_cooling_register(struct device_node *np,
|
|
const struct cpumask *clip_cpus)
|
|
{
|
|
struct thermal_cooling_device *cool_dev;
|
|
struct cpufreq_cooling_device *cpufreq_dev = NULL;
|
|
unsigned int min = 0, max = 0;
|
|
char dev_name[THERMAL_NAME_LENGTH];
|
|
int ret = 0, i;
|
|
struct cpufreq_policy policy;
|
|
|
|
/* Verify that all the clip cpus have same freq_min, freq_max limit */
|
|
for_each_cpu(i, clip_cpus) {
|
|
/* continue if cpufreq policy not found and not return error */
|
|
if (!cpufreq_get_policy(&policy, i))
|
|
continue;
|
|
if (min == 0 && max == 0) {
|
|
min = policy.cpuinfo.min_freq;
|
|
max = policy.cpuinfo.max_freq;
|
|
} else {
|
|
if (min != policy.cpuinfo.min_freq ||
|
|
max != policy.cpuinfo.max_freq)
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
}
|
|
cpufreq_dev = kzalloc(sizeof(struct cpufreq_cooling_device),
|
|
GFP_KERNEL);
|
|
if (!cpufreq_dev)
|
|
return ERR_PTR(-ENOMEM);
|
|
|
|
cpumask_copy(&cpufreq_dev->allowed_cpus, clip_cpus);
|
|
|
|
ret = get_idr(&cpufreq_idr, &cpufreq_dev->id);
|
|
if (ret) {
|
|
kfree(cpufreq_dev);
|
|
return ERR_PTR(-EINVAL);
|
|
}
|
|
|
|
snprintf(dev_name, sizeof(dev_name), "thermal-cpufreq-%d",
|
|
cpufreq_dev->id);
|
|
|
|
cool_dev = thermal_of_cooling_device_register(np, dev_name, cpufreq_dev,
|
|
&cpufreq_cooling_ops);
|
|
if (IS_ERR(cool_dev)) {
|
|
release_idr(&cpufreq_idr, cpufreq_dev->id);
|
|
kfree(cpufreq_dev);
|
|
return cool_dev;
|
|
}
|
|
cpufreq_dev->cool_dev = cool_dev;
|
|
cpufreq_dev->cpufreq_state = 0;
|
|
mutex_lock(&cooling_cpufreq_lock);
|
|
|
|
/* Register the notifier for first cpufreq cooling device */
|
|
if (cpufreq_dev_count == 0)
|
|
cpufreq_register_notifier(&thermal_cpufreq_notifier_block,
|
|
CPUFREQ_POLICY_NOTIFIER);
|
|
cpufreq_dev_count++;
|
|
|
|
mutex_unlock(&cooling_cpufreq_lock);
|
|
|
|
return cool_dev;
|
|
}
|
|
|
|
/**
|
|
* cpufreq_cooling_register - function to create cpufreq cooling device.
|
|
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
|
|
* cooling devices.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* on failure, it returns a corresponding ERR_PTR().
|
|
*/
|
|
struct thermal_cooling_device *
|
|
cpufreq_cooling_register(const struct cpumask *clip_cpus)
|
|
{
|
|
return __cpufreq_cooling_register(NULL, clip_cpus);
|
|
}
|
|
EXPORT_SYMBOL_GPL(cpufreq_cooling_register);
|
|
|
|
/**
|
|
* of_cpufreq_cooling_register - function to create cpufreq cooling device.
|
|
* @np: a valid struct device_node to the cooling device device tree node
|
|
* @clip_cpus: cpumask of cpus where the frequency constraints will happen.
|
|
*
|
|
* This interface function registers the cpufreq cooling device with the name
|
|
* "thermal-cpufreq-%x". This api can support multiple instances of cpufreq
|
|
* cooling devices. Using this API, the cpufreq cooling device will be
|
|
* linked to the device tree node provided.
|
|
*
|
|
* Return: a valid struct thermal_cooling_device pointer on success,
|
|
* on failure, it returns a corresponding ERR_PTR().
|
|
*/
|
|
struct thermal_cooling_device *
|
|
of_cpufreq_cooling_register(struct device_node *np,
|
|
const struct cpumask *clip_cpus)
|
|
{
|
|
if (!np)
|
|
return ERR_PTR(-EINVAL);
|
|
|
|
return __cpufreq_cooling_register(np, clip_cpus);
|
|
}
|
|
EXPORT_SYMBOL_GPL(of_cpufreq_cooling_register);
|
|
|
|
/**
|
|
* cpufreq_cooling_unregister - function to remove cpufreq cooling device.
|
|
* @cdev: thermal cooling device pointer.
|
|
*
|
|
* This interface function unregisters the "thermal-cpufreq-%x" cooling device.
|
|
*/
|
|
void cpufreq_cooling_unregister(struct thermal_cooling_device *cdev)
|
|
{
|
|
struct cpufreq_cooling_device *cpufreq_dev;
|
|
|
|
if (!cdev)
|
|
return;
|
|
|
|
cpufreq_dev = cdev->devdata;
|
|
mutex_lock(&cooling_cpufreq_lock);
|
|
cpufreq_dev_count--;
|
|
|
|
/* Unregister the notifier for the last cpufreq cooling device */
|
|
if (cpufreq_dev_count == 0)
|
|
cpufreq_unregister_notifier(&thermal_cpufreq_notifier_block,
|
|
CPUFREQ_POLICY_NOTIFIER);
|
|
mutex_unlock(&cooling_cpufreq_lock);
|
|
|
|
thermal_cooling_device_unregister(cpufreq_dev->cool_dev);
|
|
release_idr(&cpufreq_idr, cpufreq_dev->id);
|
|
kfree(cpufreq_dev);
|
|
}
|
|
EXPORT_SYMBOL_GPL(cpufreq_cooling_unregister);
|