mirror of
https://github.com/torvalds/linux.git
synced 2024-12-25 12:21:37 +00:00
4dacccfac6
The commit df59fa7f4b
"spi: orion: support armada extended baud
rates" made the assumptions that all the Armada SoCs supported the
same maximum frequency. However, according the hardware datasheet, the
maximum frequency supported by the Armada 370 SoC is tclk/4, for the
Armada XP, Armada 38x and Armada 39x SoCs the limitation is 50MHz and
for the Armada 375 it is tclk/15.
This patch introduces new compatible strings to handle all these
case. In order to be future proof a compatible was created for each
SoC even if currently some SoCs seem using the same IP.
Signed-off-by: Gregory CLEMENT <gregory.clement@free-electrons.com>
Signed-off-by: Mark Brown <broonie@kernel.org>
26 lines
872 B
Plaintext
26 lines
872 B
Plaintext
Marvell Orion SPI device
|
|
|
|
Required properties:
|
|
- compatible : should be on of the following:
|
|
- "marvell,orion-spi" for the Orion, mv78x00, Kirkwood and Dove SoCs
|
|
- "marvell,armada-370-spi", for the Armada 370 SoCs
|
|
- "marvell,armada-375-spi", for the Armada 375 SoCs
|
|
- "marvell,armada-380-spi", for the Armada 38x SoCs
|
|
- "marvell,armada-390-spi", for the Armada 39x SoCs
|
|
- "marvell,armada-xp-spi", for the Armada XP SoCs
|
|
- reg : offset and length of the register set for the device
|
|
- cell-index : Which of multiple SPI controllers is this.
|
|
Optional properties:
|
|
- interrupts : Is currently not used.
|
|
|
|
Example:
|
|
spi@10600 {
|
|
compatible = "marvell,orion-spi";
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
cell-index = <0>;
|
|
reg = <0x10600 0x28>;
|
|
interrupts = <23>;
|
|
status = "disabled";
|
|
};
|