CMDQ may fail during HNS ROCEE initialization. The following is the log
when the execution fails:
hns3 0000:bd:00.2: In reset process RoCE client reinit.
hns3 0000:bd:00.2: CMDQ move tail from 840 to 839
hns3 0000:bd:00.2 hns_2: failed to set gid, ret = -11!
hns3 0000:bd:00.2: CMDQ move tail from 840 to 839
<...>
hns3 0000:bd:00.2: CMDQ move tail from 840 to 839
hns3 0000:bd:00.2: CMDQ move tail from 840 to 0
hns3 0000:bd:00.2: [cmd]token 14e mailbox 20 timeout.
hns3 0000:bd:00.2 hns_2: set HEM step 0 failed!
hns3 0000:bd:00.2 hns_2: set HEM address to HW failed!
hns3 0000:bd:00.2 hns_2: failed to alloc mtpt, ret = -16.
infiniband hns_2: Couldn't create ib_mad PD
infiniband hns_2: Couldn't open port 1
hns3 0000:bd:00.2: Reset done, RoCE client reinit finished.
However, even if ib_mad client registration failed, ib_register_device()
still returns success to the driver.
In the device initialization process, CMDQ execution fails because HW/FW
is abnormal. Therefore, if CMDQ fails, the initialization function should
set CMDQ to a fatal error state and return a failure to the caller.