on AT91 the timer irq is shared, so the handler might be entered without irqs being disabled. Though this should not happen as the timer irq is registered early, there have been some reports on the mailing list. To make debugging that problem easier next time it pops up a WARN_ON_ONCE is added to the handler if irqs are not off. Signed-off-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
191 lines
4.8 KiB
C
191 lines
4.8 KiB
C
/*
|
|
* at91sam926x_time.c - Periodic Interval Timer (PIT) for at91sam926x
|
|
*
|
|
* Copyright (C) 2005-2006 M. Amine SAYA, ATMEL Rousset, France
|
|
* Revision 2005 M. Nicolas Diremdjian, ATMEL Rousset, France
|
|
* Converted to ClockSource/ClockEvents by David Brownell.
|
|
*
|
|
* This program is free software; you can redistribute it and/or modify
|
|
* it under the terms of the GNU General Public License version 2 as
|
|
* published by the Free Software Foundation.
|
|
*/
|
|
#include <linux/interrupt.h>
|
|
#include <linux/irq.h>
|
|
#include <linux/kernel.h>
|
|
#include <linux/clk.h>
|
|
#include <linux/clockchips.h>
|
|
|
|
#include <asm/mach/time.h>
|
|
|
|
#include <mach/at91_pit.h>
|
|
|
|
|
|
#define PIT_CPIV(x) ((x) & AT91_PIT_CPIV)
|
|
#define PIT_PICNT(x) (((x) & AT91_PIT_PICNT) >> 20)
|
|
|
|
static u32 pit_cycle; /* write-once */
|
|
static u32 pit_cnt; /* access only w/system irq blocked */
|
|
|
|
|
|
/*
|
|
* Clocksource: just a monotonic counter of MCK/16 cycles.
|
|
* We don't care whether or not PIT irqs are enabled.
|
|
*/
|
|
static cycle_t read_pit_clk(struct clocksource *cs)
|
|
{
|
|
unsigned long flags;
|
|
u32 elapsed;
|
|
u32 t;
|
|
|
|
raw_local_irq_save(flags);
|
|
elapsed = pit_cnt;
|
|
t = at91_sys_read(AT91_PIT_PIIR);
|
|
raw_local_irq_restore(flags);
|
|
|
|
elapsed += PIT_PICNT(t) * pit_cycle;
|
|
elapsed += PIT_CPIV(t);
|
|
return elapsed;
|
|
}
|
|
|
|
static struct clocksource pit_clk = {
|
|
.name = "pit",
|
|
.rating = 175,
|
|
.read = read_pit_clk,
|
|
.shift = 20,
|
|
.flags = CLOCK_SOURCE_IS_CONTINUOUS,
|
|
};
|
|
|
|
|
|
/*
|
|
* Clockevent device: interrupts every 1/HZ (== pit_cycles * MCK/16)
|
|
*/
|
|
static void
|
|
pit_clkevt_mode(enum clock_event_mode mode, struct clock_event_device *dev)
|
|
{
|
|
switch (mode) {
|
|
case CLOCK_EVT_MODE_PERIODIC:
|
|
/* update clocksource counter */
|
|
pit_cnt += pit_cycle * PIT_PICNT(at91_sys_read(AT91_PIT_PIVR));
|
|
at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN
|
|
| AT91_PIT_PITIEN);
|
|
break;
|
|
case CLOCK_EVT_MODE_ONESHOT:
|
|
BUG();
|
|
/* FALLTHROUGH */
|
|
case CLOCK_EVT_MODE_SHUTDOWN:
|
|
case CLOCK_EVT_MODE_UNUSED:
|
|
/* disable irq, leaving the clocksource active */
|
|
at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN);
|
|
break;
|
|
case CLOCK_EVT_MODE_RESUME:
|
|
break;
|
|
}
|
|
}
|
|
|
|
static struct clock_event_device pit_clkevt = {
|
|
.name = "pit",
|
|
.features = CLOCK_EVT_FEAT_PERIODIC,
|
|
.shift = 32,
|
|
.rating = 100,
|
|
.set_mode = pit_clkevt_mode,
|
|
};
|
|
|
|
|
|
/*
|
|
* IRQ handler for the timer.
|
|
*/
|
|
static irqreturn_t at91sam926x_pit_interrupt(int irq, void *dev_id)
|
|
{
|
|
/*
|
|
* irqs should be disabled here, but as the irq is shared they are only
|
|
* guaranteed to be off if the timer irq is registered first.
|
|
*/
|
|
WARN_ON_ONCE(!irqs_disabled());
|
|
|
|
/* The PIT interrupt may be disabled, and is shared */
|
|
if ((pit_clkevt.mode == CLOCK_EVT_MODE_PERIODIC)
|
|
&& (at91_sys_read(AT91_PIT_SR) & AT91_PIT_PITS)) {
|
|
unsigned nr_ticks;
|
|
|
|
/* Get number of ticks performed before irq, and ack it */
|
|
nr_ticks = PIT_PICNT(at91_sys_read(AT91_PIT_PIVR));
|
|
do {
|
|
pit_cnt += pit_cycle;
|
|
pit_clkevt.event_handler(&pit_clkevt);
|
|
nr_ticks--;
|
|
} while (nr_ticks);
|
|
|
|
return IRQ_HANDLED;
|
|
}
|
|
|
|
return IRQ_NONE;
|
|
}
|
|
|
|
static struct irqaction at91sam926x_pit_irq = {
|
|
.name = "at91_tick",
|
|
.flags = IRQF_SHARED | IRQF_DISABLED | IRQF_TIMER | IRQF_IRQPOLL,
|
|
.handler = at91sam926x_pit_interrupt
|
|
};
|
|
|
|
static void at91sam926x_pit_reset(void)
|
|
{
|
|
/* Disable timer and irqs */
|
|
at91_sys_write(AT91_PIT_MR, 0);
|
|
|
|
/* Clear any pending interrupts, wait for PIT to stop counting */
|
|
while (PIT_CPIV(at91_sys_read(AT91_PIT_PIVR)) != 0)
|
|
cpu_relax();
|
|
|
|
/* Start PIT but don't enable IRQ */
|
|
at91_sys_write(AT91_PIT_MR, (pit_cycle - 1) | AT91_PIT_PITEN);
|
|
}
|
|
|
|
/*
|
|
* Set up both clocksource and clockevent support.
|
|
*/
|
|
static void __init at91sam926x_pit_init(void)
|
|
{
|
|
unsigned long pit_rate;
|
|
unsigned bits;
|
|
|
|
/*
|
|
* Use our actual MCK to figure out how many MCK/16 ticks per
|
|
* 1/HZ period (instead of a compile-time constant LATCH).
|
|
*/
|
|
pit_rate = clk_get_rate(clk_get(NULL, "mck")) / 16;
|
|
pit_cycle = (pit_rate + HZ/2) / HZ;
|
|
WARN_ON(((pit_cycle - 1) & ~AT91_PIT_PIV) != 0);
|
|
|
|
/* Initialize and enable the timer */
|
|
at91sam926x_pit_reset();
|
|
|
|
/*
|
|
* Register clocksource. The high order bits of PIV are unused,
|
|
* so this isn't a 32-bit counter unless we get clockevent irqs.
|
|
*/
|
|
pit_clk.mult = clocksource_hz2mult(pit_rate, pit_clk.shift);
|
|
bits = 12 /* PICNT */ + ilog2(pit_cycle) /* PIV */;
|
|
pit_clk.mask = CLOCKSOURCE_MASK(bits);
|
|
clocksource_register(&pit_clk);
|
|
|
|
/* Set up irq handler */
|
|
setup_irq(AT91_ID_SYS, &at91sam926x_pit_irq);
|
|
|
|
/* Set up and register clockevents */
|
|
pit_clkevt.mult = div_sc(pit_rate, NSEC_PER_SEC, pit_clkevt.shift);
|
|
pit_clkevt.cpumask = cpumask_of(0);
|
|
clockevents_register_device(&pit_clkevt);
|
|
}
|
|
|
|
static void at91sam926x_pit_suspend(void)
|
|
{
|
|
/* Disable timer */
|
|
at91_sys_write(AT91_PIT_MR, 0);
|
|
}
|
|
|
|
struct sys_timer at91sam926x_timer = {
|
|
.init = at91sam926x_pit_init,
|
|
.suspend = at91sam926x_pit_suspend,
|
|
.resume = at91sam926x_pit_reset,
|
|
};
|