mirror of
https://github.com/torvalds/linux.git
synced 2024-11-29 23:51:37 +00:00
54a19b4d3f
There are some ABI documents that, while they don't generate any warnings, they have issues when parsed by get_abi.pl script on its output result. Address them, in order to provide a clean output. Reviewed-by: Tom Rix <trix@redhat.com> # for fpga-manager Reviewed-By: Kajol Jain<kjain@linux.ibm.com> # for sysfs-bus-event_source-devices-hv_gpci and sysfs-bus-event_source-devices-hv_24x7 Acked-by: Jonathan Cameron <Jonathan.Cameron@huawei.com> #for IIO Acked-by: Oded Gabbay <oded.gabbay@gmail.com> # for Habanalabs Acked-by: Vaibhav Jain <vaibhav@linux.ibm.com> # for sysfs-bus-papr-pmem Acked-by: Cezary Rojewski <cezary.rojewski@intel.com> # for catpt Acked-by: Suzuki K Poulose <suzuki.poulose@arm.com> Acked-by: Ilya Dryomov <idryomov@gmail.com> # for rbd Acked-by: Jonathan Corbet <corbet@lwn.net> Signed-off-by: Mauro Carvalho Chehab <mchehab+huawei@kernel.org> Link: https://lore.kernel.org/r/5bc78e5b68ed1e9e39135173857cb2e753be868f.1604042072.git.mchehab+huawei@kernel.org Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
49 lines
1.9 KiB
Plaintext
49 lines
1.9 KiB
Plaintext
What: /sys/bus/iio/devices/iio:deviceX/in_voltageY_sensing_mode
|
|
Date: August 2015
|
|
KernelVersion: 4.2.0
|
|
Contact: source@cogentembedded.com
|
|
Description:
|
|
Program sensor type for threshold detector inputs.
|
|
Could be either "GND-Open" or "Supply-Open" mode. Y is a
|
|
threshold detector input channel. Channels 0..7, 8..15, 16..23
|
|
and 24..31 has common sensor types.
|
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_falling_value
|
|
Date: August 2015
|
|
KernelVersion: 4.2.0
|
|
Contact: source@cogentembedded.com
|
|
Description:
|
|
Channel Y low voltage threshold. If sensor input voltage goes lower then
|
|
this value then the threshold falling event is pushed.
|
|
Depending on in_voltageY_sensing_mode the low voltage threshold
|
|
is separately set for "GND-Open" and "Supply-Open" modes.
|
|
Channels 0..31 have common low threshold values, but could have different
|
|
sensing_modes.
|
|
|
|
The low voltage threshold range is between 2..21V.
|
|
Hysteresis between low and high thresholds can not be lower then 2 and
|
|
can not be odd.
|
|
|
|
If falling threshold results hysteresis to odd value then rising
|
|
threshold is automatically subtracted by one.
|
|
|
|
What: /sys/bus/iio/devices/iio:deviceX/events/in_voltageY_thresh_rising_value
|
|
Date: August 2015
|
|
KernelVersion: 4.2.0
|
|
Contact: source@cogentembedded.com
|
|
Description:
|
|
Channel Y high voltage threshold. If sensor input voltage goes higher then
|
|
this value then the threshold rising event is pushed.
|
|
Depending on in_voltageY_sensing_mode the high voltage threshold
|
|
is separately set for "GND-Open" and "Supply-Open" modes.
|
|
|
|
Channels 0..31 have common high threshold values, but could have different
|
|
sensing_modes.
|
|
|
|
The high voltage threshold range is between 3..22V.
|
|
Hysteresis between low and high thresholds can not be lower then 2 and
|
|
can not be odd.
|
|
|
|
If rising threshold results hysteresis to odd value then falling
|
|
threshold is automatically appended by one.
|