mirror of
https://github.com/torvalds/linux.git
synced 2024-10-30 00:32:38 +00:00
3d81277b65
This defines regulator platform data and board power regulator hogs for the ST-Ericsson U300 platform. Cc: Mark Brown <broonie@opensource.wolfsonmicro.com> Cc: Liam Girdwood <lrg@slimlogic.co.uk> Cc: Samuel Ortiz <sameo@linux.intel.com> Signed-off-by: Linus Walleij <linus.walleij@stericsson.com> Signed-off-by: Russell King <rmk+kernel@arm.linux.org.uk>
89 lines
2.3 KiB
C
89 lines
2.3 KiB
C
/*
|
|
* arch/arm/mach-u300/regulator.c
|
|
*
|
|
* Copyright (C) 2009 ST-Ericsson AB
|
|
* License terms: GNU General Public License (GPL) version 2
|
|
* Handle board-bound regulators and board power not related
|
|
* to any devices.
|
|
* Author: Linus Walleij <linus.walleij@stericsson.com>
|
|
*/
|
|
#include <linux/device.h>
|
|
#include <linux/signal.h>
|
|
#include <linux/err.h>
|
|
#include <linux/regulator/consumer.h>
|
|
/* Those are just for writing in syscon */
|
|
#include <linux/io.h>
|
|
#include <mach/hardware.h>
|
|
#include <mach/syscon.h>
|
|
|
|
/*
|
|
* Regulators that power the board and chip and which are
|
|
* not copuled to specific drivers are hogged in these
|
|
* instances.
|
|
*/
|
|
static struct regulator *main_power_15;
|
|
|
|
/*
|
|
* This function is used from pm.h to shut down the system by
|
|
* resetting all regulators in turn and then disable regulator
|
|
* LDO D (main power).
|
|
*/
|
|
void u300_pm_poweroff(void)
|
|
{
|
|
sigset_t old, all;
|
|
|
|
sigfillset(&all);
|
|
if (!sigprocmask(SIG_BLOCK, &all, &old)) {
|
|
/* Disable LDO D to shut down the system */
|
|
if (main_power_15)
|
|
regulator_disable(main_power_15);
|
|
else
|
|
pr_err("regulator not available to shut down system\n");
|
|
(void) sigprocmask(SIG_SETMASK, &old, NULL);
|
|
}
|
|
return;
|
|
}
|
|
|
|
/*
|
|
* Hog the regulators needed to power up the board.
|
|
*/
|
|
static int __init u300_init_boardpower(void)
|
|
{
|
|
int err;
|
|
u32 val;
|
|
|
|
pr_info("U300: setting up board power\n");
|
|
main_power_15 = regulator_get(NULL, "vana15");
|
|
if (IS_ERR(main_power_15)) {
|
|
pr_err("could not get vana15");
|
|
return PTR_ERR(main_power_15);
|
|
}
|
|
err = regulator_enable(main_power_15);
|
|
if (err) {
|
|
pr_err("could not enable vana15\n");
|
|
return err;
|
|
}
|
|
|
|
/*
|
|
* On U300 a special system controller register pulls up the DC
|
|
* until the vana15 (LDO D) regulator comes up. At this point, all
|
|
* regulators are set and we do not need power control via
|
|
* DC ON anymore. This function will likely be moved whenever
|
|
* the rest of the U300 power management is implemented.
|
|
*/
|
|
pr_info("U300: disable system controller pull-up\n");
|
|
val = readw(U300_SYSCON_VBASE + U300_SYSCON_PMCR);
|
|
val &= ~U300_SYSCON_PMCR_DCON_ENABLE;
|
|
writew(val, U300_SYSCON_VBASE + U300_SYSCON_PMCR);
|
|
|
|
/* Register globally exported PM poweroff hook */
|
|
pm_power_off = u300_pm_poweroff;
|
|
|
|
return 0;
|
|
}
|
|
|
|
/*
|
|
* So at module init time we hog the regulator!
|
|
*/
|
|
module_init(u300_init_boardpower);
|