Improve the binding example by removing all the leading zeros to fix the following dtc warnings: Warning (unit_address_format): Node /XXX unit name should not have leading 0s Converted using the following command: perl -p -i -e 's/\@0+([0-9a-f])/\@$1/g' `find ./Documentation/devicetree/bindings "*.txt"` Some unnecessary changes were manually fixed. Signed-off-by: Marco Franchi <marco.franchi@nxp.com> Signed-off-by: Rob Herring <robh@kernel.org>
24 lines
652 B
Plaintext
24 lines
652 B
Plaintext
Allwinner A10 SPI controller
|
|
|
|
Required properties:
|
|
- compatible: Should be "allwinner,sun4-a10-spi".
|
|
- reg: Should contain register location and length.
|
|
- interrupts: Should contain interrupt.
|
|
- clocks: phandle to the clocks feeding the SPI controller. Two are
|
|
needed:
|
|
- "ahb": the gated AHB parent clock
|
|
- "mod": the parent module clock
|
|
- clock-names: Must contain the clock names described just above
|
|
|
|
Example:
|
|
|
|
spi1: spi@1c06000 {
|
|
compatible = "allwinner,sun4i-a10-spi";
|
|
reg = <0x01c06000 0x1000>;
|
|
interrupts = <11>;
|
|
clocks = <&ahb_gates 21>, <&spi1_clk>;
|
|
clock-names = "ahb", "mod";
|
|
#address-cells = <1>;
|
|
#size-cells = <0>;
|
|
};
|